Home Companies DONGGUAN YUYANG INSTRUMENT CO., LTD

Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃ BS EN136-1998

DONGGUAN YUYANG INSTRUMENT CO., LTD

Contact Us

[China] country

Trade Verify

Address: B1505, FORTUNE PLAZA, No.1, Yuanmei Road, Nancheng District, Dongguan City, Guangdong Province, China

Contact name:Seline Yu

Inquir Now

DONGGUAN YUYANG INSTRUMENT CO., LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃ BS EN136-1998

Country/Region china
City & Province dongguan guangdong
Categories Solar Chargers
InquireNow

Product Details

BS EN136-1998 Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃

 

Description:

The Flammability test procedure evaluates the flammability of medical textiles including face masks, surgical gowns, and drapes. The test method is designed to comply with 16 CFR Part 1610. This test is required by the ASTM F2100 (Standard Specification for Performance of Materials Used in Medical Face Masks) to ensure that all face masks meet the requirements for Class 1 flammability. Testing is also required for 510(k) submissions to the FDA. In addition to the Flammability test, Nelson Labs can perform all ASTM F2100 testing.

 

 

Standard: GB 19083-2010 medical protective mask technical requirements

 

Scope:

It is the special test equipment mainly used for testing medical masks flame retardant properties.

 

Instrument Description:

The device is a mask with a head mold at a certain line speed after contact with the flame, then test the burning performance on masks.

 

Main feature:

1, PLC + touch screen control system; make test more convenient operating, visualization;

2, mask fixture for the metal body head mold, can fully simulate the actual use of the state mask.

3, the burner height can be adjustable

4, automatic timing positioning made by the burner

5, burning time, fire-retardant time are automatically recorded, show the figures.

6, with a flame temperature measurement probe, flame temperature display.

7, automatic control system, automatic ignition;

8, the burner with propane (liquefied gas) and other combustible gas interface.

9, automatic timing, automatic storage of test data; easy access to experimental reports

 

Specifications:

1, head mold automatic movement line with the speed of (60 ± 5) mm / s

2, the height of the flame can be adjusted to 40 ± 4mm

3, with a flame temperature measurement detection thermocouple

4, the flame from the top of the burner height is(20 ± 2) mm, the temperature is (800 ± 50) ℃

5. The distance between the top of the burner and the lowest point of the mask is (20 ± 2) mm

6, the burner height adjustment range of 30mm

7, metal head mold wall thickness of 2 ~ 3mm, resistant to flame burning

8, continued burning time and smoldering time timer: 0 ~ 9999.9 seconds, accuracy: ± 0.1 seconds

9, the power supply: AC220V, 50Hz, 50W

10, Weight: about 30kg

Temperature(800 ± 50) ℃

Burner Height Adjustment Range

30mm
Metal Head Mold Wall Thickness2 ~ 3mm
Time timer0 ~ 9999.9S
Accuracy± 0.1
WeightAbout 30kg

 

 

 

 

Hot Products

BS EN136-1998 Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃ Description: The Flammabilit...
100~450℃ Melt Flow Index Tester MFR MVR Thermoplastics ISO 1133 ASTM D1238 Similarities ISO 1133 and ...
100~450℃ Melt Flow Index Tester MFR MVR Thermoplastics ISO 1133 ASTM D1238 ISO 1133 Vs. ASTM D1238 ...
IEC 60332 Single Cable Vertical Flame Spread Tester Description: Single Cable Vertical Flame Spread ...
ASTM C518 Steady-State Thermal Conductivity Properties Tester by Heat Flow Meter Description: It is ...
BS EN 367 80 kW/m2 Protective Clothing Heat Transmission Tester Introduction: A new term heat ...