Fire Resistant XLPE Insulated Power Cable Cu Conductor Excellent Electricity

Country/Region china
City & Province jiaxing zhejiang
Categories Power Cables
InquireNow

Product Details

CU / XLPE / STA / PVC Steel Tape Armour Power Cable Cu conductor XLPE Insulation

 

 

Detailed Product Description

Conductor:Class 2

Insulation:XLPE

Sheath: PVC

Cable Speciification: Fire Resistant

Marking: Embossing Or Printing

Sheath Color: Black Or Red

 

Construction

Conductor : Plain annealed copper solid or stranded (class 1 or 2) conductor complying with IEC 60228

Insulation : 90°C cross linked XLPE insulation complying with IEC 60502-1

Interlining: PVC type ST2 to IEC 60502, black

Armouring: STA(Steel-Tape Armouring)

Sheath : PVC type ST2 to IEC 60502, black

 

Standards:

International: IEC 60502, IEC 60228, IEC 60332, IEC 60754

China: GB∕T 12706.1-2008, GB∕T 19666-2005

Other standards such as BS,VDE and ICEA upon request

 

Applications

Laying in room ,tunnel ,cable trench ,and pipes.

 

Technical data

Rated voltage: 0.6/1kV

Maximum Conductor Temperature: under normal (90°C), emergency (130°C) or short circuit no more than 5 s (250°C) conditions.

Min. Ambient Temp. 0°C, after installation and only when cable is in a fixed position

Min. Bending Radius: 20 x cable O.D for single-core non-armoured cables

15 x cable O.D for single-core armoured cables

15 x cable O.D for multi-core non-armoured cables

12 x cable O.D for multi-core armoured cables

 

Certificates

CE, SGS, KEMA and more others at request

 

Technical Specifications

 

Nom. Cross-section of conductorStrands No./Dia. Of ConductorInsulationThickness of steel tapeSheath ThicknessApprox. O.D.Approx.Max. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
WeightIn air (A)In soil(A)
1×107/1.330.70.21.811.82651.833.57794
1×167/1.670.70.21.812.83381.153.5100120
1×257/2.100.90.21.814.54580.7273.5130155
1×357/2.480.90.21.815.65710.5243.5160185
1×5010/2.561.00.21.816.87120.3873.5195220
1×7014/2.561.10.21.818.79400.2683.5245270
1×9519/2.561.10.21.820.312090.1933.5300320
1×12024/2.561.20.21.822.014650.1533.5349365
1×15030/2.561.40.21.823.817570.1243.5400410
1×18537/2.561.60.21.825.921570.09913.5465465
1×24048/2.581.70.21.828.327320.07543.5550540
1×30060/2.581.80.21.930.933440.06013.5635610
1×40060/2.932.00.2234.442600.0473.5745695
1×50060/3.332.20.52.239.656730.03663.5860780
1×63060/3.762.40.52.344.071330.02833.5990880
2×1.51/1.380.70.21.812.323012.13.52031
2×2.51/1.760.70.21.813.12667.563.52741
2×41/2.230.70.21.814.03164.613.53553
2×61/2.740.70.21.815.03783.083.54566
2×107/1.330.70.21.817.55161.833.56390
2×167/1.670.70.21.819.56721.153.584117
2×257/2.100.90.21.822.99370.7273.5113151
2×357/2.480.90.21.825.211810.5243.5139181
2×5010/2.561.00.21.821.812810.3873.5161210
2×7014/2.561.10.21.924.817340.2683.5204257
2×9519/2.561.10.2227.522780.1933.5252310
2×12024/2.561.20.52.231.330950.1533.5291351
2×15030/2.561.40.52.334.537300.1243.5333393
2×18537/2.561.60.52.538.246180.09913.5385445
2×24048/2.561.70.52.642.258320.07543.5457516
2×30060/2.561.80.52.846.371420.06013.5527583
3×1.51/1.380.70.21.812.725612.13.52031
3×2.51/1.760.70.21.813.53027.563.52741
3×41/2.230.70.21.814.63674.613.53553
3×61/2.740.70.21.815.74493.083.54566
3×107/1.330.70.21.818.46271.833.56390
3×167/1.670.70.21.820.58381.153.584117
3×257/2.100.90.21.824.211910.7273.5113151
3×357/2.480.90.21.826.615280.5243.5139181
3×5010/2.561.00.21.925.518140.3873.5161210
3×7014/2.561.10.2229.024740.2683.5204257
3×9519/2.561.10.52.133.535980.1933.5252310
3×12024/2.561.20.52.336.743860.1533.5291351
3×15030/2.561.40.52.440.753320.1243.5333393
3×18537/2.561.60.52.544.665620.09913.5385445
3×24048/2.561.70.52.850.284140.07543.5457516
3×30060/2.561.80.52.954.9103060.06013.5527583
4×1.51/1.380.70.21.813.529112.13.52031
4×2.51/1.760.70.21.814.43487.563.52741
4×41/2.230.70.21.815.54304.613.53553
4×61/2.740.70.21.816.75343.083.54566
4×107/1.330.70.21.819.87581.833.56390
4×167/1.670.70.21.822.210271.153.584117
4×257/2.100.90.21.826.314790.7273.5113151
4×357/2.480.90.21.829.119140.5243.5139181
4×5010/2.561.00.2228.423340.3873.5161210
4×7014/2.561.10.52.133.635180.2683.5204257
4×9519/2.561.10.52.337.946380.1933.5252310
4×12024/2.561.20.52.441.857010.1533.5291351
4×15030/2.561.40.52.646.069120.1243.5333393
4×18537/2.561.60.52.751.085620.09913.5385445
4×24048/2.561.70.5357.7110520.07543.5457516
4×30060/2.561.80.53.162.7134790.06013.5527583
5×1.51/1.380.70.21.814.332812.13.52031
5×2.51/1.760.70.21.815.33977.563.52741
5×41/2.230.70.21.816.64974.613.53553
5×61/2.740.70.21.818.06233.083.54566
5×107/1.330.70.21.821.48951.833.56390
5×167/1.670.70.21.824.112251.153.584117
5×257/2.100.90.21.828.717800.7273.5113151
5×357/2.480.90.21.931.923290.5243.5139181
5×5019/1.861.00.22.131.928790.3873.5161210
5×7014/2.561.10.52.237.843270.2683.5204257
5×9519/2.561.10.52.442.857400.1933.5252310
5×12024/2.561.20.52.546.870270.1533.5291351
5×15030/2.561.40.52.752.185910.1243.5333393
5×18537/2.561.60.52.957.5106360.09913.5385445
5×24048/2.561.70.53.264.5136510.07543.5457516
5×30060/2.561.80.53.471.0167640.06013.5527583
3×2.5+1×1.51/1.760.70.21.814.13347.563.52741
3×4+1×2.51/2.230.70.21.815.24104.613.53553
3×6+1×41/2.740.70.21.816.45083.083.54566
3×10+1×67/1.330.70.21.819.07011.833.56390
3×16+1×107/1.670.70.21.821.69591.153.584117
3×25+1×167/2.100.90.21.825.313650.7273.5113151
3×35+1×167/2.480.90.21.827.416890.5243.5139181
3×50+1×2510/2.561.00.21.927.921150.3873.5161210
3×70+1×3514/2.561.10.2232.128960.2683.5204257
3×95+1×5019/2.561.10.52.237.442130.1933.5252310
3×120+1×7024/2.561.20.52.341.452510.1533.5291351
3×150+1×7030/2.561.40.52.445.061750.1243.5333393
3×185+1×9537/2.561.60.52.650.077310.09913.5385445
3×240+1×12048/2.561.70.52.856.098570.07543.5457516
3×300+1×15060/2.561.80.5361.3120420.06013.5527583
3×2.5+2×1.51/1.760.70.21.814.93697.563.52741
3×4+2×2.51/2.230.70.21.816.14574.613.53553
3×6+2×41/2.740.70.21.817.45733.083.54566
3×10+2×67/1.330.70.21.820.07851.833.56390
3×16+2×107/1.670.70.21.823.010921.153.584117
3×25+2×167/2.100.90.21.826.815560.7273.5113151
3×35+2×167/2.480.90.21.828.718740.5243.5139181
3×50+2×2510/2.561.00.2229.123840.3873.5161210
3×70+2×3514/2.561.10.52.134.435830.2683.5204257
3×95+2×5019/2.561.10.52.338.546920.1933.5252310
3×120+2×7024/2.561.20.52.442.559090.1533.5291351
3×150+2×7030/2.561.40.52.546.868890.1243.5333393
3×185+2×9537/2.561.60.52.752.587440.09913.5385445
3×240+2×12048/2.561.70.52.958.5110680.07543.5457516
3×300+2×15060/2.561.80.53.164.5135510.06013.5527583
4×2.5+1×1.51/1.760.70.21.815.13837.563.52741
4×4+1×2.51/2.230.70.21.816.44774.613.53553
4×6+1×41/2.740.70.21.817.75983.083.54566
4×10+1×67/1.330.70.21.820.78391.833.56390
4×16+1×107/1.670.70.21.823.511591.153.584117
4×25+1×167/2.100.90.21.827.716670.7273.5113151
4×35+1×167/2.480.90.21.930.421070.5243.5139181
4×50+1×2510/2.561.00.2229.525900.3873.5161210
4×70+1×3514/2.561.10.52.235.039000.2683.5204257
4×95+1×5019/2.561.10.52.339.351440.1933.5252310
4×120+1×7024/2.561.20.52.543.263860.1533.5291351
4×150+1×7030/2.561.40.52.648.376830.1243.5333393
4×185+1×9537/2.561.60.52.853.295660.09913.5385445
4×240+1×12048/2.561.70.5359.7122190.07543.5457516
4×300+1×15060/2.561.80.53.365.6149850.06013.5527583

 

Ordering Advice

Rated Voltage

Application Standard: IEC/BS/UL/GB

Number of Cores

Conductor Size & Construction

Type of Insulation

Armored or unarmored. If armor, the armor type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

 

 

PACKING AND SHIPPING

All cable for exporting are well packed and protected by wooden drum or Wood and Steel Drum.

The packing material is depended on the weight and size of cable.

The good information, manufacture information, and the client's information is firmly printed on each size of drum.

 

After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.

The size of the container is chosen according to weight of total loaded goods or as per the client's requirement.

 

Hot Products

Medium Voltage Steel tape Armoured Cable 15KV 3x95 SQMM Stranded Bare Copper Detailed Product ...
CU / XLPE / STA / PVC Steel Tape Armour Power Cable Cu conductor XLPE Insulation Detailed Product ...
8.7/15kV copper conductor XLPE insulation double steel tape armored PVC sheath power cable Detailed ...
6/10KV double steel tape armored power cable with cross section from 35~630mm2 Detailed Product ...
Underground MV power cable with cu/XLPE/CTS/PVC/STA/PVC rated voltage 8.7/15kV Detailed Product ...
XLPE insulation and steel tape armored MV power cable with 6.35/11kV Detailed Product Description ...