Home Companies Zhejiang CHINT Cable Co., Ltd

Single Core PVC Insulated Flexible Wire For Housing Project / Building

Zhejiang CHINT Cable Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 1#Jiangnan Road,Nanhu district ,Jiaxing city, Zhejiang province China

Contact name:May

Inquir Now

Zhejiang CHINT Cable Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Single Core PVC Insulated Flexible Wire For Housing Project / Building

Country/Region china
City & Province jiaxing zhejiang
Categories Electrical Wires
InquireNow

Product Details

Single Core Flexible Copper Pvc Insulation Wire - Class 5 Housing Wire

 

Standards

International: IEC 60227-3:1997

China: GB∕T 5023.3-2008

Other standards such as BS,VDE and ICEA upon request

 

Technical data

Rated voltage: See Table 3.

Max. Operating Temp.: 70 ℃.

Min. Ambient Temp.: 20±10 ℃

 

Description:

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V——Non-sheathed cables for fixed wiring

Fixed laying power supply connection for Electrical equipment.

 

Constructions

Conductor : Compact stranded copper conductor, Cl.5 as per IEC 60228

Insulation : PVC(Polyvinyl chloride) rated at 70 ℃

 

Figure 1 Product structure sketch

 

Note:1- Conductor; 2- Insulation.

Note:

Insulation identification as per standards or customer requirement

 

Applications

Indoor, distribution cabinet, electrical connection.

 

Table 2 - Minimum recommended bending radii at cable temperature of (20±10)℃

Cable typeInstallations minimum bending radius
Cable diameter
mm
Cable diameter
mm
Cable diameter
mm
Cable diameter
mm
Flexible cable (thermoplastic, e.g. PVC)d≤88<d≤1212<d≤20d>20
Fixed installation3 D3 D4 D4 D
Free movement5 D5 D6 D6 D
At inlet of portable appliance or mobile equipment a5 D5 D6 D6 D
Under mechanical load b9 D9 D9 D10 D
Festooned c10 D10 D11 D12 D
Repeated reeling b7 D7 D8 D8 D
Deflected by pulleys b10 D10 D10 D10 D
D = the overall diameter of round cables or the smaller dimension of flat cables.
a No mechanical load on the cable
b See 5.6.2 of IEC 62440 with regard to dynamic stess.
c As in gantry cranes.

 

 

Table 3 - Technical Specifications

Cable typeRated voltageStrands No./Dia. Of ConductorInsulation ThicknessApprox. O.D.Approx.
Weight
Max. D.C Resistance of Conductor (20 ℃)Testing Voltage A.CCurrent Rating
In Air(A) /30℃
/Vpc/mmmm(mm)kg/kmΩ /kmkV/5minsingledoubletriple
60227 IEC 06 (RV) 300/500V 1×0.5300/5001/16/0.200.62.293920001264
60227 IEC 06 (RV) 300/500V 1×0.75300/5001/24/0.200.62.4122620001485
60227 IEC 06 (RV) 300/500V 1×1300/5001/30/0.200.62.61419.520001797
60227 IEC 02 (RV) 450/750V 1×1.5450/7501/30/0.250.73.12013.3250022118
60227 IEC 02 (RV) 450/750V 1×2.5450/7501/49/0.250.83.7317.982500291310
60227 IEC 02 (RV) 450/750V 1×4450/7501/53/0.300.84.3464.952500401711
60227 IEC 02 (RV) 450/750V 1×6450/7507/12/0.300.85.3683.32500512418
60227 IEC 02 (RV) 450/750V 1×10450/7507/11/0.4016.71131.91250074--
60227 IEC 02 (RV) 450/750V 1×16450/7507/17/0.4017.91661.212500100--
60227 IEC 02 (RV) 450/750V 1×25450/7507/26/0.401.29.92540.782500135--
60227 IEC 02 (RV) 450/750V 1×35450/7507/36/0.401.211.23420.5542500165--
60227 IEC 02 (RV) 450/750V 1×50450/75019/19/0.401.413.44880.3862500215--
60227 IEC 02 (RV) 450/750V 1×70450/75019/17/0.501.415.36800.2722500260--
60227 IEC 02 (RV) 450/750V 1×95450/75019/23/0.501.617.68910.2062500300---
60227 IEC 02 (RV) 450/750V 1×120450/75019/30/0.501.619.31,1290.1612500350---
60227 IEC 02 (RV) 450/750V 1×150450/75037/19/0.501.821.51,4020.1292500400---
60227 IEC 02 (RV) 450/750V 1×185450/75037/25/0.49224.11,7400.1062500450---
60227 IEC 02 (RV) 450/750V 1×240450/75037/33/0.492.227.42,2850.08012500550---
 

 

Ordering Advice

Rated Voltage

Application Standard: IEC/BS/UL/GB

Number of Cores

Conductor Size & Construction

Type of Insulation

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

 

PACKING AND SHIPPING

We are capable of meeting the strictest delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.

Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self-adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

 

 

 

Hot Products

6mm2 1000V AC TUV 2pfg1169 Certificated Double Insulated Photovoltaic PV Cable Solar Cable Product ...
Single Core Flexible Copper Pvc Insulation Wire - Class 5 Housing Wire Standards International: IEC ...
Non Sheated Electrical Wire Single Core PVC Insulation 0.5mm - 400mm Standards International: IEC ...
H05v-K / H07v-K Flexible PVC Insulated Copper Wire Non Sheated Single Core Cables Description: ...
House Electrical Wire Pure Copper Conductor PVC Insulated 0.5 sq mm - 400 sq mm Constructions ...
PVC Insulated Flexible colourful wires RV Cable House Electrical Wires 100m/roll Ordering Advice ...