Glycosylated Hemoglobin Detection Analyzer POCT HbA1c Analyzer Fully Automated  Analyzer

 

The Glycosylated Hemoglobin Detection Analyzer POCT HbA1c Analyzer Fully Automated Analyzer is a small, portable and fully automated point-of-care system forHbA1c test. The system delivers rapid tests of HbA1c.
The Glycosylated Hemoglobin Detection Analyzer POCT HbA1c Analyzer Fully Automated Analyzer may be used as a basic test system where the user purchases the Analyzer and manually records the results, or as an advanced system where a suite of accessories enable automatic printing of results, input of patient and operator identification numbers, and full connectivity to a PC. In this manner, the system
is highly versatile and can be tailored to specific user needs.

 


Feature

 

Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).

 

 


Reliable

IFCC calibratorNormalAbnormalNormalAbnormal
Mean HbA1c%5.49.65.39.2
CV (%)2.5%1.9%2.4%1.8%

 

 


Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English;  Abnormal alarm function.

 


Certificate

 

 

 

 

Hot Products

Automatic POCT HbA1c Analyzer For Glycosylated Hemoglobin Diaglosis Intended use This instrument is ...
Automated POCT HbA1c Analyzer For Glycated Hemoglobin Test Intended Use Automated POCT HbA1c ...
HbA1c Analyzer LD-100 POCT HbA1c Analyzer Boronate Affinity Portable Analyzer For HbA1c Intended Use ...
HbA1c Analyzer Fully Automated POCT Analyzer Detect Glycosylated Hemoglobin In Human Blood The HbA1c ...
Glycosylated Hemoglobin Detection Analyzer POCT HbA1c Analyzer Fully Automated Analyzer The ...
Fully Automated Analyzer For Glycosylated Hemoglobin Detection POCT Hba1c Test The Fully Automated ...