Home Companies KingPo Technology Development Limited

IEC 60601-1- Hand transmitted vibration,Vibration Meter

KingPo Technology Development Limited

Contact Us

[China] country

Trade Verify

Address: RM C, 13/F, HARVARD COMMERCIAL BUILDING, 105-111 THOMSON ROAD, WAN CHAI, HK

Contact name:Lynette Wong

Inquir Now

KingPo Technology Development Limited

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

IEC 60601-1- Hand transmitted vibration,Vibration Meter

Country/Region china
City & Province hong kong hong kong
Categories Measuring & Analysing Instrument Design Services
InquireNow

Product Details

IEC 60601-1- Hand transmitted vibration,Vibration Meter

Technical parameters:
1. According to IEC 60601-1 clause9.6.3
2. Channel: 3.
3. Frequency range: 0.5Hz ~ 400Hz.
4. Measuring range: 60 dB~180 dB.
5. Sensor weight: 300g.
6. Sensor sensitivity: 100mV/g.
7. Frequency: Line, Wd, Wk, Wm, Wh, VLz, Wb, Wc, We, Wj optional.
8. Time: F (0.125s), S (1s), stable (8s).
9. Average score time: 1s to 24h arbitrary setting.
10. Display refresh rate: instantaneous value 0.5s refresh once.
11. Display: 3.5-inch, color screen, 320*480 dot matrix, touch screen.
12. Main configuration: 1 host, 1 whole body vibration acceleration sensor, 1 carrying box, 1 manual

 

 

 

 

 

 


 

 

 

TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING

IEC 60601-1:2005 + Am.1:2012

Medical electrical equipment - Part 1: General requirements for basic safety and essential performance

ClauseMeasurement/testingTesting / measuring equipment / material neededSubcontracting
4.11Power input

Suitable devices for the voltage, current/power and frequency

Supply: 1 phase and 3 phase variacs

 

R
5.3Ambient temperature, humidity, atmospheric pressure

Suitable devices for recording ambient temperature, humidity, atmospheric pressure

 

R
5.7Humidity preconditioning treatment

Environmental conditions: Climate chamber controlling temperature and humidity

 

R
5.9.2Accessible parts

Force gauge (30 N), standard test finger (figure 6), straight unjointed test finger, test hook (figure 7)

 

R
7.1.2Legibility of markings

Illuminance meter

 

R
7.1.3Durability of markings

Distilled water, ethanol (96% pure), isopropyl alcohol , timer / stop watch

 

R
8.4.2Accessible parts including applied parts

Oscilloscope, oscilloscope leads, suitable instruments for measuring voltage, current, capacitance, test pin (Figure 8), metal test rod (D = 4 mm, L = 100 mm), force gauge (10 N)

 

R

8.4.3,

8.4.4

Limitations voltage and energySuitable oscilloscope recorder /set-up & RCL meterR
8.5.5.1Defibrillation protection

5 kV test circuit & oscilloscope interface circuit according to Figures 9 & 10, oscilloscope

 

S
8.5.5.2Energy reduction test

The test circuit according to Figure 11, oscilloscope, oscilloscope leads

 

S
8.6.4Impedance and current-carrying capability

Current source (25 A minimum, 50 or 60 Hz, 6 V maximum)

 

R
8.7Leakage currents and patient auxiliary currents

Measuring device according to Figure 12, mains isolation transformers, variacs, voltmeter, millivoltmeter, aluminium foil, diverse circuits (fig. 13-20)

 

R
8.8.3Dielectric strength

High voltage tester, isolating transformer for HV-tests (fig. 28), stop watch / timer

 

R
8.8.4.1 a)Ball pressure test

Test equipment according to IEC 60695-10-2

 

R
8.8.4.2Resistance to environmental stress

Apparatus for ageing rubber in oxygen

 

S
8.9Creepage distances and air clearances

Oscilloscope, oscilloscope leads, callipers, micrometer, spacing gauges, force gauge (2 N & 30 N), standard test finger (figure 6)

 

R
8.9.1.7Material groups classification

Test equipment according to IEC 60112

 

S
8.9.3.4Thermal cycling

Heating cabinet

 

R
8.11.3.5Cord anchorage

Force gauge (at least 100 N), torque gauge (at least 0.35 Nm)

 

R
8.11.3.6Cord guards

Weights, angle gauge, radius gauge

 

R
9.4Instability hazards

5° & 10° inclined planes or inclinometer or trigonometric calculation, force gauge (at least 220 N), 20 cm by 20 cm test surface, weights, test threshold (10 mm high and 80 mm wide), 7 cm strap, stop watch / timer

 

R
9.5.2Cathode ray tubes

The relevant tests of IEC 60065, Clause 18.

 

S
9.6.2.1Audible acoustic energy

A-weighted sound pressure level according to ISO 3746, ISO 9614-1 or IEC 61672-1

 

S
9.6.3Hand-transmitted vibration

Measurements are made in accordance with ISO 5349-1.

 

S
9.7.5Pressure vessels

Hydraulic pressure test apparatus

 

S
9.8Hazards associated with support systems

Weights or load cell, 0.1 m2 test surface, stop watch / timer, human body test mass (Figure 33)

 

R
10.1X-radiation

Radiation meter

 

S
10.3Microwave radiation

Radiation meter

 

S
10.4LasersTest equipment according to IEC 60825-1S
11.1Excessive temperatures

Temperature indicator/recorder suitable for this function and

thermocouples, 4 wire resistance unit, test corner, variac

 

R
11.2Fire prevention

Spark ignition test apparatus (Figure 34), oxygen gas analyzer

 

S
11.3Constructional requirements for fire enclosuresFV tests specified in IEC 60695-11-10S
11.6.2Overflow

15° inclined plane or inclinometer or trigonometric calculation, stop watch / timer, high voltage tester

 

R
11.6.3Spillage

Flask or graduated cylinder, stop watch / timer

 

R
11.6.5Ingress of water or particulate matter

Classification tests of IEC 60529

 

W
11.6.6Cleaning and disinfection

Dielectric strength and leakage current tests as appropriate

 

R
11.6.7Sterilization

Sterilisation to client specification

 

S
13Hazardous situations and fault conditions

stop watch / timer, voltmeter, ammeter, temperature indicator / recorder suitable for this function and thermocouples, 4 wire resistance unit, cheesecloth

 

R
15.3Mechanical strength

Force gauge (250 N minimum), circular plane surface 30 mm in diameter, 500 g steel ball, 50 mm thick hardwood board (hardwood > 600 kg/m3), 40 mm step, hardwood doorframe (40 mm2), circulating air oven

 

R
15.4.2Temperature and overload control devices

Positive temperature coefficient devices (PTC’s) with IEC 60730-1: 1999, clauses 15, 17, J.15 and J.17

 

S
15.4.3.4Primary Lithium batteries

Performance of the tests identified in IEC 60086-4

 

S
15.4.3.4Secondary Lithium batteriesPerformance of the tests identified in IEC 62133S
15.4.6Actuating parts of controls

Force gauge (at least 100 N), torque gauge (at least 6 Nm), stop watch / timer

 

R
15.4.7Cord-connected hand-held and foot-operated control devices

Force gauge (minimum1 350 N), 30 mm diameter test tool, stop watch / timer

 

R
15.4.7.3Entry of liquids

Classification tests of IEC 60529

 

W
15.5.1.1Transformers

Winding tester for transformers, temperature indicator/recorder suitable for this function and thermocouples variac, loads

 

R
15.5.2Dielectric strength

5x voltage / 5x frequency dielectric strength test fixture, stop watch / timer

 

R
16.6Leakage currents

As in sub-clause 8.7

 

R
A 10.4Light emitting diodes (LEDs)

As specified in IEC 62471

 

S
GProtection against hazards of ignition of flammable anaesthetic mixtures

4 mm & 12 mm diameter test rods, timer / stop watch, gasket test B-b of IEC 60068-2-2, force gauge (minimum 100 N), gas pressure meter (0 to 400 Pa range), voltmeter, ammeter, ohmmeter, meter for capacitance and inductance, oxygen mixture ( volume percentage 12,2 % ± 0,4 %),test apparatus for flammable mixtures (Figure G.7),

 

S
G.4.3Prevention of electrostatic charges

antistatic material testing according to ISO 2882

 

S
LInsulated winding wires for use without interleaved insulationSample is preparation according to IEC 60851-5:1996 & dielectric according to 60601-1; flexibility and adherence test 8 of IEC 60851-3:1996; mandrels of diameters according to Table L.1; heat shock test 9 of IEC 60851-6:1996; 2 mm diameter shot of stainless steel, nickel or nickel plated iron.S
 

 

Hot Products

10mΩ Battery Short Tester, IEC 60335-1-Annex B Standard It is conforms to IEC 60335-1-Annex B ...
IEC 60601-1-Figure 6 Unjointed test finger IEC61032 Figure 2, Diameter: 12mm Length:80mm Insulated ...
IEC 60601-1-figure 7 Test Hook TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING IEC 60601-1...
IEC 60601-1-Test Rod According to IEC 60601-1-clause 8.4.2 Diameter: 4.0(-0.05~+0)mm Length: 100(-0~...
IEC 60601-1-Test Pin According to IEC 60601-1-figure 8 TESTING AND MEASURING EQUIPMENT/ALLOWED ...
IEC 60601-1- Hand transmitted vibration,Vibration Meter Technical parameters: 1. According to IEC ...