Home Companies Knkong Electric Co.,Ltd

SF6 RMU Gas Insulated Switchgear 36KV MV GIS Switchgear

Knkong Electric Co.,Ltd
Active Member

Contact Us

[China] country

Address: No. 25 Street , Hanghai Road, Zhengzhou,Henan,China

Contact name:Ken Chan (English)

Inquir Now

Knkong Electric Co.,Ltd

SF6 RMU Gas Insulated Switchgear 36KV MV GIS Switchgear

Country/Region china
City & Province zhengzhou henan
Categories Other Roadway Products
InquireNow

Product Details

GB ISO 36KV Gas Fully Insulated Switchgear Medium Voltage Ring Main Unit

Product Introduction

 

General

The Fuse switch which named F-unit is a double-position load switch with an independent grounding switch, the tripping
device and the load switch farms the load switch-fuse combination.
The Grounding switch uses double mode, which can be grounded on both sides of the fuse at the same time, thus it ensures
that the fused fuse is not charged other the earthing switch is closed. The double grounding switch is interlocked mechanically, and primary ground operates grounding of two earthing switches of the same time.
The front cover of the fuse compartment is also mechanically interlocked with the earthing switch, and only when it is grounded,
the fuse can be contacted.

 

Service environment

  • Air temperature: -35℃~+40℃
  • Humidity: Monthly average 95%; Daily average 90%.
  • Altitude:≤ 1000m (Up to 5000 m can be custom)
  • Ambient air not apparently polluted by corrosive and flammable gas, vapor, etc.
  • No frequent violent shake

Technical Data

No.ItemUnitParameter
1Rated voltagekV122436
2Rated frequencyHz50/60
3Rated currentA630(1250*)
4

1min Power frequency

withstand voltage

wetkV385070
drykV486085
5Lightning impulse withstand voltagekV75125/150170
6Rated short circuit breaking current (peak)kA806363
7Rated active load and close circuit breaking currentA635050
8Rated transferring currentA170012001200
9Rated short circuit making a current (peak)kA806363
10Rated cable(line) charging breaking currentA

50 and 10

50/10

11Cable charge breaking current in earthing faultA202020
12Rated withstand current (peak)kA806363
13Short-time withstand current (2s)kA252020
14Mechanism lifetimes500020002000

Note: For short circuit breaking and the peak current is based on Fuse plus combination

 

 

Hot Products

GIS SF6 model HXGN15 series Switchgear 12/24/36KV 630A 1250A M.V panel GB ISO Product Introduction ...
GB ISO 36KV Gas Insulated Switchgear Medium Voltage Ring Main Unit Product Introduction General This ...
GB ISO 36KV Gas Insulated Switchgear Medium Voltage Ring Main Unit SF6 RMU HXGN15 Series 12KV GIS GB ...
Fully insulated HXGN-40.5kv SF6 RMU GIS GB ISO IEC Max 1250A GB ISO 36KV Gas Fully Insulated ...
GB ISO 36KV Gas Fully Insulated Switchgear Medium Voltage Ring Main Unit Product Introduction ...
GB ISO 36KV Gas Fully Insulated Switchgear Medium Voltage Ring Main Unit Product Introduction ...