Micomme high flow non-invasive respiratory therapy device 60A

 

 

Description

A typical HFNC system consists of a flow generator, active heated humidifier, single-limb heated circuit, and nasal cannula.

 

High Flow Nasal Cannula (HFNC), isn’t just a standard nasal cannula cranked up to very high flow rates. It actually takes gas and can heat it to 37℃ with a 100% relative humidity and can deliver 0.21~1.00% fio2 at flow rates of up to 70 liters/min. The flow rate and fio2 can be independently titrated based on your patient’s flow and fi02 requirements.

 

 

Application

HFNC has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxemic respiratory failure such as pre-oxygenation before intubation, immunocompromised patients and acute heart failure.

 

The use of HFNC in patients with Post Surgical Respiratory Failure.

Advantage

At present, micomme occupies over 50% market share in high flow filed in China.

 

In 2020, micomme ranked the sixth in export of medical respiratory devices in China.

 

Effectively reduce the dead space with 60L/min high flow Intelligent water-controlling system, automatically refills and maintains the optimal water level in the water chamber.

 

Revolutionary trend review function, review the latest 1,3,7 days data of temperature, humidity and O2 concentration.

 

The machine uses timing function, which is convenient for nurses to charge by time.

 

 

 

 

Specifications

ParametersOH-60A
Oxygen Adjustment SettingManual
Oxygen Adjustment Range21%- 100%
Low flow mode2- 25L/min
High flow mode10- 60L/min
Temperature settings31℃,34℃,37℃
Real time display parametersPreset Flow, Preset FiO2, Preset Temperature, Treatment time
Trend review1,3,7 days review
Content of reviewFlow, FiO2, Temperature, Treatment time
Presetting of treatment timeYes
Auto reminder of maintenanceYes
Main device disinfectionNo need disinfection for circuits system
Wipe disinfection for device surface
Screen

4.3 inches

Dimension340*228*162mm
Weight3.3kg
AlarmTube alarm, oxygen pressure alarm, blocking alarm, water level alarm,
temperature alarm, power down alarm, low ambient temperature alarm,
FiO2 not reaching preset value alarm, flow not reaching preset value
alarm, reaching preset treatment time alarm

 

 

Hot Products

User-friendly high flow nasal cannula oxygen therapy device 70B Description Humidified high flow ...
Efficient high flow nasal cannula oxygen therapy device 60A Description HFNC is a simple system with ...
Micomme high flow nasal cannula device 60A Description High Flow Nasal Cannula (HFNC), isn’t just a ...
Efficient OH Series high flow nasal cannula therapy device 70C Description High-flow nasal cannula ...
Micomme high flow non-invasive respiratory therapy device 60A Description A typical HFNC system ...
CE Certified 34degree Temperature High Flow Nasal Cannula Device 60A Description High Flow Nasal ...