Hematology Analyzer Reagents Horiba Abx Hematology Reagent For Pentra120 Analyzers

 

Intended Use

To be used for blood cell counting, sizing, and WBC differentiation, hemoglobin determination on ABX PENTRA120 hematology analyzers. This product is for In Vitro Diagnostic Use only.

 

APPLICABLE INSTUMENT

For use with Pentra120 hematology analyzers.

 

Specification

L-0901020Diluent-P20L
L-0206010EO-Lyse1L
L-0902010α-Lyse1L
L-0204050BA-Lyse5L
L-0903010Cleaner-P1L
L-0401005Cleaner-C500ml

 

KIT COMPOSITION

BA-Lyse

Hydrochloric Acid <0.01%, Surfactant<0.05%

EO-Lyse

Sodium Chloride <1.00%, Formic Dye <0.005%

α-Lyse

Quaternary Ammonium Salt<6.0%

Diluent-PNaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0%
Cleaner-P

Buffer<0.2%, Proteolytic Enzyme<0.3%

Cleaner-CSodium Hypochlorite

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Procedures 

  • From the run screen, press “ESC” to access the “MAIN MENU.
  • Remove the Diluent Line from the Diluent box.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Place the tubes on a dry clean place.
  • Using the arrow keys to select the menu “3-Reagents” and press “Enter”
  • From the Reagents menu, using the arrow keys to select the menu “3-Prime” and press “1-Diluent”. This step will purge the diluent lines with air to make sure that the reagents will not be mixed with the previously used ones. At this step an error message appears: “Error: NO Diluent, Check Level”
  • Press “ESC”. At this step an error message appears: “Emergency stop, Run an autocontrol”
  • Press “ESC” three times to access the Main Menu.
  • Press “4-Maintanence” – “1-Autocontrol cycle”. After the cycle has been done, press “ESC”.
  • Press “3-Reagents” – “3-Prime”
  • Remove all the lines from the bottles Cleaner, Eosinofix, Basolyse II, and Alphalyse.
  • Press “2-Cleaner”. This step will purge the Cleaner lines with air.
  • Press “3-Eosinofix”. This step will purge the Eosinofix lines with air.
  • Press “4- Basolyse II”. This step will purge the Basolyse lines with air.
  • Press “5-Alphalyse”. This step will purge the Alphalyse lines with air.
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Put all five reagent aspiration tubes into the appropriate Labnovation box and bottles.
  • Press “ESC” – “1-Level Change” – “All reagents” This step will set all reagent levels to full (100%), and an autoprime cycle will be done.
  • Press “ESC” – “Prime” – “All reagents”. Repeat this step once again.
  • After all three prime cycles have been done, press “ESC” key three times, to access the “Start Cycle” menu.
  • Run at least 5 backgrounds. Check for the acceptable values.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary. The default pathword for ABX Pentra 60 users is “123”.
Advantage
  • One source for all brands of analyzer
  • Reagents for both 3-parts and 5-parts
  • Ready-to-use final products and bulk OEM reagents
  • ISQ13485:2003 and ISO9001:2008 certified
  • CE marked, FDA cleared
  • Well-established brand used by thousands of lab in 95 countries
  • High quality, high performance and high fidelity of correlations with original brand

Storage

Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.

The open vial life of the product is 30/60 days. Unused reagents should be discarded after 30/60 days. Do not mix residual with a new carton.

L-0901020Diluent-P24 months
L-0206010EO-Lyse18 months
L-0902010α-Lyse24 months
L-0204050BA-Lyse24 months
L-0903010Cleaner-P18 months
L-0401005Cleaner-C12 months
PRECAUTIONS
  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.

FAQ

  • About MOQ?

We have the limit order which is 10000, we would like to cooperate with you, don't worry about MOQ, just send us of your what items you want order.

  • What is your lead time?

Stock 3-7 days in general. Or please contact us by email for specific lead time base on your order quantities.

  • Accept OEM or ODM order?

Yes, we accept both OEM and ODM for customers.

  • What are your terms of delivery?

We can accept EXW, FOB, CIF, etc. You can choose one which is the most convenient for you.

  • Manufacturer or Trade Company?

We're Manufacturer.

 

Hot Products

Hematology Analyzer Reagents Hycel Celly Hematology Reagent For HYCEL CELLY 18, CELLY 70 Analyzers ...
Hematology Analyzer Reagents Hycel Celly Hematology Reagent For Hycel Celly Plus Analyzers Intended ...
Hematology Analyzer Reagents Hycel Hematology Reagent Forhycel Diana5 Analyzers Intended Use To be ...
Hematology Analyzer Reagents Drew Hematology Reagent For Drew Excell22, Excell2280 Analyzers ...
Hematology Analyzer Reagents Horiba Abx Hematology Reagent For Pentra120 Analyzers Intended Use To ...
Hematology Analyzer Reagents Genius Hematology Reagent For Genius 3 Part Diff Analyzers Intended Use ...