Interlocked Fuse Protection Gas Insulated Switchgear RMU

Country/Region china
City & Province zhengzhou henan
Categories Other Chargers
InquireNow

Product Details

GB ISO 12KV Gas Insulated Switchgear Medium Voltage Ring Main Unit

Product Introduction

 

General

The Fuse switch which named F-unit is a double-position load switch with an independent grounding switch, the tripping
device and the load switch farms the load switch-fuse combination.
The Grounding switch uses double mode, which can be grounded on both sides of the fuse at the same time, thus it ensures
that the fused fuse is not charged other the earthing switch is closed. Double grounding switch is interlocked mechanically, and primary ground operates grounding of two earthing switches of the same time.
The front cover of the fuse compartment is also mechanically interlocked with the earthing switch, and only when it is founded,
the fuse can be contacted.

 

Service environment

  • Air temperature: -35℃~+40℃
  • Humidity: Monthly average 95%; Daily average 90%.
  • Altitude:≤ 1000m (Up to 5000 m can be custom)
  • Ambient air not apparently polluted by corrosive and flammable gas, vapor, etc.
  • No frequent violent shake

 

Technical Data

No.ItemUnitParameter
1Rated voltagekV122436
2Rated frequencyHz50/60
3Rated currentA630(1250*)
4

1min Power frequency

withstand voltage

wetkV385070
drykV486085
5Lightning impulse withstand voltagekV75125/150170
6Rated short circuit breaking current (peak)kA806363
7Rated active load and close circuit breaking currentA635050
8Rated transferring currentA170012001200
9Rated short circuit making a current (peak)kA806363
10Rated cable(line) charging breaking currentA

50 and 10

50/10

11Cable charge breaking current in earthing faultA202020
12Rated withstand current (peak)kA806363
13Short-time withstand current (2s)kA252020
14Mechanism lifetimes500020002000

Note: For short circuit breaking and the peak current is based on Fuse plus combination

 

Optional components:
Electric operating-AC 220/110V; DC 24/48/110/220V
Auxiliary contact 5 NO 5 NC
Full set of fuse
FTU communication interface

 

 

 

Hot Products

Fully insulated HXGN-40.5kv SF6 RMU GIS GB ISO IEC Max 1250A GB ISO 36KV Gas Fully Insulated ...
GB ISO 36KV Gas Fully Insulated Switchgear Medium Voltage Ring Main Unit Product Introduction ...
GB ISO 36KV Gas Fully Insulated Switchgear Medium Voltage Ring Main Unit Product Introduction ...
SF6 RMU HXGN15 Load Switch Module 12KV GIS GB ISO IEC Product Introduction General The load switch ...
GB ISO 12KV Gas Insulated Switchgear Medium Voltage Ring Main Unit Product Introduction General The ...
GB ISO 12KV Gas Insulated Switchgear Medium Voltage Ring Main Unit Product Introduction General VCB ...