Chongqing HOPU Filtration Plant Manufacture Co.,ltd |
|
HJT Series Fully Automatic Transformer Oil BDV Tester for 60KV ~ 80KV~ 100KV
Single Cup ,three cups, six cups
Ⅰ Introduction
HJT series fully automatic transformer oil breakdown voltage tester
is applied to test the insulating oil's dielectric strength, which
is designed as per the requirement of IEC156 Testing Method of
Insulation Oil Medium Strength, which via proper programming, has
got functions of auto boosting, step down, stirring, display and
print out. After breakdown of oil medium, HV break off will operate
within 10 seconds to enable an auto isolation of control system
partly; this effectively safeguards the personnel security and
equipment safety.
The automatic oil tester adopt industrial SCM to control, which is applied to integrate circuit, new model I/0 connection, particular testing and anti-jamming technology which largely improve the machine’s capacity .
Main features:
1.Simple operation, automatically (can be finished just press on
key)
2.Menu controlled. Input data can clear
3.Can store 99 groups’ oil testing data which is convenient to
reading and print. The testing data can keep 100 years under the
condition of power off.
4.System time can go on running under power off;
(The system time just for reference can not be the standard of
timing)
5.Can upgrade software through RS232
6.High capacity of anti-jamming and high precision of testing.
7.Small volume, light which operated in the open air very
conveniently.
8.The set shall be provided with smooth and continuous of output
voltage between zero and maximum having no distortion of waveform.
9.Audio sound and visual signal will indicate at the instant of
sample failure.
Ⅱ Technology and parameter data
1. Power Supply: 220 ±10% VAC, 50HZ
2. Output: 60 kV,70KV, 80 kV,100KV
3. Capacity: 1.2 kVA (for 60kV), 1.6 kVA (for 80 kV), 5.0 kVA (for
100 kV)
4. Pressure increase rate: About 2 KVA/S
5. Pressure testing speed: 3%
6. Break down sensitivity : <2KV
7. Wave form distortion: ≤3%
8. Time of break down: ≤10ms
9. Working environment: temperature: 0 to 40℃,
humidity: < 85% (Relative Humidity)
10. Storage environment: temperature: -20 to 60 ℃, humidity: <
75% (Relative Humidity)
11. Working Altitude: < 1500 meters. (If over 1500m, it can be
customized)
12. Test cell: Glass, volume 300 to 500 ml, with protective cover
and stirrer.
13. Electrodes: Stainless steel spherical 36 mm
diameter/hemispherical 25 mm radius, 2.5 mm gap as per IEC-156.
14. Initial stand time of oil sample: 180 seconds
Intermediate stand time of oil sample: 60 seconds
String time of oil sample: 60 seconds
Number of consecutive test: 6
15. Dimension & Weight:
Before packed: 380 × 370 × 380 mm
Net Weight: 40 KGS
After packed: 480 × 470 × 465 mm
Gross Weight: 50 KGS