Product Description

YM Seal Type CH-12 can be used in Grund fos® Pumps
JP, CH8, CH12, CRK12, CRK14, SPK1, SPK2, SPK4, SPK8, CR2,CR4 series pump, with shaft size 12mm

Products Features
Grund fos® Pumps Types
YM Seal Type CH-12 can be used in Grund fos® Pumps
For more information, please do not hesitate to contact our Technology department

 

 

 

Technical Parameters

 

 

Temperature-30℃~+200℃
pressure≤1.2Mp a
Speed≤12m/s
  

 

Materials

 

Rotary RingSIC CAR CE TC
Stationary Ring

SIC CAR CE TC

SpringSUS304/SUS316
Stationary SeatSUS304/SUS316
Secondary Seal

 VITON/EPDM

Rotary Ring HolderSUS304/SUS316

 

 

 

Preperation:
1. Shaft Outside Diameter is within tolerance +-0.05mm
2. Shaft run out <0.1mm
3. Shaf end float <0.13mm
4, No sharp edges on the shaft over the o ring


Note:
During the installation,don't scratch or damage the o ring.lf anything is damaged,please contactwith Us to replace a new one.


Installation in strucstions:
1. The full set of cartridge seal is cleaned and exactly passed leakage examine before sale.Inorder to avoid damage,don't disassemble and clean the parts again before fixing.

 

2 The fitting allowance between the seal and shaft is dl h6 0.8,and there should be leading-inedge at the end of shaft.The outside diameter of shaft at the position of screw should be 01 0.2mm smaller,resisting the screw over-tighten.Lubricate the shaft with oil

 

3. Place the cartridge seal into the pump chamber,then:
A: Tighter four screw bolts of flanges,ensuring the medium leading in hole"G"at the top Position

B : Tighter four set screws and position the shaft sleeve on the shaft.
C: Remove four gauge plates.Please keep them and they wil be used in future installation and
disassemble.
D: Connect the medium lead_in pipe with hole"G"in order to flush away the friction heat and
flushing the seal chamber when pump running.


Note:
ter complete the installation,turning the shaft by hand to check for the rotationi he shat could not rotate smoothily,seal had been improperly installed.

 

 

 

We would like lo sincerely ooperale with Clients to supply high qually products and senice We beleve in establishing a long:erm cooperalive relalionshipis lhe key to suceess

Hot Products

Technical Parameters Temperature -30℃~+180℃ pressure ≤2Mp a Speed ≤12m/s Medium Chemical raw ...
Product Description Mechanical seal for GF pumps and its standard sizes are 12mm and 16mm. Its ...
Type:Suit for Grundfos CM series pumps Replacement: AES SOS Temperature:-20℃ to +180℃ Pressure:≤1...
Technical Parameters Temperature -30℃~+180℃ pressure ≤0.8Mp a Speed ≤12m/s Medium Chemical raw ...
Grundfos Shaft SIC Mechanical Seal For Water Pump CH2-30/4-30 CH-12mm Product Description YM Seal ...
Suitable for the mechanical seal of the central air conditioning water pump in the Grundfos Paco, ...