Home Companies DONGGUAN YUYANG INSTRUMENT CO., LTD

MFR MVR Tester Melt Flow Index Tester Equipment ASTM D1238 and ISO 1133

DONGGUAN YUYANG INSTRUMENT CO., LTD

Contact Us

[China] country

Trade Verify

Address: B1505, FORTUNE PLAZA, No.1, Yuanmei Road, Nancheng District, Dongguan City, Guangdong Province, China

Contact name:Seline Yu

Inquir Now

DONGGUAN YUYANG INSTRUMENT CO., LTD

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

MFR MVR Tester Melt Flow Index Tester Equipment ASTM D1238 and ISO 1133

Country/Region china
City & Province dongguan guangdong
Categories Other Surveillance Products
InquireNow

Product Details

 

100~450℃ Melt Flow Index Tester MFR MVR Thermoplastics ISO 1133 ASTM D1238

 

ISO 1133 Vs. ASTM D1238


ISO and ASTM offer their standards for purchase at their respective websites.
In the world of plastics, melt flow index measures the output rate -- or flow -- that occurs in natural polymer or masterbatch over the course of 10 minutes when a piston applies a fixed amount of pressure at 190 degrees Celsius. Knowing the MFI helps manufacturers asses the viscosity of a substance to better control its processing. The International Organization for Standardization's 1133 and the American Society for Testing and Material's ASTM D1238 both serve as standards for measuring melt flow index.

 

Description:


The melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) are determined by extruding molten material from the barrel of a plastometer under preset conditions of temperature and load. For melt mass-flow rate, timed segments of the extrudate are weighed and the extrudate rate is calculated in g/10 min and recorded. For melt volume-flow rate, the distance that the piston moves in a specified time or the time required for the piston to move a specified distance is measured to generate data in cm3/10 min. Melt volume-flow rate may be converted to melt mass-flow rate, or vice-versa, if the density of the material is known under the conditions of the test.
 


Standards:


ISO1133, ASTM D1238, ASTM D3364, BS2782, DIN53735, JIS K7210
 

 


Similarities

ISO 1133 and ASTM D1238 have more similarities than differences. Manufacturers consider these standards “technically equivalent,” as both detail similar standards for using an extrusion plastometer, which is commonly known as a melt indexer. Both standards present tests that measure one point on the viscosity curve under controlled conditions and both express MFI in units of grams per 10 minutes. Each standard specifies orifice length and diameter, barrel temperature and piston load ratings.

 

Methods

 

While the ISO 1133 standard requires a five-minute preheat time, ASTM D1238 requires a seven-minute preheat time. The ISO 1133 standard has a starting point of 50 mm and entails 30 mm of piston travel whereas the ASTM D1238 method has a starting point of 46 mm and entails between 6.35 and 25.4 mm of travel. Additionally, ISO and ASTM standards propose a slight dimensional difference in the piston foot of the melt indexer.

 


Features:

 

ASTM D1238 offers a variation of the melt-flow test known as a multi-weight melt flow test. This procedure -- which uses different weights of materials -- offers multiple measurements on a single charge, including measurements under varying load conditions. The ISO 1133 standard does not detail this alternative method. The ASTM standard also details recommended technical specifications for melt indexers, while ISO 1133 lacks this feature.

Procedures A and B

ISO 1133 and ASTM D1238 both offer two MFI test methods, known as Procedures A and B. Procedure A relies on a manual melt indexer making cuts at timed intervals that are then weighed on an analytical balance to determine MFI, while Procedure B features no cutting or weighing. Instead, it determines MFI via measuring a volume of extruded resin. Typically, Procedure B produces more accurate measurements as it has less opportunities for user interference. However, this procedure requires an accurate value for the resin melt density at the test temperature, while Procedure A does not require this knowledge.

 


Specifications:

 

Model YY166
Temperature range100~450
Temperature accuracy±0.5
Temperature variation in 4 hours≤0.5
Temperature variation with distance at between
10 mm and 50 mm above the die surface
≤1
Temperature Resolution0.1
Interval of temperature recovering after changing testing samplesminute≤4
Timing rangesecond0~6000
Resolution of timingsecond0.1~1
Inner diameter of diemmΦ2.095±0.005
Inner diameter of filling canistermmΦ9.550±0.025
Weights accuracy ≤±0.5%
Standard weightsg875,960,1200,1640
Possible Combination of the Standard Weightsg325, 1200, 2160, 3800, 5000
Measurement rangeg/10min0.1~100
Dimensionmm550×430×730
Power Supply 220V±10%, AC, 50HZ, 3A
Weightkg65
Cut-off device Automatic/Jog/Manual cut-off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard Accessories

 

RemarkQuantity
Main machine (with built-in control panel, micro-printer, cylinder heater, cutting knife)1 set
Piston Rod (with a stud, a piston guide)1 set
Standard die of Φ2.095±0.005mm1 set
T-Shape Weights tray1 set
5000g load Weights of 875g, 960g, 1200g, 1640g1 set for each
Die clean rod, cylinder Clean Rod, packing rod, filling funnel, feeder, wooden handle knife, cut-off blade for spare use1 set for each

 

 

 

 

 

 

 

 

 

 

 

 

Test Load

 

Load (g)Combination of dead weight (g)
325T-shape weight tray and the weight of piston
1200325+875
2160325+875+960
3800325+875+960+1640
5000325+875+960+1640+1200
10000325+875+960+1640+1200+2500+2500
21600325+875+960+1640+1200+1600+2500+2500+2500+2500+2500+2500



 

 

 

 

 

 

 

 

 

 

Hot Products

100~450℃ Melt Flow Index Tester MFR MVR Thermoplastics ISO 1133 ASTM D1238 Similarities ISO 1133 and ...
100~450℃ Melt Flow Index Tester MFR MVR Thermoplastics ISO 1133 ASTM D1238 ISO 1133 Vs. ASTM D1238 ...
IEC 60332 Single Cable Vertical Flame Spread Tester Description: Single Cable Vertical Flame Spread ...
ASTM C518 Steady-State Thermal Conductivity Properties Tester by Heat Flow Meter Description: It is ...
BS EN 367 80 kW/m2 Protective Clothing Heat Transmission Tester Introduction: A new term heat ...
AC 220V,50HZ Flooring Radiant Heat Flux Fire Testing Machine Description: This test method is used ...