Home Companies Dawnergy Technologies(Shanghai) Co., Ltd.

Fiber Optic Cable Outdoor Fiber Optic Cable ADSS

Dawnergy Technologies(Shanghai) Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: 1st Floor, A5 Building, NO.3655 SixianRd, Songjiang District, Shanghai201614China

Contact name:Peter Bi

Inquir Now

Dawnergy Technologies(Shanghai) Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Fiber Optic Cable Outdoor Fiber Optic Cable ADSS

Country/Region china
City & Province shanghai shanghai
Categories Communication Cables
InquireNow

Product Details

1. Cable cross-section

Not to scale, color is only for showing, may be not exact same as real product color

2. Cable description

Loose tube construction, tubes with jelly filled, elements (tubes and fillers if necessary) laid up around non-metallic central strength member, polyester yarns used to bind the cable core, water blocking tape, aramid yarns reinforced, 2 ripcords, and then PE outer sheath.

 

3. Fiber & tube color

3.1 Fiber color code start from No.1 Blue.

No.123456
ColorBlueOrangeGreenBrownGrayWhite
No.78 
ColorRedBlack 

3.2 Tube color code start from No.1 Blue.

No.123
ColorBlueOrangeGreen

3.3. Filler color is Natural.

4. Structure parameter

Item

Contents

Unit

Value

Fiber countNumber/24
Cable structure//1+6
Fiber No. per tubeNumber/8
Loose tubeNumber/3
Central strength memberMaterial/FRP
Cable diameter±0.5mm10.4
Cable weight±10%kg/km78
Weather condition//NESC Light
Max. span/m150
Installation sag/%≥1.0

Note: sizes and values without tolerances are nominal values.

5. Mechanical & Environmental Performance

ItemContentsValue
Max. tensile loadMAT4000 N
MOT3000 N
Max. crush resistanceShort term1500 N/100mm
Min. bending radiusInstallation20 x cable diameter
Operation10 x cable diameter
Temperature rangeOperation-20℃ ~ +70℃
Installation-10℃ ~ +60℃
Storage/transportation-20℃ ~ +70℃

6. Main mechanical & environmental performance test

Item

Test Method

Acceptance Condition

Tensile Strength

IEC 60794-1-21-E1

- Load: MAT

- Length of cable: ≥ 50m

- Load time: 1min

- Fiber strain £ 0.33%.

- Loss change £ 0.1dB@1550nm after test.

- No fiber break and no sheath damage.

- Load: MOT

- Length of cable: ≥ 50m

- Load time: 10min

- Fiber strain £ 0.05%.

- Loss change £ 0.1dB@1550nm.

- No fiber break and no sheath damage.

Crush Test

IEC 60794-1-21-E3

- Load: Short term crush

- Load time: 1min

- Loss change £ 0.1dB@1550nm after test.

- No fiber break and no sheath damage.

Torsion

IEC 60794-1-21-E7

- Length: 1m

- Twist angle: ±180°

- No. of cycle: 10

- Loss change £ 0.1dB@1550nm after test.

- No fiber break and no sheath damage.

Cable bend

IEC 60794-1-21-E11A

- Diameter of mandrel:20 x OD

- Number of turns:4

- Number of cycles:3

- Loss change £ 0.1dB@1550nm after test.

- No fiber break and no sheath damage.

Water Penetration

IEC 60794-1-22-F5

- Height of water: 1m

- Sample length: 3m

- Time: 24h

- No water leak from the cable core of the opposite end.

Temperature Cycling

IEC 60794-1-22-F1

- Temperature: -30℃~+70℃

- Time of each step: 12h

- Number of cycle: 2

- Loss change £ 0.1dB/km @1550nm.

- No fiber break and no sheath damage.

 

7. OPTICAL FIBER

ItemContentsValue
G.652D Optical characteristics
Attenuation@1310nm≤0.35dB/km
@1550nm≤0.22dB/km
Dispersion@1288nm~1339nm≤3.5ps/(nm·km)
@1550nm≤18ps/(nm·km)
Zero-Dispersion wavelength1302nm~1324nm
Zero-Dispersion slope≤0.092ps/(nm2·km)
Mode field diameter (MFD)@1310nm9.1±0.4μm
@1550nm10.4±0.5μm
Cladding diameter125.0 ± 0.7mm
Cladding non-circularity£1.0%
Core/cladding concentricity error£0.6mm
Coating diameter (uncolored)245 ± 10mm
Coating/cladding concentricity error£12mm
Cable cutoff wavelength λcc(nm)≤1260nm
Macro bending loss@1550nm (100turns;Φ60mm)≤0.05dB
Proof stress level≥100 kpsi
Link polarization dispersion (PMDQ)≤0.1ps/km1/2
Polarization mode dispersion (individual)≤0.2ps/km1/2