ASTM C518 Steady - State Thermal Conductivity Properties Tester By Heat Flow Meter

Country/Region china
City & Province dongguan guangdong
Categories Blowers
InquireNow

Product Details

 

 

ASTM C518 Steady-State Thermal Conductivity Properties Tester by Heat Flow Meter

 

Description:

 

The popular way that using the heat flow meter to test the thermal conductivity and resistivity, together with the computer can achieve the auto inspection and report generation.

This testing method easy, quick and good repeatability, which is suitable for the heat transferring R&D of the metal materials. It can also used for the test of plastic, rubber, ceramic, glass, graphite and other heat insulating material.

 

 

Standard:

 

ISO 8301 Thermal insulation -- Determination of steady-state thermal resistance and related properties -- Heat flow meter apparatus

GB/T 10295 Thermal insulation -- Determination of steady-state thermal resistance and related properties -- Heat flow meter apparatus

ASTM C518 Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

EN 12667 Thermal performance of building materials and products - Determination of thermal resistance by means of guarded hot plate and heat flow meter methods - Products of high and medium thermal resistance;

 

 

Specification:

 

1. The area of heat conductivity: sheet sample 0.01-10W/mk, accuracy less than 3%.

2. Thermal resistance measurement: 0.1~8 m2K/W

3. Sample dimensions: 100*100mm, thickness 5 ~20mm.

4. Cold surface: 10℃~ 50℃, digital displayer to detect the temperature, 0.1 level accuracy. DPI 0.01℃.

5. Heat surface temp control: room temp.- 99.99℃, use high temp digital displayer to detect the temperature, 0.1 level accuracy. DPI 0.01 ℃. The flat type heater, two-way controllable.

6. Cold surface use water bath cooling.

7. Use computer to test automatically.

8. Use WPY heat flow meter, heat flow feature 23.26w/m2*mV.

9. Use Plexiglas’s wind cover, so that the whole test course can be observed directly.

10. Cold and hot plate heat transferring area: 150×150(mm)

11. Cold and hot plate adjustable gap distance: 0-160(mm).

 

 

Test Procedure:

 

This test uses a Heat Flow Meter Apparatus (HFM). The Heat Flow Meter consists of a cold plate and a hot plate that incorporate heat flux transducers for measuring heat flow. The material to be measured is placed between the two plates that are controlled to different temperatures to create a heat flow from hot to cold plate, which is measured by the transducers. The device is calibrated against materials of known thermal conductivity and can be used to measure flat materials in a wide range of thickness and conductivity. Tests are commonly performed with a mean temperature between 35ºF and 110ºF, with the most common being 75ºF. A temperature difference of 40ºF – 50ºF is commonly used.

 

End Result:

The thermal conductivity (k-Value) and thermal resistance (R-Value) are determined. These values can be used to determine energy losses through a material. This test can be used to satisfy R-Value regulations for insulation materials, such as the US Federal Trade Commission’s “R-Value Rule” (10 CFR 460).

 

Special Notes:

This method can often be used as an alternative to ASTM C177, which determines the same properties using a different device known as a Guarded Hot Plate Apparatus (GHP).

 

 

 

Hot Products

ISO 8301, EN 12667 Thermal Conductivity Tester of Heat Flow Meter 0.1 ~ 8.0 m2K/W Description: It is ...
100~450℃ Melt Flow Index Tester MFR MVR Thermoplastics ISO 1133 ASTM D1238 Description: The melt ...
BS EN136-1998 Medical Surgical Mask Flame Retardant Tester (800 ± 50) ℃ Description: The Flammabilit...
100~450℃ Melt Flow Index Tester MFR MVR Thermoplastics ISO 1133 ASTM D1238 Similarities ISO 1133 and ...
100~450℃ Melt Flow Index Tester MFR MVR Thermoplastics ISO 1133 ASTM D1238 ISO 1133 Vs. ASTM D1238 ...
IEC 60332 Single Cable Vertical Flame Spread Tester Description: Single Cable Vertical Flame Spread ...