Hematology Analyzer Reagents Hycel Celly Hematology Reagent For
Hycel Celly Plus Analyzers
Intended Use
To be used for blood cell counting, sizing, and WBC
differentiation, hemoglobin determination on Hycel Celly Plus
hematology analyzers. This product is for In Vitro Diagnostic Use
only.
APPLICABLE INSTUMENT
For use with Hycel Celly Plus hematology analyzers.
Specification
L-16003A | Plus-Pak | DILUENT 5L |
LYSE 125ML |
Cleaner 750ML |
KIT COMPOSITION
DILUENT | NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0% |
LYSE | Quaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5% |
DETERGENT | Buffer<0.3%, Proteolytic Enzyme<0.2% |
Procedures
- Remove all the reagent aspiration tubes from the currently used
reagent boxes or bottles.
- Wipe the tube’s surface with a lent free tissue, and then rinse
with distilled water.
- Put the tubes into the LABNOVATION reagent boxes or bottles.
- Run at least 50 backgrounds. Check for the acceptable values. At
first high background counts can be seen, that should lower to
normal after a few runs.
- Run all three levels of a dedicated commercial control. Check for
the acceptable values.
- Recalibrate the unit if necessary.
Advantage
- One source for all brands of analyzer
- Reagents for both 3-parts and 5-parts
- Ready-to-use final products and bulk OEM reagents
- ISQ13485:2003 and ISO9001:2008 certified
- CE marked, FDA cleared
- Well-established brand used by thousands of lab in 95 countries
- High quality, high performance and high fidelity of correlations
with original brand
Storage
L-16003A | Plus-Pak | 18 months | 30 days |
- Store the product at 5-35℃ in a dust free place with good
ventilation. Temperature outside the range may damage the product.
- The open vial life of the product is 30 days (according to the
table above). Unused reagents should be discarded after period of
validity. Do not mix residual with a new carton
-
PRECAUTIONS
- Re-calibration is recommended when changing the origin of the
reagents.
- It is not recommended using different brands of solutions together
on one unit of analyzer.
- Do not ingest. Avoid contact with skin and eyes.
- Skin contact: Flush with plenty of water.
- Eyes contact: Flush with plenty of water. Obtain immediate medical
attention.
- This kit is for professionals and in vitro diagnostic use only.
FAQ
We have the limit order which is 10000, we would like to cooperate
with you, don't worry about MOQ, just send us of your what items
you want order.
Stock 3-7 days in general. Or please contact us by email for
specific lead time base on your order quantities.
Yes, we accept both OEM and ODM for customers.
- What are your terms of delivery?
We can accept EXW, FOB, CIF, etc. You can choose one which is the
most convenient for you.
- Manufacturer or Trade Company?
We're Manufacturer.