Hunan Micomme Medical Technology Development Co., Ltd. |
|
HOSPITAL NON-INVASIVE VENTILATOR ST-30K with HFNC SOLUTION
Description
Noninvasive ventilation (NIV) supports the patient's breathing without the need for intubation or a tracheotomy. NIV delivers effective therapy with less risk of infection and improved survival in patients with respiratory failure.
Non-invasive ventilation (NIV) is ventilator support given to patients without the use of an endotracheal tube to result in the potential complications of invasive mechanical ventilation being avoided.
Application
Chronic Obstruction Pulmonary Disease: The use of non-invasive ventilation (NIV) to support patients during acute decompensated respiratory failure secondary to an exacerbation of chronic obstructive pulmonary disease has unequivocal evidence of benefit in terms of reduction in the need for intubation, length of hospital stay and mortality.
Acute respiratory distress syndrome (ARDS) is characterised by acute onset respiratory failure, diffuse pulmonary opacities and severe hypoxemia. The use of NIV can help to avoid such complications such as a higher incidence of ventilator-associated pneumonia and barotrauma.
Advantage
AST-Premium technology will monitor patients’ every single
respiration, response immediately to synchronize patients’ breath
through sensitivity trigger by detecting flow, pressure and
waveform changing.
Automatic-Sensitivity technology provide the doctor convenience no
need to set the sensitivity manually, and lower down patient’s
respiratory power.
- Trigger sensitivity: support automatic trigger and 3 levels
trigger sensitivity adjustment. The lower the trigger sensitivity
is, the less work the patient needs to do to trigger, and the
easier the ventilator is to trigger.
- Withdraw sensitivity: support automatic withdraw and 3-level
withdraw sensitivity adjustment. The lower the sensitivity, the
less work patients need to do to remove the ventilator, and the
easier it is to remove the ventilator.
6-level (100~600ms) pressure rise time, to meet the physiological needs of different flow rates at the beginning of inspiration.
The pressure is measured on mask side. The pressure measuring hose is connected to the near pressure measuring port on the left side of the machine and the tee at the lower end of the mask (inside the package of the mask) to collect the pressure in the mask.
Specifications
|