High Buildings Vertiscape Escape Chute / Quick Home Fire Escape
Chute
Vertiscape Escape Chute Feature
1. There are 4pcs of supporting wire, which can protect breaking or
spinning of the slide;
2. Stainless steel circle can protect people;
3. Uniform speed for gliding, striking without danger, suitable for
constantly escape;
4. The escape chute can be installed on outside of building lower
than 60m;
5. Any height will be fine if the slide is installed inside room
separately;
6. Gravity principle works without electricity;
7. Installation can be segmented which is much easier to adjust
height. Connected by safety hook;
8. Escape chute can be used by all kind of people, easy to operate;
9. Person inside cannot see outside, so that even an acrophobe can
use it to escape;
10. Case can be fixed or not in room, space-saving;
11. Size can be customized.
Vertiscape Escape Chute Main technical parameters
Name: | Vertiscape Escape Chute | Entrance Circle Size: | P600mm |
---|
Distance From Landmar: | H800mm | Standard Weight: | 35-80kg |
---|
Number Of Passengers In Emergency: | 22 Person/L 20m Slide Gauge | Design Glide Speed: | ≤3.5m/s(Self Controllable) |
---|
Fire Proof Jacket High Temperature Resistance: | 600c | Experimental Tension: | 2.2t |
---|
Allowable Tension: | 1.5t | Application: | Firefighting |
---|
Escape chute type:
escape chute is the door to escape the lives of the victims in the
fire. Because opportunities are reserved for people who are
prepared. In the event of fire, there is an escape chute, and the
people in the building can escape from the scenein the first place.
According to the different building or the use of different places,
choose different types of suitable escape chute set with the
following four kinds. High rise building window escape chute
High rise building window escape chute
Outdoor type: It is usually a stainless steel storage bracket
combination box placed in the house near the window. When it is
used urgently, first open the stainless steel storage box and lift
the slide frame out of the window, then put the escape chute (cloth
bag) outlet into the room. The slide frame frame hole relies on the
slide down force, and the slide slide to the ground can complete
the evacuation of the person.
Indoor series type escape slide
Corridor, platform type escape chute: first make the house corridor
and balcony make a 75*75 cm square hole, each floor is fitted with
the floor height matching escape chute. When emergency occurs, as
long as the operating mechanism is pulled, stored in the stainless
steel storage tank in each floor of the escape chute will
automatically droop to each lower floor. Evacuate the affected
people quickly and safely from dangerous areas.
Spiral escape chute
- Indoor, outdoor, common, and mobile devices are available for
selection. No space is used to affect the original space.
- Any floor in any location can be installed within the ccc range.
- Convenient operation and rapid escape of 22 people per minute, the
weight of 35-125Kg old and weak women and children can be used.
- When using the escape slide, you will not see the scene above the
ground without fear.
- Escape chute, the outer layer is made of flame retardant material
forever, and it can delay the invasion of fire tongue when it
escapes.
- The escape chute has high safety and can withstand more than
2000Kg.
- The outer layer is affixed with luminous precautions and operating
instructions, and can be used clearly in the dark.
- The escape chute is designed according to the principle of physical
gravity, and does not need to use electricity to rely on its own
gravity.
- The escape slide adopts vertical type without occupying space, and
does not need a wide square.
Shared escape chute
The construction of a vertical outdoor smoke rush shaped channel
from the ground layer to the height of each floor, are connected in
series to form a closed fire pipe structure, each floor has a fixed
point and an escape pipe entrance box, closed at twenty-four hours
on the escape slide, and then put it directly without once there is
a fire or emergency evacuation, save time.
Mobile escape chute
For fire ladders, fire ladders to rescue when the height of the
fire scene to be specified, if the escape slide is too long, is to
save staff will be unable to find export.
Escape slide is too short, rescue staff will die. To solve this
problem, we have produced a splicing escape chute, which consists
of 3 meters,2 meters and 1 meters length slipway.