Product Details

NCoV Rapid Ag Test Kit Immunochromatography Intended Use

 

Intended Use


This product is used for qualitative detection of nasopharyngeal swabs and oropharyngeal swabs of patients with suspected infection by side-flow immunoassay
 

Sample Requirements


 

[Sample requirements]
It is recommended to use polyester sponge samples with PP (polypropylene) rods for sterile sample collection.
(1) Oropharyngeal specimen collection method: the collection head is slightly tilted, the mouth is open, and both sides of the pharyngeal tonsil are exposed. Swab along the base of the tongue on both sides of the pharyngeal tonsils at least 3 times, then wipe the posterior pharyngeal wall up and down with a cotton swab at least 3 times.
(2) Method of collecting nasopharyngeal specimens: the sampler gently supports the head of the person to be collected with one hand and holds the swab in the other hand. The swab is inserted into the nostril and then slowly penetrated along the bottom of the inferior nasal canal. Arc, do not exert too much force to avoid traumatic bleeding. When the tip of the swab reaches the posterior wall of the nasopharyngeal cavity, gently rotate it once (stay for a while if it is reflexive cough) and slowly remove the swab.
(3) Sample processing: The collected samples should be treated with the sample buffer provided by the kit as soon as possible (if not immediately, the samples should be stored in a dry, sterilized, tightly sealed plastic tube) and stored at 2℃ ~ 8℃ for no more than 24 hours; Long-term storage at -70℃, but should avoid repeated freeze-thaw.

Test Method


Before testing, restore all reagents to room temperature. The test should be carried out at room temperature.
I. Sample extraction (see Figure 1)
1. Add 400μL (about 10 drops) of sample buffer vertically to the sample extraction tube, then insert the sample into the solution in the sample extraction tube and rotate it against the inner wall about 10 times to dissolve the sample in the solution as much as possible.
2. Squeeze the sample q-tip along the inner wall of the extraction tube to keep as much liquid in the tube as possible, then remove and discard the sample.
3. Cover the dropper.

Ii. Test Procedure (See Figure 2)
1. Take the test card out of the sealing bag.
2. Add 2 drops (about 80μL) of the treated sample extract to the sample well of the test card, then start the timer.
3. Read the results after placing the test card at room temperature for 15 minutes. The result was invalid after 20 minutes.

 

Interpretation of test results


Schematic diagram of test card result judgment:
① Invalid results: There is no response line on the quality control line (C line), the test is invalid, and the test should be repeated.
② Negative results: red ribbon, quality control line (line C) is color.
③ Positive results: two red bands, test line (T line) and quality control line (C line) are color.

 

Company profile


 
 

Zhongxiu Qualifications


DOC

 
 
 

Hot Products

2019-NCoV IgM / IgG Detection Kit (Colloidal Gold-Based) Intended Use Intended Use This product is ...
2019-NCoV IgM / IgG Detection Kit (Colloidal Gold-Based) Test Method Intended Use The product was ...
2019-NCoV IgM / IgG Detection Kit (Colloidal Gold-Based) Interpretation Of Test Results Intended Use ...
2019-NCoV IgM / IgG Detection Kit (Colloidal Gold-Based) Company Profile Intended Use It is used to ...
NCoV Rapid Ag Test Kit Immunochromatography Intended Use Intended Use This product is used for ...
NCoV Rapid Ag Test Kit Immunochromatography Sample Requirements Intended Use This product is used ...