Home Companies Hebei Pantu Machinery Equipment Co., Ltd

21Mpa Bop Blow Out Preventer API Standard Environmental Adaptation

Hebei Pantu Machinery Equipment Co., Ltd

Contact Us

[China] country

Trade Verify

Address: Xinhua District, Cangzhou City, Hebei Province, China

Contact name:Peter

Inquir Now

Hebei Pantu Machinery Equipment Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

21Mpa Bop Blow Out Preventer API Standard Environmental Adaptation

Country/Region china
City & Province cangzhou hebei
InquireNow

Product Details

21Mpa Koomey Bop Control Unit API Standard

 

Remote control distance can reach 200 meters.
The control delay time is less than 0.5 second.

Whether the BOP is open or close station can be shown real-time.
Maintenance operator should be trained professionally.
It can record curves of all kinds of pressure on the remote control panel.
 
Koomey Bop Control Unit Parameters
 

 
Item

 
Model

Number of Controlled ObjectsAccumulator SetsEffective Volume of Oil Reservoir (L)Flow Rate of PumpMotor Power (kW)Working Pressure (MPa)
Total Volume

 
(L)

Nominal Available Volume (L)Electric Pump (L/min)Pneumatic Pump (ml/stroke)
1FKQ240-3340×6 120560201651121
2FKQ320-4440×8160650201651121
3FKQ320-5540×8 160650201651121
4FKQ400-5540×10200900301651521
5FKQ400-6640×10 200900301651521
6FKQ480-5540×122401000301651521
7FKQ480-6640×12 2401000301651521
8FKQ640-6640×16320130040165×218.521
9FKQ640-7740×16 320130040165×218.521
10FKQ800-7740×20400150040165×218.521
11FKQ800-8840×20 400160040165×218.521
12FKQ960-6680×12480180040165×318.521
13FKQ960-7780×12 480180040165×318.521
14FKQ960-8880×12480180040165×318.521
15FKQ1280-8880×16 640200040×2165×318.5×221
16FKQ1280-9980×16640200040×2165×318.5×221
17FKQ1280-101080×16 640200040×2165×318.5×221
18FKDQ480-5640×122401000301651521
19FKDQ480-6640×12 2401000301651521
20FKDQ640-6640×16320130040165×218.521
21FKDQ640-7740×16 320130040165×218.521
22FKDQ800-7740×20400150040165×218.521
23FKDQ800-8840×20 400160040165×218.521
24FKDQ960-7780×12480180040165×318.521
25FKDQ960-8880×12 480180040165×318.521
26FKDQ1280-8880×16640200040×2165×318.5×221
27FKDQ1280-9980×16 640200040×2165×318.5×221
28FKDQ1280-101080×16640200040×2165×318.5×221
29FKD640-6640×16 320130040165×218.521
30FKD800-7740×20400150040165×218.521
31FKD960-8880×12 480180040165×318.521

 
Key Points of Koomey Bop Control Unit selection
To control BOP reliably and safely, oil & natural gas industry standards SY/T5053.2-2007 and APl Spec 16D should be followed when you choose and purchase a suitable product. Factors to be considered should at least be:
 

  1. Relationship between liquid volume required for closing BOP stacks and liquid volume available from the control system
  2. Requirements of pump system;
  3. Whether it needs to meet the APl 16D standards;
  4. Environmental adaptation;
  5. Special requirements on the off-shore drilling platforms.

 

 


Note:
Q:The FKQ series uses hose bundle to connect the dillr's panel with the renole control pane ,the diler operating elemerti pneumatic rotar y valves,remotecontrol panel uses cylinder to drive the 4-way 3-position vave,tis series can choose pneumatic-manual o pneumatih motor drven pressure reguiating valves,
DQ: The FKDQ series uses signal cableto connect the trller's panel with the renote contro panel ,theaillr operating e lemen is touch soreen r l ctic butonremote control panel uses cylinder to drive the 4-way 3-position valve, with pneumatic motor driven pressure regulating valves.
D: The FKD series uses signal cableto connect the drllr's panel with the remote control panel,theotrlle operating elenent is touch screen o lectic buronremote control panel uses electromagnet to drive the 4-way 3-position valve, with electromotor driven pressure regulating valves.
lf the customer want to order an APl Spec. 16D control systen, and you need to mark the APl monogram on it you need to obitain a fom named“configurationand peramelers of the bop stacks for ovder an APl Spec. 16D control system jland and surace)”from Rongsheng sales department. Afitr flng in the deti ledtechnical parameters, the Rongsheng technical department will carry out the selection calculation.
The optional device:
All series can choose BOP heating units, to heating bop in extremely cold ernvironment,ena ble the bop tofuncion normlly the BOP shouls haveheatirg ucto)FKDQ & FKD series can choose wireless remote control function.
 




















Hot Products

API 16D Koomey Bop Control Unit The BOP control system is an important piece of equipment for ...
Well Control Bop Control Unit Remote Control The accumulator unit for BOP stacks is a very important ...
API 16D Koomey Bop Control Unit Pneumatic Type Koomey Bop Control Unit introduction 1, The Remote ...
Oilfield Bop Control System Drilling Equipment The function of the Bop Control System for surface...
21Mpa Koomey Bop Control Unit API Standard Remote control distance can reach 200 meters. The control ...
Drilling Koomey Bop Control Unit Blowout Preventer Accumulator Unit The function of the Koomey Bop ...