Variable Frequency Resonant Withstand Voltage Test Set , High Voltage Test Set For UHV Substation or GIS

 

I. Application :


This series of test system mainly aims at AC voltage withstand test of primary equipment of large capacitor and high voltage and can also satisfy field AC voltage withstand test of sorts of capacitance apparatus. HV test reactors use combined series-parallel patterns which not only meet the requirements of voltage withstand of HV transformer, GIS, SF6 breakers,mutual inductions and bushings but also that of long distance XLPE cables ,with compatibility of extensive tests to be a desired voltage withstand test device for power supply system overhauling and electric power engineer construction units.

 

The above picture is for variable series resonance test system of 5000KVA/1000KV on test field in Shanxi Jindongnan Substation, testing HV
GIS of 1000KV class UHV line in domestic.

 

Applicable objects
- Long distance XLPE cables with 110KV,220KV,500KV class
- HV GIS or GIL, HV coupling capacitor,capacitor voltage transformer of no more than 1000KV class
- Assembling capacitor(test frequency pledges in 45—65Hz)
 

 

II. Main Components:(4000KVA/1000KV test system for example)

 

SNName of ComponentsType and specificationQty.Each weightEach Dimension 
1Variable frequency powerFKVF-200kW/380V1piece180kgs750*700*1000mm
2Excitation transformerCQSB(J)-200kVA1piece1800kgs650*650*800mm
3HV resonant test reactorCHX(kf)-800kVA/200kV5pieces2800kgsD1200*H1250mm
4Capacitive dividerTRF-1000kV/1000pF1set550kgsD350*H7600mm
5Special test accessories 1set  

 

 

 

 

 

 

 

 

Note:1.Load capacitantor can be optional when small load line is tesing or need analog load to control test frequency .

2.Test reactor can be produced to be 150KV,200KV,250KV,300KV, 350KV, 400KV for each piece rated voltage according to different tested object scope or customer requried. The max. rated current of each HV reactor can be 1~15A optional in this serialized set, 

3. HV Damping inductance can be optional for suppressing  high frequency harmonics and resisting  overvoltage caused from tested object flashover, special in EHV or UHV test set.

 

III. Test priciple :
Portable Variable Frequency Resonant Withstand Voltage Test Set

VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )


IV. General Technical Data:

  1. Mode of system test: Series resonant with variable frequency
  2. System model : CHX-4000KVA/200KV,400KV,600KV, 800KV,1000KV
  3. Input power supply : 380±10%(three-phase),50Hz/60Hz
  4. Number of HV test reactor: 4pieces
  5. Rated output capacity: 4000kVA
  6. Rated output Voltage: 200KV,400KV,600KV,800KV,1000KV
  7. Max Test voltage : no more than 200KV,400KV,600KV,800KV,1000KV
  8. Rated output current: 4A /single piece or in series;16A or 20A in parallal
  9. Reg. Freq range : 20Hz-300Hz
  10. Output Resonance voltage waveform: sine wave
  11. THD of output waveform: ≤1%
  12. Insulation level: Under 1.1 times and keeping 1min, normal
  13. Duty cycle : 60mints optional on under rated current working condition ;
  14. Quality factor of test set itself: Q≥60
  15. Temperature rise: Less than 65K under rated current working withn duty cycle;
  16. Noise level: No more than 70B
  17. Reactor Structure: oil immersed type, epoxy tube cylinder type;


V. Technical Feature and advantage

  • Modular design, being able for series-parallel connection of reactors,wide range of application.
  • Operating frequency range:20-300Hz
  • High quality factor value:Q ≥ 100(when f=20Hz) large thermal capacity, low temperature rise, long
  • continuous of performance period
  • Convenient for field test for the size and weight smaller than conventional test transformers.
  • The output voltage waveform is sine wave, the waveform deviation factor ≤ 1%
  • This device can be furnished with special test vehicle and container together
  • PD free design optional.

 

 

VI.  Main Measuring and control software panel as following :


Portable Variable Frequency Resonant Withstand Voltage Test Set


VII.Accessories

  • Accessory box for storage accessoires
  • Input cables of power source
  • Output cables of power source
  • Output cables of exciting transformer
  • System grounding cables
  • Parallel cables of the reactor
  • HV measuring cables ( the signal output cables of voltage divider )
  • HV output cables(reactor to divide,divider to test object)
  • Supporting base for divider
  • Corona ring for test reactor and divider
  • A final test report, a quality Certificate ,a user manual and a packing list are offered .


VIII. Other Typical Model

 

1 For 123KV ~300KV  class GIS on-site AC hipot test

 

ModelRated voltageRated output currentRated output capacity

Application

(From 45Hz starting)

CHX-400KVA/200KV,400KV200KV*22A@200KV400KVAFor 123KV and below class GIS
1A@400KVFor 300KV and below class GIS
CHX-800KVA/200KV,400KV200KV*24A@200KV800KVAFor 123KV and below class GIS
2A@400KVFor 300KV and below class GIS
CHX-1000KVA/200KV,400KV200KV*25A@200KV1000KVAFor 123KV and below class GIS
2.5A@400KVFor 300KV and below class GIS
CHX-2000KVA/200KV,400KV200KV*210A@200KV2000KVAFor 123KV and below class GIS
5A@400KVFor 300KV and below class GIS
Special requirement can be made by order

 

2 For 145KV ~362KV class GIS on-site AC hipot test

 

ModelRated voltageRated output currentRated output capacity

Application

(From 45Hz starting)

CHX-500KVA/250KV,500KV250KV*22A@250KV500KVAFor 145KV and below class GIS
1A@500KVFor 362KV and below class GIS
CHX-1000KVA/250KV,500KV250KV*24A@250KV1000KVAFor 145KV and below class GIS
2A@500KVFor 362KV and below class GIS
CHX-2000KVA/250KV,500KV250KV*28A@250KV2000KVAFor 145KV and below class GIS
4A@500KVFor 362KV and below class GIS
CHX-3000KVA/250KV,500KV250KV*212A@250KV3000KVAFor 145KV and below class GIS
6A@500KVFor 362KV and below class GIS
Special requirement can be made by order


3 For 170KV ~550KV class GIS on-site AC hipot test

 

ModelRated voltageRated output currentRated output capacity

Application

(From 45Hz starting)

CHX-1200KVA/300KV,600KV300KV*24A@300KV1200KVAFor 170KV and below class GIS
2A@600KVFor 550KV and below class GIS
CHX-1800KVA/300KV,600KV300KV*26A@300KV1800KVAFor 170KV and below class GIS
3A@600KVFor 550KV and below class GIS
CHX-2400KVA/300KV,600KV300KV*28A@300KV2400KVAFor 170KV and below class GIS
4A@600KVFor 550KV and below class GIS
CHX-3600KVA/300KV,600KV300KV*212A@300KV3600KVAFor 170KV and below class GIS
6A@600KVFor 550KV and below class GIS
CHX-4800KVA/300KV,600KV300KV*216A@300KV4800KVAFor 170KV and below class GIS
8A@600KVFor 550KV and below class GIS
Special requirement can be made by order

 


4 For 123KV ~800KV class GIS on-site AC hipot test

 

ModelRated voltageRated output currentRated output capacity

Application

(From 45Hz starting)

CHX-2400KVA/200KV×4800KV12A@200KV2400KVAFor 123KV and below class GIS
6A@400KVFor 300KV and below class GIS
3A@600KVFor 550KV and below class GIS
3A@800KVFor 800KV and below class GIS
CHX-3600KVA/200KV×4800KV13A@200KV3600KVAFor 123KV and below class GIS
9A@400KVFor 300KV and below class GIS
4.5A@600KVFor 550KV and below class GIS
4.5A@800KVFor 800KV and below class GIS
CHX-4800KVA/200KV×4800KV24A@200KV4800KVAFor 123KV and below class GIS
12A@400KVFor 300KV and below class GIS
6A@600KVFor 550KV and below class GIS
6A@800KVFor 800KV and below class GIS
Special requirement can be made by order

 

 

IX.  On-site insulation test standard table from IEC 62271-203:2011 for HV GIS  

Variable Frequency Resonant Withstand Voltage Test Set for long HV XLPE Cable

Hot Products

Variable Frequency Resonant Withstand Voltage Test Reactor For Long HV XLPE Cable I. Application : ...
Variable Frequency Resonant Withstand Voltage Test Set , For EHV High Voltage GIS Test I. Applicatio...
Power Frequency AC Resonant Withstand Voltage Test Set , For EHV CVT and CB Rutine Testing I. ...
Power Frequency AC Resonant Withstand Voltage Test Set , Power Frequency Resonant Intelligent ...
Variable Frequency Resonant Withstand Voltage Test Set , High Voltage Test Set For UHV Substation or ...
Cable Plate Printer , Cable Lable Printer , Cable Testing Tools , Support English I. Product ...