Shandong Haiying Wuzhou Instrument Co., Ltd. |
High-quality all-steel body Efficient refrigeration system High Speed Refrigerated Centrifuge
High Speed Refrigerated Centrifuge Features:
1. Microprocessor control, operated by touch panel, LED and LCD
display, operated data can be saved automatically, RCF value can be
set directly for working, easy to use.
2. Brushless converter motor which has high torque, super speed
bearing from Europe with high quality, smoothly running and
maintenance-free.
3. High speed refrigerated centrifuge multistage damping system, the freon-free compressor from Europe,
low noise and slight vibration,green.
4. Steel body, stainless steel centrifugal chamber, imports of key
components with high quality, durable and easy to clean.
5. High speed refrigerated centrifuge rotor identification system, overspeed, overtemperature, door
interlock, unbalanced protection. The function of rotor service
life calculation, ensure safety.
6. Pre-cooling design for chamber, fast cooling. Proprietary
SCT speed control design, fast acceleration and deceleration, high
efficiency.
7. Adjustable acceleration and deceleration from grade 0 to 9
or directly set the time of Accel/Decel, and can be store 40 kinds
of self-defining operating models, to achieve the best centrifugal
result.
8. igh speed refrigerated centrifuge hold-on and transient centrifuging, easy to centrifugal
diversification
Max RCF | 18780×g |
Max Speed | 16500r/min |
Max Capacity | 12×10mL |
Timer Range | 0-99h59min |
Temp control range | -20℃~40℃ |
Noise level | ≤60dB(A) |
Power supply | AC220V 50Hz |
What preparations need to be made before using the high-speed centrifuge?
When we use the high-speed centrifuge, we must pay attention to make some preparations in advance, so as to avoid unnecessary failures under normal operation, and to ensure the normal operation of the high-speed centrifuge or extend the service life ,details as follows:
1. We need to make sure that all the buttons on the inspection panel of the high-speed centrifuge are in the specified position and check whether the power switch is in the specified position
2. Before using the high-speed centrifuge, you also need to check whether the sample placed in each test tube is the same amount, whether the rotor is placed symmetrically, to avoid asymmetric placement or uneven weight, the entire machine is in use During the process, vibration or other problems are likely to occur.
3. During the entire operation process, you also need to pay attention to the operation according to the specifications. When using the high-speed centrifuge, put the test tube in the high-speed centrifuge in advance, tighten the screw cap, and cover the glass lid before plugging in the power supply The connector is turning on
4. According to the requirements of the speed of the sample we separated, we can directly turn to the speed we need or the required time. After the operation is completed, the speed control button needs to be rotated to the zero position and can be taken out after stopping Test tube for analysis.