Home Companies Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Resin Cast IEC61869 Outdoor Current Transformer Split Core For 10KV Power Line

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Active Member

Contact Us

[China] country

Address: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China

Contact name:Andy

Inquir Now

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Resin Cast IEC61869 Outdoor Current Transformer Split Core For 10KV Power Line

Country/Region china
City & Province beijing beijing
InquireNow

Product Details

LMCK185-10 Resin cast IEC61869 Outdoor Current Transformer Split Core, Using in 10KV power line

 

 

Outdoor current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This Type is flame retardance anti-moisture, stable performance, no maintenance.

 

LMCK series outdoor current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case (ABS&PC) which is flame retardance anti-moisture, stable performance, no maintenance.

 

Parameters

 

Technical parameters 
StandardsIEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006
Accuracy Class0.5%, 1%
Range of primary rated current300-5000A
Range of Rated load≤25VA
Technical parameters - continued 
Rated frequency50/60Hz
Rated secondary current5A or 1A
Secondary winding power frequency withstand voltage3kV, 1min
Safety Factor Rating(FS) <5
Flame retardant ABS plastic shell inside, jaw waterproof apron.
Mechanical parameters 
Aperture (mm)Φ185
Dimensions (W×D×H) (mm)350×283×55
Weight (kg)4.5
Working conditions 
Operating temperature-35°C to +55°C, not exceeding +40°C
Environmentoutdoors or indoors
The height of above sea level0- 3000m
ConditionsNo existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed.

 

Compare Datasheet

 

ModelPrimary rated currentRated loadAperture (mm)Description
(mm)
Weight (kg)MaterialWater-proof
LZCK-55100-1500A≤10VAφ55180×138×522PCIP65
LMCK185-10300-5000A≤25VAφ185350×283×554.5PCIP65
LZCK310-10300-600A≤10VAφ50φ50 x φ110 x 321Resinsilicon case (option)
LZCK322-1030-600A≤10VAφ50φ50 x φ110 x 521.6Resinsilicon case (option)
LZCK350-1020-600A≤25VAφ50φ50 x φ110 x 1053.1Resinsilicon case (option)
LZCG530-1030-600A≤20VAφ45φ45 x φ120 x 652.1Resinsilicon case (option)

 

 

 

The Product Picture:

 

Hot Products

150mm diameter 2000A/1A 5P20 Cast Resin Zero Sequence Current Transformer with IEC 61869-2 LZCK2501 ...
LZCG530-10 Protection relay device using 5P20 50/1A Zero Sequence Current Transformer Zero Sequence ...
LZCG530-10 Zero Phase Current Transformer, Ring net cabinet 5P10 Ratio 100A / 1A Zero Sequence ...
LZCK2500-10 120mm 50/5a Resin Casting Split core Protection Zero Sequence Current Transformer 5P20 ...
FU120 IEC60044-1 standard 3000/5A Bus bar type Low Voltage Split core Current Transformer with lead ...
LMCK185-10 Resin cast IEC61869 Outdoor Current Transformer Split Core, Using in 10KV power line ...