Home Companies Hunan Micomme Medical Technology Development Co., Ltd.

CE Certified 34degree Temperature High Flow Nasal Cannula Device 60A

Hunan Micomme Medical Technology Development Co., Ltd.
Active Member

Contact Us

[China] country

Address: 8, Lujing Road, High- Tech Zone, Yuelu Changsha, China

Contact name:Ellen He

Inquir Now

Hunan Micomme Medical Technology Development Co., Ltd.

CE Certified 34degree Temperature High Flow Nasal Cannula Device 60A

Country/Region china
City & Province changsha hunan
InquireNow

Product Details

CE Certified 34degree Temperature High Flow Nasal Cannula Device 60A
 
Description
High Flow Nasal Cannula (HFNC) is a heated and humidified system that allows prescribed fraction of inspired oxygen (FIO2) levels to be delivered at very high flow rates.
 
High Flow Nasal Cannula (HFNC) isn’t just a standard nasal cannula cranked up to very high flow rates. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% fio2 at flow rates of up to 70 liters/min. The flow rate and fio2 can be independently titrated based on your patient’s flow and fi02 requirements.
 
 
Application
Its use has been widely explored, particularly in ICUs and emergency departments (EDs)
 
When HFNC is used to deliver oxygen, the flow rates are much higher than can be achieved with traditional nasal cannula. This results in a greater delivery of prescribed oxygen into the lungs, and less entrainment of room air. The oxygen you want to deliver to your patients is not prone to the same effect of dilution!
 
Advantage
In the battle against Covid-19 in Wuhan in 2020, 70% high-flow device was from micomme.
 
During the pandemic, micomme provided over 7000 units of devices globally.
 
 Intelligent temperature and humidity control system

  • Providing air with core body temperature and 100% relative humidity
  • Adjustable temperature from 31℃ to 37℃

 
Effectively reduce the dead space with 60L/min high flow
 
 Unique one-way airway design, no need for disinfection, reducing equipment turnover time and the workload of medical staff.
 
  
 
Specifications

ModelOH-60A
Oxygen AdjustmentSettingManual
Range21%-100%

 
Flow

Low flow mode2-25L/min
High flow mode10-60L/min
Temperature settings31℃, 34℃,37
Real time monitoring parametersFlow, FiO2, Temperature, Treatment time

 
 
 
Data

Trend review1,3,7 days review
Content of reviewFlow, FiO2, Temperature, Treatment time
Presetting of treatment timeYes

 
 
Management

Auto reminder of maintenanceYes
Main device disinfection

No need disinfection for circuits system
Wipe disinfection for device surface

Screen4.3 inches
Dimension340*228*162mm
Weight3.3kg

 
 
 
Alarm

Tube alarm, oxygen pressure alarm, blocking alarm, water level alarm, temperature alarm, power down alarm, low ambient temperature alarm, FiO2 not reaching preset value alarm, flow not reaching preset value alarm, reaching present treatment time alarm

 




































Hot Products

Efficient high flow nasal cannula oxygen therapy device 60A Description HFNC is a simple system with ...
Micomme high flow nasal cannula device 60A Description High Flow Nasal Cannula (HFNC), isn’t just a ...
Efficient OH Series high flow nasal cannula therapy device 70C Description High-flow nasal cannula ...
Micomme high flow non-invasive respiratory therapy device 60A Description A typical HFNC system ...
CE Certified 34degree Temperature High Flow Nasal Cannula Device 60A Description High Flow Nasal ...
Micomme high flow nasal cannula device 70B Description HFNC is a heated and humidified system that ...