Metal Mirror Surface And Coating Surface Gloss Meter HGM-B268M

Country/Region china
City & Province beijing beijing
Categories Optical Instruments
InquireNow

Product Details

Metal mirror surface and coating surface gloss meter HGM-B268M

 

  1. Reference standard and applicable scope

HGM-B268M. The gloss meter executive the ISO-2813,ISO-7668,GB8807 standard which is the high accuracy, the miniaturized gloss meter. Test with three angles of 20,60 and 85 degree of angle.

 

  1. Application

●All kinds of coating and finishing surfaces, such as paints, varnishes, printing ink, etc.
●Decorative materials, such as metal, marble, granite, polishing brick, ceramic tile and so on.
●The other kinds of materials and objects, such as plastic, woodenware, paper, etc.

 

 

3.Technical parameter

 

The technical parameters up to JJG 696 (First-level standard).

(1)display range of:0~2000(Gu)

(2)display error:0-199<2 Gu,200-2000<1% Gs

(3)angle: 20°, 60°,85°

(4)stability:<2 Gu/30min

(5)measurement spot:16×48(mm)ellipse

(6)dimension:138×36×82 (mm)

(7)power supply:4.8V (Rechargeable battery inside)

Features
1. Small and light, real easy to be carried and used.
2. 4.8V Rechargeable battery can be used for almost 60 hours and 10000 reading.
3. High stability
4. Long-term stable light source needs no replacing forever.
5. Quartz crystal standard board, no excursion.

Instructions

Press the switch equipment in the measurement mode, the instrument on the sample, the value of the samples showed that the value of the gloss (Gs). When the measurement is greater than 2000Gu, showed that "OVER" the words.

When electric quantity insufficiency demonstrated that “bAtt” the inscription, this time should with the special-purpose charging source charge, the charging source plug insert promptly to the instrument side charge plug on, duration of charging about four hours. Charge standard “⊕”, when charge on the kneading board led is lightened.

When the power is low show "bAtt" words, at this time should be used in time-specific charge rechargeable power supply, rechargeable power supply plug into sockets on the equipment side of the charge, charge time in about four hours. Charging standard "⊕", led the charge when the panels were lit.


Calibration
When the standard equipment on board and show that numerical standards board is greater than the difference between the nominal value of 1.2 gloss units, the following methods should be calibrated
Measuring instruments on the window and down the board, press the "home / home zero" key, show value for the 0.0 at this time.
A black glass plate instead of the standard black-velvet panels, measuring instruments on the window, rather than pressing the "calibration / measurement of" key, set to enter the state, showed that at this time, "000.0" and the first "0" flashes. Rather than pressing the "shift" key-flashing shifted to right, rather than pressing the "home / home zero" key "flicker" values change from 0-9-0, through pressed "shift" and "home / home zero" Made with numerical keys and display glass panels with a nominal value of the same standard, at this time rather than pressing the "calibration / measurement," the completion of key settings. Then white ceramic standard equipment on board, show value and the standard white ceramic plate with a nominal value of the error should not be greater than ± 1.2 gloss units, or else should be considered standard dirty plates. After the completion of the above-mentioned steps can be measured samples.

 

NOTE
Contents of this instrument 4 rechargeable batteries,
Package of instruments include:
Host a standard set of plates: black and white piece of the board, board zero a (standard on black velvet box), a manual, a certificate, a charger, an instrument box.

 

Standard Delivery
 

Gloss meter1pc
Instrument case1pc
Standard board

2pc

A black board is used for the highlight calibration

A white board is used for the low light calibration

Battery charger1pc
English instruction manual1pc
Calibration certificate1pc

 

HUATEC Gloss meter Reference angle for different application

AnglePoint of reference for (foreign) (China)

Application

 

 

 

 

20°

DIN-67530

ISO-2813 GB9754

ASTM-D523

ASTM-D2457 GB8807

high gloss paint, ink, plastic.

 

20°

ASTM-D1834

TAPPI-T653 GB8941.1

high gloss stencil, cast coated paper.

 

45°

ISO-2767 GB8941-2surface of aluminum and aluminum oxide.
45°

ASTM-C346 GB/T3295

ASTM-D2457 GB8807

pottery, ceramic, plastic, plastic film, Stone
45°JIS-E8741pottery, ceramic, plastic, plastic film, Stone

 

 

60°

ISO-2813 GB9754

ASTM-C584 GB9966

ASTM-D523

DIN-67530

ASTM-D2457 GB8807

Mid-gloss paint, ink, plastics, ceramics, stone.

 

 

75°

ISO-8254

TAPPI-T480 GB8941.3

copperplate paper
85°

ISO-2813 GB9754

DIN-67530

ASTM-D523

high gloss paint, ink, plastic.

 

 

Hot Products

HLT-210+ Concrete Cover Thickness Reinforcement Position Tester Features ·investigation depth could ...
HFV-700C 14x17inch Large size Industry Film Viewer The excellent selected material the viewer’s ...
Metal mirror surface and coating surface gloss meter HGM-B268M Reference standard and applicable ...
TG-5100D Real time A Scan and B Scan Through Coating Ultrasonic Thickness Gauge This ultrasonic ...
TG-3250 High Precision Thru Coating Ultrasonic Thickness Gauge TG-3250 is a high precision digital ...
TG-M69 Crawler Wall Curved Surface Climbing Thickness Measurement Robot The tracked wall climbing ...