Solid Copper Conductor PVC Sheath 1KV 4 Core Armoured Cable​

 

4 Core Armoured Cable​Description

 

Conductor:Class 2

Insulation:XLPE

Sheath: PVC

Cable Speciification: Fire Resistant

Marking: Embossing Or Printing

Sheath Color: Black Or Red

 

4 Core Armoured Cable​ Application:


1)These cables are most suitable for direct burial or for installation on trays or ducts, Where there is
a risk of mechanical damage, armoured cables should be used.
2) For laying in ground along route with large difference of level able to bear external mechanical forces.

 

4 Core Armoured Cable​ Construction

 

Conductor : Plain annealed copper solid or stranded (class 1 or 2) conductor complying with IEC 60228

Insulation : 90°C cross linked XLPE insulation complying with IEC 60502-1

Interlining: PVC type ST2 to IEC 60502, black

Armouring: STA(Steel-Tape Armouring)

Sheath : PVC type ST2 to IEC 60502, black

 

Standards:

International: IEC 60502, IEC 60228, IEC 60332, IEC 60754

China: GB∕T 12706.1-2008, GB∕T 19666-2005

Other standards such as BS,VDE and ICEA upon request

 

Technical data

Rated voltage: 0.6/1kV

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

15 x cable O.D for single-core armoured cables

15 x cable O.D for multi-core non-armoured cables

12 x cable O.D for multi-core armoured cables

 

4 Core Armoured Cable​ Technical Specifications

 

Nom. Cross-section of conductorStrands No./Dia. Of ConductorInsulationThickness of steel tapeSheath ThicknessApprox. O.D.Approx.Max. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
WeightIn air (A)In soil(A)
1×107/1.330.70.21.811.82651.833.57794
1×167/1.670.70.21.812.83381.153.5100120
1×257/2.100.90.21.814.54580.7273.5130155
1×357/2.480.90.21.815.65710.5243.5160185
1×5010/2.561.00.21.816.87120.3873.5195220
1×7014/2.561.10.21.818.79400.2683.5245270
1×9519/2.561.10.21.820.312090.1933.5300320
1×12024/2.561.20.21.822.014650.1533.5349365
1×15030/2.561.40.21.823.817570.1243.5400410
1×18537/2.561.60.21.825.921570.09913.5465465
1×24048/2.581.70.21.828.327320.07543.5550540
1×30060/2.581.80.21.930.933440.06013.5635610
1×40060/2.932.00.2234.442600.0473.5745695
1×50060/3.332.20.52.239.656730.03663.5860780
1×63060/3.762.40.52.344.071330.02833.5990880
2×1.51/1.380.70.21.812.323012.13.52031
2×2.51/1.760.70.21.813.12667.563.52741
2×41/2.230.70.21.814.03164.613.53553
2×61/2.740.70.21.815.03783.083.54566
2×107/1.330.70.21.817.55161.833.56390
2×167/1.670.70.21.819.56721.153.584117
2×257/2.100.90.21.822.99370.7273.5113151
2×357/2.480.90.21.825.211810.5243.5139181
2×5010/2.561.00.21.821.812810.3873.5161210
2×7014/2.561.10.21.924.817340.2683.5204257
2×9519/2.561.10.2227.522780.1933.5252310
2×12024/2.561.20.52.231.330950.1533.5291351
2×15030/2.561.40.52.334.537300.1243.5333393
2×18537/2.561.60.52.538.246180.09913.5385445
2×24048/2.561.70.52.642.258320.07543.5457516
2×30060/2.561.80.52.846.371420.06013.5527583
3×1.51/1.380.70.21.812.725612.13.52031
3×2.51/1.760.70.21.813.53027.563.52741
3×41/2.230.70.21.814.63674.613.53553
3×61/2.740.70.21.815.74493.083.54566
3×107/1.330.70.21.818.46271.833.56390
3×167/1.670.70.21.820.58381.153.584117
3×257/2.100.90.21.824.211910.7273.5113151
3×357/2.480.90.21.826.615280.5243.5139181
3×5010/2.561.00.21.925.518140.3873.5161210
3×7014/2.561.10.2229.024740.2683.5204257
3×9519/2.561.10.52.133.535980.1933.5252310
3×12024/2.561.20.52.336.743860.1533.5291351
3×15030/2.561.40.52.440.753320.1243.5333393
3×18537/2.561.60.52.544.665620.09913.5385445
3×24048/2.561.70.52.850.284140.07543.5457516
3×30060/2.561.80.52.954.9103060.06013.5527583
4×1.51/1.380.70.21.813.529112.13.52031
4×2.51/1.760.70.21.814.43487.563.52741
4×41/2.230.70.21.815.54304.613.53553
4×61/2.740.70.21.816.75343.083.54566
4×107/1.330.70.21.819.87581.833.56390
4×167/1.670.70.21.822.210271.153.584117
4×257/2.100.90.21.826.314790.7273.5113151
4×357/2.480.90.21.829.119140.5243.5139181
4×5010/2.561.00.2228.423340.3873.5161210
4×7014/2.561.10.52.133.635180.2683.5204257
4×9519/2.561.10.52.337.946380.1933.5252310
4×12024/2.561.20.52.441.857010.1533.5291351
4×15030/2.561.40.52.646.069120.1243.5333393
4×18537/2.561.60.52.751.085620.09913.5385445
4×24048/2.561.70.5357.7110520.07543.5457516
4×30060/2.561.80.53.162.7134790.06013.5527583
5×1.51/1.380.70.21.814.332812.13.52031
5×2.51/1.760.70.21.815.33977.563.52741
5×41/2.230.70.21.816.64974.613.53553
5×61/2.740.70.21.818.06233.083.54566
5×107/1.330.70.21.821.48951.833.56390
5×167/1.670.70.21.824.112251.153.584117
5×257/2.100.90.21.828.717800.7273.5113151
5×357/2.480.90.21.931.923290.5243.5139181
5×5019/1.861.00.22.131.928790.3873.5161210
5×7014/2.561.10.52.237.843270.2683.5204257
5×9519/2.561.10.52.442.857400.1933.5252310
5×12024/2.561.20.52.546.870270.1533.5291351
5×15030/2.561.40.52.752.185910.1243.5333393
5×18537/2.561.60.52.957.5106360.09913.5385445
5×24048/2.561.70.53.264.5136510.07543.5457516
5×30060/2.561.80.53.471.0167640.06013.5527583
3×2.5+1×1.51/1.760.70.21.814.13347.563.52741
3×4+1×2.51/2.230.70.21.815.24104.613.53553
3×6+1×41/2.740.70.21.816.45083.083.54566
3×10+1×67/1.330.70.21.819.07011.833.56390
3×16+1×107/1.670.70.21.821.69591.153.584117
3×25+1×167/2.100.90.21.825.313650.7273.5113151
3×35+1×167/2.480.90.21.827.416890.5243.5139181
3×50+1×2510/2.561.00.21.927.921150.3873.5161210
3×70+1×3514/2.561.10.2232.128960.2683.5204257
3×95+1×5019/2.561.10.52.237.442130.1933.5252310
3×120+1×7024/2.561.20.52.341.452510.1533.5291351
3×150+1×7030/2.561.40.52.445.061750.1243.5333393
3×185+1×9537/2.561.60.52.650.077310.09913.5385445
3×240+1×12048/2.561.70.52.856.098570.07543.5457516
3×300+1×15060/2.561.80.5361.3120420.06013.5527583
3×2.5+2×1.51/1.760.70.21.814.93697.563.52741
3×4+2×2.51/2.230.70.21.816.14574.613.53553
3×6+2×41/2.740.70.21.817.45733.083.54566
3×10+2×67/1.330.70.21.820.07851.833.56390
3×16+2×107/1.670.70.21.823.010921.153.584117
3×25+2×167/2.100.90.21.826.815560.7273.5113151
3×35+2×167/2.480.90.21.828.718740.5243.5139181
3×50+2×2510/2.561.00.2229.123840.3873.5161210
3×70+2×3514/2.561.10.52.134.435830.2683.5204257
3×95+2×5019/2.561.10.52.338.546920.1933.5252310
3×120+2×7024/2.561.20.52.442.559090.1533.5291351
3×150+2×7030/2.561.40.52.546.868890.1243.5333393
3×185+2×9537/2.561.60.52.752.587440.09913.5385445
3×240+2×12048/2.561.70.52.958.5110680.07543.5457516
3×300+2×15060/2.561.80.53.164.5135510.06013.5527583
4×2.5+1×1.51/1.760.70.21.815.13837.563.52741
4×4+1×2.51/2.230.70.21.816.44774.613.53553
4×6+1×41/2.740.70.21.817.75983.083.54566
4×10+1×67/1.330.70.21.820.78391.833.56390
4×16+1×107/1.670.70.21.823.511591.153.584117
4×25+1×167/2.100.90.21.827.716670.7273.5113151
4×35+1×167/2.480.90.21.930.421070.5243.5139181
4×50+1×2510/2.561.00.2229.525900.3873.5161210
4×70+1×3514/2.561.10.52.235.039000.2683.5204257
4×95+1×5019/2.561.10.52.339.351440.1933.5252310
4×120+1×7024/2.561.20.52.543.263860.1533.5291351
4×150+1×7030/2.561.40.52.648.376830.1243.5333393
4×185+1×9537/2.561.60.52.853.295660.09913.5385445
4×240+1×12048/2.561.70.5359.7122190.07543.5457516
4×300+1×15060/2.561.80.53.365.6149850.06013.5527583

 

Ordering Advice

Rated Voltage

Application Standard: IEC/BS/UL/GB

Number of Cores

Conductor Size & Construction

Type of Insulation

Armored or unarmored. If armor, the armor type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

 

 

PACKING AND SHIPPING

All cable for exporting are well packed and protected by wooden drum or Wood and Steel Drum.

The packing material is depended on the weight and size of cable.

The good information, manufacture information, and the client's information is firmly printed on each size of drum.

 

After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.

The size of the container is chosen according to weight of total loaded goods or as per the client's requirement.

 

 

 

Hot Products

IEC 60502.1 Copper 1KV XLPE Insulated PVC Sheathed Cable XLPE Insulated PVC Sheathed Cable ...
Chemical Resistance Three Core 1KV IEC XLPE Power Cable​ XLPE Power Cable​ Application: 1) These ...
Fire Resistant Black Sheath 4 Core Copper Armoured Cable Copper Armoured Cable Application For ...
IEC60502-1 Room Laying 0.6/1kV Armoured Power Cable Armoured Power Cable Description The maximum ...
Solid Copper Conductor PVC Sheath 1KV 4 Core Armoured Cable​ 4 Core Armoured Cable​Description ...
XLPE Insulation 1KV Four Core Armoured Power Cable Armoured Power Cable Description XLPE insulated ...