LZCK-55 5m cable IP68 Waterproof Clamp Outdoor Split-core CT 200/5A 0.5s

 

 

LZCK-55 IP68 Outdoor Split-core CTs are designed to meet the growing demand for outdoor installation. The working temperature and humidity is high from -40°C to 55°C. Parameters will be measured and compared without power supply cut-off on account of the split core, so it's popular in the energy management system and power factor correction. It can be used along with many kinds of instruments and devices. and it can be used for power transformer monitoring.

 

GFUVE outdoor split-core ct should be used below 600 volts and 10KV , ant it can customize output with A, mA, V, mV.

If you cannot find information you need or would like assistance, please contact us today. We have designed many more probes than those shown in this catalog, and we manufacture in Beijing, China.

 

 

 

Features

 

Measurement range of 1mA to 1200A AC

Large jaw opening accommodates conductors up to 55mm

Improved ergonomic design and easy operation

High content nickel metal core

Conforms to EN 61010, 600V CAT III

Low phase shift for power measurement

Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters

UL, CE mark

 

ELECTION GUIDE

ModelPrimary rated currentRated loadAperture (mm)Description (mm)Weight (kg)MaterialWater-proof
LZCK-55100-1500A≤10VAφ55180×138×522PCIP68
LMCK185-10300-3000A≤25VAφ185350×283×554.5PCIP68

 

 

Applications

 

Power quality measuring

Large industrial loads

Measuring around cable bundles

Power load monitoring

Waveform analysis

Harmonics measurement

 

 

PARAMETERS

Technical parameters 
StandardsIEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13
Accuracy Class0.5S, 0.5%, 1%, 3%
Range of primary rated current100-1000A
Range of Rated load≤10VA
Rated frequency50/60Hz
Rated secondary current5A or 1A
Rated short-time thermal current40kA, 1S
Rated continuous thermal current150%I1n
Secondary winding power frequency withstand voltage3kV, 1min
Safety Factor Rating(FS) <10
Output signal1A, 5A, 333mV, 1V or 5V(customized)
Cable length2.5m, 5m, 10m(customized)
Flame retardant ABS plastic shell inside, jaw waterproof apron.
Mechanical parameters 
Aperture (mm)Φ55
Dimensions (W×D×H) (mm)180×138×52
Weight (kg)2

 

Photo

 

Hot Products

LZCK2500-10 120mm 50/5a Resin Casting Split core Protection Zero Sequence Current Transformer 5P20 ...
LZCK-55 5m cable IP68 Waterproof Clamp Outdoor Split-core CT 200/5A 0.5s LZCK-55 IP68 Outdoor Split...
100/5A Current Transformer Split core class 1 outdoor for measurement instruments 5A output split ...
LZCK-55 outdoor 300/5a 0.5s current transformer split core clamp type IP67 protective measurement ...
LZCK Series Weatherproof Outdoor Split-core Current Transformer IP68 0.5S Power Distribution line ...
12KV Hydrophobic Cycloaliphatic Epoxy Cast Medium Voltage Outdoor Potential Transformer Applications ...