Home Companies Qingdao Hengfengyou Electrical Engineering Co., Ltd.

3000kVA Dry type cast resin distribution power transformer

Qingdao Hengfengyou Electrical Engineering Co., Ltd.
Active Member

Contact Us

[China] country

Address: N0.506 Huicheng Road, Chengyang District, Qingdao City,China

Contact name:Jack

Inquir Now

Qingdao Hengfengyou Electrical Engineering Co., Ltd.

3000kVA Dry type cast resin distribution power transformer

Country/Region china
City & Province qingdao shandong
InquireNow

Product Details

Dry type transformer

SCB Dry Type power distribution transformer

 

SC(B)10, SC(B)11, SC(B)13 are the typical dry epoxy distribution power transformer, they are fireproof, compact and mainly designed for indoor use, and can be directly installed in the load center.

 

Dry transformers with high and low voltage windings are coated by a thin layer of epoxy resin. It has the advantages of flame retardant, self-extinguishing, moisture-proof, heat dissipation and so on. It can go deep into load centers, such as high-rise buildings, airports, wharfs, power plants, residential communities or complete sets of substations.


The company's products are mainly used for power transmission and transmission frequency of 50HZ, power network voltage of 10KV or 35KV, and the transmission and distribution of altitudes of 1000 meters and below. It can be used as power supply for rural and regional power supply and rural water drainage and drainage, outdoor installation, continuous use. With reliable technology, high-quality materials, good economic performance, good reputation and excellent service, our products have won unanimous praise from new and old customers.

 

Benefits:
1. Low noisy
2. Low partial discharge
3. High mechanical strength and strong short circuit resistance ability;
4. Strong impact resistance


Application
SC(B) Series DRY EPOXY RESIN DISTRIBUTION POWER TRANSFORMER is widely applied in hotels, high buildings, business centers, residence community, gymnasium, Petrochemical plant, airport, harbor, metro, mine, drillic.

 

Technical data

 

Type

Rated

capacity

(KVA)

Connection

groupgrade

Voltagecombination(KV)

Noloadloss

(W)

loadloss(W)

DyYy

No-load

current(%)

Short-circuit

resistance(%)

HighvoltageTappingrangeLowvoltage
SC12-3030

YynO

.

Dyn11

10

6.3

6

土5%

+2x2.5%

+x2.5%

0.41507102.34.0
SC12-505021510002.2
SC12-808029513801.7
SC12-10010032015701.7
SC12-12512537518501.5
SC(B)12-16016043021301.5
SC(B)12-20020049525301.3
SC(B)12-25025057527601.3
SC(B)12-31531570534701.1
SC(B)12--40040078539901.1
SC(B)12-50050093048801.1
SC(B)12-630630107058800.9
SC(B)12-630630104059600.9 
SC(B)12-800800121569600.9
SC(B)12-10001000141581300.9
SC(B)12-12501250167096900.9
SC(B)12-160016001960117300.9
SC(B)12-200020002440144500.7
SC(B)12-250025002880171700.7

 

 

Product details

 

 

Low loss:the product no-load loss is 20% lower than the Sc (B) 11 type product with an  excellent energysaving effect, economic efficient operation and without maintenance.

Low noise:the product noise level is 10-15 db lower than the existing professional standard
 JB/T10088- 2004Sound Level of 6- -220KV Transformer

Low partial discharge:resin mixture adopts foreign leading-edge mixing method and film type
 vacuumdeaerator to evenly mix the mixture and remove the bubble in the bottom part of mixture.

The product  low partial discharge which can be controlled at 5PC. Both high voltage and low voltage coils can bepoured in vacuum pressure so as to enable a encapsulating of resin insulation  and immersion amonglayers and inter-tums. The poured part has a compact solidity staicture with  anti-flaming, anti explosionand environmental protection features. Glass fiber and other raw materials of winding coil have self- extinguishing property and will not  producearc due to short circuit. Resin will not produce harmful gas under high temperature.

 

Points to note

 

1.working condition

* Device types: indoor type

* Normal environment conditions of use: the elevation not more than 1000 m

* Environmental highest temperature + 40℃, minimum-25 ℃

* The special environment conditions of use: elevation of more than 1000 m

* Environmental highest temperature + 40 ℃, minimum-45 ℃. (when you order details)

* Mounting ambicnt: no corrosive gas, no obvious dirt environment

 

2.applicable  standard

* IEC60076 power transformer

* IEC723 dry power transformer

* GB6450-1986 dry power transformer

* GB/R1094-1996 power transformer

* GB4208-1993 outer shell protect grade(IP code)

 

 

Qualification Centre

 

All products of the company have passed the national type test like CCC, CQC , CTQC and other

national mandatory product certification, and has a perfect quality, occupational health and

environmental management system certification system. Our products have passed ISO9001, 2000

and other international quality system certification.

 

 

 

 

SCOPE of application

 

None of the dry-type transformers we see today are installed in a separate, tightly enclosed room, as in

the oil-immersed type, but only in a relatively dry and clean room. In addition to this, it is also very convenient

to transport or carry, no matter what kind of transport vehicles, trains, cars or other non-motor vehicles can be,

but it is best to keep the car dry, clean and the product itself in good packaging. Practice has proved that really

good products will always be more and more marketable. As dry-type transformers have very good fire-proof

performance and are easy to install and maintain, they are also used more and more widely Especially in the

modern commercial downtown, residential areas, hospitals, airports, stations, subways, theaters, schools,

public places and other places with high requirements on fire protection.

 

 

 

 

Hot Products

Dry type transformer Features SG10 transformer has no flammable resin, and it does not support ...
Dry type transformer SCB Dry Type power transformer The reel core fully sealed distribution ...
Dry type transformer SCB Dry Type power transformer The reel core fully sealed distribution ...
Dry type transformer SCB Dry Type power distribution transformer SC(B)10, SC(B)11, SC(B)13 are the ...
Dry type transformer SCB Dry Type power distribution transformer With advanced design and manufactur...
Dry type transformer SCB Dry Type power distribution transformer Overview & features SCB epoxy resin ...