Home Companies Henan Lantian Medical Supplies Co.,Ltd.

Clear Smooth PP Virus Sampling Tube PH 7.0-8.5 150mm Swab

Henan Lantian Medical Supplies Co.,Ltd.
Active Member

Contact Us

[China] country

Address: Office Address: Building 4, No. 51 Jingbei 3rd Road, Jingkai Zone, Zhengzhou City. Henan Province,China.

Contact name:chen

Inquir Now

Henan Lantian Medical Supplies Co.,Ltd.

Clear Smooth PP Virus Sampling Tube PH 7.0-8.5 150mm Swab

Country/Region china
City & Province zhengzhou henan
Categories Cotton Pad
InquireNow

Product Details

Disposable Virus Sampling Tube

 

Structure Composition


This product consists of a swab and a tube containing a preservation solution. Non-sterile. The material of the sampling pipe body is PP, the material of the cap is PE, the material of the swab rod is ABS, and the material of the swab head is nylon wool

 

 

Sampling Tube


  • The sampling tube body is transparent, the surface is smooth and clean, and the sticker is clear and complete.
  • The tube body has no stains, no obvious scratches, cracks, uniform thickness of the tube wall, no obvious bending and deformation; The cap matches well with the tube body, and the screw is close, without the phenomenon of crooked cap

 

Preservation Solution


  • Liquid should be odorless, tasteless, no visible particles or impurities, no turbidity, foam or bubbles in the process of transportation and use is a normal phenomenon
  • The standard pH range is between 7.0 and 8.5
  • The storage capacity is:1ml,1.5ml,2ml,2.5ml,3ml,3.5ml,4ml,5ml,6ml,7ml,8ml,9ml,10ml,12ml,15ml,20ml,25ml, Tolerance ±10%

 

Sampling Swab


 

  • The sampling swab should be clean, odorless and tasteless, the sampling hair should be soft, and the surface should be free of yellow spots, impurities and hair loss
  • When the moving rate of the clamp of the breaking force and connection firmness tester is 200mm/min, the pulling force of the sampling swab head and one end of the connecting rod should not be less than 2N
  • When the test span is 6cm (the span should avoid the breaking point), the plastic rod should be able to withstand the axial static pressure of 5N and last for 15s without permanent deformation or breaking
  • The head of the sampling swab should be fixed with 90° vertical downward pressure. The breaking force at the breaking point of the sampling swab should be no less than 2N.
  • When the tube body with preservation solution is matched with the cap, the tube body and the cap do not break, and the preservation solution should have no leakage.
  • Product identification shall be clear, intact, neat and free from damage

 

Swab size                                         Unit: mm

Swab length (L2)Length of broken head (L1)Maximum diameter of swab rod (D1)Minimum diameter of swab rod (D2)Length of swab head (L3)
150±5Mouth swabThroat swabNasal swabMouth swabThroat swabNasal swabMouth swabThroat swabNasal swab20±3
30±580±580±52.5±0.22.5±0.22.5±0.22.0±0.22.0±0.21.1±0.2

 

Intended Use


Suitable for collection, storage and transportation of nasal cavity and oropharynx samples

 

 

Applicable Departments


Fever Outpatient Department, Emergency Department, Laboratory Department, Infectious Control Department

 

 

Usage Method


 

  • Before sampling, clean hands, tear off the outer package of sampling swab, remove the swab, and be careful not to touch the swab head.
  • According to different sampling requirements, use a swab to sample the corresponding parts.
  • Immediately after sampling, place the swab in the collection tube with preservation solution to avoid contact with other parts.
  • Break the swab, discard the tail, tighten the cap and complete the sampling.
  • After sampling, the virus sampling tube will be placed and stored, and transported to the testing department for testing within 1 week.


Matters Needing Attention


 

  • Verify that the outer package of the product is in good condition. Check the storage tube to confirm that there is no leakage.
  • This product is for one-time use, no second use is allowed.
  • The sampling process should be considered as a potential risk of infection, and the operation and handling should comply with the relevant regulations.
  • After use, the product should be disposed of according to the relevant regulations of medical waste.

 

Important


  • Ensure that the top of the sampling swab does not touch any surface prior to sampling.
  • At the risk of choking, caution should be exercised when sampling swabs are inserted into the mouth.
  • After the collection of pathogenic bacteria samples, one-time sampling swabs should be completely inserted into the preservation solution to maximize the retention of pathogenic bacteria.
  • After use, the storage tube and swab should be disposed of in accordance with the relevant medical waste treatment methods

 

Company profile


2019-NCoVAntigen Detection Kit(Immunochromatography) 32019-NCoVAntigen Detection Kit(Immunochromatography) 42019-NCoVAntigen Detection Kit(Immunochromatography) 52019-NCoVAntigen Detection Kit(Immunochromatography) 6
 
Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments.
The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.

Hot Products

Disposable Virus Sampling Tube Structure Composition The product consists of swab and tube ...
Disposable Virus Sampling Tube Structure Composition This product consists of a swab and a tube ...
Disposable Virus Sampling Tube Structure Composition This product consists of a swab and a tube ...
Disposable Virus Sampling Tube Mouth Swab Structure Composition Structure Composition The product ...
N-Terminal Atrial Natriuretic Peptide Precursor Detection Reagent(NT-ProBNP) (Immunofluorescence ...
80~20000pg/ML N-Terminal Atrial Natriuretic Peptide Precursor Detection Reagent(NT-ProBNP) ...