Product name: Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space

 

ECG SERIES COMMERCIAL DUAL-DISCHARGE GLYCOL UNIT COOLERS

 

1. Product description:

ECG series air coolers are designed with ethylene glycol solution as secondary coolant and ultra-thin structure, with air inlet from the bottom and air outlet from two sides. ECG series coolers are mainly used in cold storage that use ethylene glycol solution as secondary coolant. The product has a small installation space and is mainly used in a manned processing room with low temperature glycol solution as the secondary refrigerant. ECG series coolers can be used at 10℃, 0℃ and -18℃ respectively.

This series of products have the following characteristics:

● Casing: Al-Mg alloy sheet with silver powder coating (RAL7001) , it has strong anti-corrosion property and light weight.

● Evaporator end plate adopts aluminum plate, effectively protect copper tube, reduce weight.

● Double water plate design: the outer water plate with hinge structure design, convenient operation; The inner water tray adopts the flume structure of aluminum plate. The condensed water or defrosted water is directly discharged into the outlet of the outer water tray through the inner water tray.

● Coil:copper pipe φ12, the tube spacing is 38.1×33 ,triangle arrangement, heat transfer efficiency is high.

● Corrugated aluminum fins with hydrophilic film, fin spacing of 4.0 and 6.0mm to meet the different temperature requirements of cold storage.

● Fans:external rotor fan, fan specification φ350, working temperature -30~60℃, the number of fans 1 to 4. With high speed and low speed design, can meet different noise requirements.

● Defrosting:standard electric heating defrosting, stainless steel heating pipe are distributed on the coil tube fin and inner water plate, has a good defrosting effect.

● IP65 grade waterproof junction box and waterproof connector, the fan and heating pipe adopt independent wire box ,with better waterproof effect, high reliability.

● The outlet of the air cooler is equipped with schrader alve, which is convenient for users to detect pressure.

● Strict factory pressure test, test pressure 23bar.

 

2. Standard configuration and options:

PartsConfigurationPartsConfiguration
CasingAl-Mg alloy sheet with powder coatingFinAluminum fins
sheet with powder coatingHydrophilic aluminum fins
Galvanized sheet with powder coatingDefrostingAir defrosting
Stainless steel plateElectric heating pipe
FanWEIGUANG motorWater×
EBM motorDrainpipe hot wire
The wind bucket motor×Wind duct heating belt×

●:Standard;○:Options;×:Do not choose

 

3. Technical data sheet:

3.1 Fan standard speed(1420rpm)

3.1.1 Fin spacing 4.0mm

Model

Glycol 25%

T1=-3, T2=2

Tr=10,RH85%

Glycol 34%

T1=-10, T2=-7

Tr=0,RH85%

Surface

Tube

Volume

AirflowAirthrowConnect pipeWeight
Capacity (KW)

Liquid Flow

(m3/h)

Capacity (KW)

Liquid Flow

(m3/h)

m2dm3m3/hmInletOutletDrainkg
ECG351/CLN-ET3.50.62.60.813.12.522006φ22φ22G1”31
ECG351/DLN-ET4.40.83.21.017.53.420006φ22φ22G1”33
ECG352/CLN-ET7.11.35.11.626.34.744008φ28φ28G1”51
ECG352/DLN-ET8.81.66.32.035.06.340008φ28φ28G1”55
ECG353/CLN-ET10.62.07.72.539.46.9660010φ28φ28G1”73
ECG353/DLN-ET13.12.49.43.052.59.2600010φ35φ35G1”79
ECG354/CLN-ET14.22.610.23.352.59.1880012φ35φ35G1”93
ECG354/DLN-ET17.53.212.64.070.012.2800012φ35φ35G1”100

In the table, T1 is the inlet temp. of ethylene glycol solution, T2 is the outlet temp., and Tr is the temp. of cold room.

 

3.1.2 Fin spacing 6.0mm

Model

Glycol 34%

T1=-10, T2=-7

Tr=0,RH85%

Glycol 50%

T1=-28,T2=-25

Tr=-18,RH95%

Surface

Tube

Volume

AirflowAirthrowConnect pipeWeight
Capacity (KW)

Liquid Flow

(m3/h)

Capacity (KW)

Liquid Flow

(m3/h)

m2dm3m3/hmInletOutletDrainkg
ECG351/CDN-ET2.10.71.90.79.02.523506φ22φ22G1”30
ECG351/DDN-ET2.60.82.40.812.03.422006φ22φ22G1”32
ECG352/CDN-ET4.31.43.91.418.14.747008φ28φ28G1”50
ECG352/DDN-ET5.31.74.81.724.16.344008φ28φ28G1”53
ECG353/CDN-ET6.42.05.82.027.16.9705010φ28φ28G1”71
ECG353/DDN-ET7.92.57.22.536.19.2660010φ35φ35G1”76
ECG354/CDN-ET8.52.77.82.736.19.1940012φ35φ35G1”91
ECG354/DDN-ET10.63.49.63.448.212.2880012φ35φ35G1”97

In the table, T1 is the inlet temp. of ethylene glycol solution, T2 is the outlet temp., and Tr is the temp. of cold room.

 

3.2 Fan low speed(920rpm)

3.2.1 Fin spacing 4.0mm

Model

Glycol 25%

T1=-3, T2=2

Tr=10,RH85%

Glycol 34%

T1=-10, T2=-7

Tr=0,RH85%

Surface

Tube

Volume

AirflowAirthrowConnect pipeWeight
Capacity (KW)

Liquid Flow

(m3/h)

Capacity (KW)

Liquid Flow

(m3/h)

m2dm3m3/hmInletOutletDrainkg
ECG351/CLS-ET2.90.51.80.613.12.511505φ22φ22G1”31
ECG351/DLS-ET3.50.62.10.717.53.413005φ22φ22G1”33
ECG352/CLS-ET5.81.13.71.226.34.723007φ28φ28G1”51
ECG352/DLS-ET7.01.34.21.335.06.326007φ28φ28G1”55
ECG353/CLS-ET8.71.65.51.839.46.934508φ28φ28G1”73
ECG353/DLS-ET10.51.96.32.052.59.239008φ35φ35G1”79
ECG354/CLS-ET11.62.17.42.452.59.1460010φ35φ35G1”93
ECG354/DLS-ET14.02.68.42.770.012.2520010φ35φ35G1”100

In the table, T1 is the inlet temp. of ethylene glycol solution, T2 is the outlet temp., and Tr is the temp. of cold room.

 

3.2.2 Fin spacing 6.0mm

Model

Glycol 34%

T1=-10, T2=-7

Tr=0,RH85%

Glycol 50%

T1=-28,T2=-25

Tr=-18,RH95%

Surface

Tube

Volume

AirflowAirthrowConnect pipeWeight
Capacity (KW)

Liquid Flow

(m3/h)

Capacity (KW)

Liquid Flow

(m3/h)

m2dm3m3/hmInletOutletDrainkg
ECG351/CDS-ET1.50.51.30.59.02.513005φ22φ22G1”30
ECG351/DDS-ET1.80.61.60.612.03.414505φ22φ22G1”32
ECG352/CDS-ET3.11.02.71.018.14.726007φ28φ28G1”50
ECG352/DDS-ET3.61.23.11.224.16.329007φ28φ28G1”53
ECG353/CDS-ET4.61.54.11.527.16.939008φ28φ28G1”71
ECG353/DDS-ET5.41.74.71.736.19.243508φ35φ35G1”76
ECG354/CDS-ET6.12.05.42.036.19.1520010φ35φ35G1”91
ECG354/DDS-ET7.22.36.32.348.212.2580010φ35φ35G1”97

In the table, T1 is the inlet temp. of ethylene glycol solution, T2 is the outlet temp., and Tr is the temp. of cold room.

 

4. Electrical parameter table:

ModelFan MotorElectric defrosting
Voltage(V)Input(W)Current(A)Speed(r/min)Coil(KW)Tray(KW)Total(KW)
ECG351/**N-ET380-31650.4314202×0.62×0.62.4
ECG352/**N-ET380-33300.8614202×1.12×1.14.4
ECG353/**N-ET380-34951.2914202×1.62×1.66.4
ECG354/**N-ET380-36601.7214202×2.02×2.08.0
ECG351/**S-ET380-3800.329202×0.62×0.62.4
ECG352/**S-ET380-31600.649202×1.12×1.14.4
ECG353/**S-ET380-32400.969202×1.62×1.66.4
ECG354/**S-ET380-33201.289202×2.02×2.08.0

 

5.How to select correct evaparator:

Generally,Choose evaporator capacity=cold room cooling capacity *1.15

1.When the cold room temperature is around 0℃, select 4.5mm as fin space.

Evaporator choose=1.0*Q0

2.When the cold room temperature is around -18℃, select 6mm as fin space.

Evaparator choose=1.1*Q0

3.When the cold room temperature is around -25℃, select 9mm as fin space.

Evaparator choose=1.27*Q0

Remarks: The water defrost and hot gas defrost type are also optional.

Customized specification leave me message for details.

 

6.Want to know other related products?-click picture for detailed specification

 

 

 

7.How to assure quality? Any procedure?

Our QC department will make sure of each step

 

8.Do you factory?
We are factory established in 1995 and through 28years developed,welcomed by all our customers.Because of all your support now we are a big family of more than 300 people,covered 50000 square meters,and your supporting is very important of continuing our dream of eating fresh and healthy food.

 

 

9.Do you attend exhibition?

Each year we will attend domestic national and foreign exhibition,also we will support our agent to attend exhibition,welcome to join us.

 

10.Why choose us

Professional:28 years focus one thing-refrigeration equipments

Material we use sufficient

Certificate:CE, ISO, and cetiifcate of producing special pressure equipment

 

 

11.Projects reference?

 

12.FAQ

1, Q:Where is your factory address?

A:We are factory and located in refrigeration equipment producing base Shengzhou,Zhejiang province.

 

2, Q: What is your package?

A: Our package comply to custom require not include original wood.

 

3, Q:What is your MOQ?

A: Ordinary products can order from 1 set.

 

4, Q: Can you offer sample?

A: Yes,we can offer sample.and cost and delivery at your charge.

 

5, Q:I can't find products on your list?

A: Please contact me directly.

 

6,Q:How can i confirm your factory?

A: We have third party verified document of Bureau Veritas report,you can download in company page or leave me message to get.

 

 

Hot Products

Product name:ISO9001 Aluminum Coolroom Evaporator Cooling Unit For Cold Room EL SERIES INDUSTRIAL ...
Product name: Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw EF SERIES GROUND...
Product name: Fridge Coolroom Evaporator Unit Coolers With Water Defrosting​ EW SERIES UNIT COOLERS ...
Product name: Commercial Dual Discharge Glycol Cool Room Chiller Unit 4.5-12mm Fin space ECG SERIES ...
Product name: Waterproof IP65 Commercial Coolroom Evaporator Air Cooler For Cold Storage EHG SERIES ...
Product name: IP65 Freezer Room Evaporator Glycol Cold Room Cooling System ELG Series ELG SERIES ...