Home Companies Zhejiang CHINT Cable Co., Ltd

Light Weight PVC Insulated Wire Stranded Solid Bare Copper Conductor

Zhejiang CHINT Cable Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 1#Jiangnan Road,Nanhu district ,Jiaxing city, Zhejiang province China

Contact name:May

Inquir Now

Zhejiang CHINT Cable Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Light Weight PVC Insulated Wire Stranded Solid Bare Copper Conductor

Country/Region china
City & Province jiaxing zhejiang
Categories Electrical Wires
InquireNow

Product Details

H07V - U Solid Bare Copper Conductor Electrical Wires and House Wiring Cable

 

Constructions

Conductor : stranded copper conductor, Cl.1/Cl.2 as per IEC 60228

Insulation : PVC(Polyvinyl chloride) rated at 70 ℃

 

Applications

Indoor, distribution cabinet, electrical connection.

 

Standards

International: IEC 60227-3:1997

China: GB∕T 5023.3-2008

Other standards such as BS,VDE and ICEA upon request

 

Technical data

Rated voltage: See Table 3.

Max. Operating Temp.: 70 ℃.

Ambient Temp.: 20±10 ℃

 

Description:

Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V——Non-sheathed cables for fixed wiring

Fixed laying power supply connection for Electrical equipment.

 

Table 2 - Minimum recommended bending radius at cable temperature of (20±10)

Cable typeInstallations minimum bending radius
Cable diameter
mm
Cable diameter
mm
Cable diameter
mm
Cable diameter
mm
Cable for fixedd≤88<d≤1212<d≤20d>20
Normal use4 D5 D6 D6 D
Careful bending at termination2 D3 D4 D4 D
D = the overall diameter of round cables or the smaller dimension of flat cables.
 

Table 3 - Technical Specifications

Cable typeStrands No./Dia. Of Conductor

Insulation

Thickness

Approx.

O.D.

Approx.
Weight
Max. D.C Resistance of Conductor (20 ℃)

Testing

Voltage

A.C

Current Rating

In Air

(A)

In Plastic Conduit(A)In Metal Conduit(A)
/pc/mmmm(mm)kg/kmΩ /kmkV/5min/doubletriplequadrupledoubletriplequadruple
60227 IEC 05(BV) 300/500V 1×0.51/1/0.800.62.19362000-------
60227 IEC 05(BV) 300/500V 1×0.751/1/0.980.62.31124.5200015------
60227 IEC 05(BV) 300/500V 1×11/1/1.130.62.41418.1200018121110141311
60227 IEC 01(BV) 450/750V 1×1.51/1/1.380.72.92012.1250023161513191716
60227 IEC 01(BV) 450/750V 1×2.51/1/1.760.83.5317.41250031242119262422
60227 IEC 01(BV) 450/750V 1×41/1/2.230.83.9464.61250042312825353128
60227 IEC 01(BV) 450/750V 1×61/1/2.740.84.5663.08250054413632474137
60227 IEC 01(BV) 450/750V 1×101/7/1.3316.21101.83250078564944655750
60227 IEC 01(BV) 450/750V 1×161/7/1.6717.21661.152500105726557827365
60227 IEC 01(BV) 450/750V 1×251/7/2.101.28.92600.72725001409585751059585
60227 IEC 01(BV) 450/750V 1×351/7/2.481.210.03510.524250017512010593135115105
60227 IEC 01(BV) 450/750V 1×501/19/1.761.411.84780.3872500225150130115165145130
60227 IEC 01(BV) 450/750V 1×701/19/2.101.413.56670.2682500275185165150205185165
60227 IEC 01(BV) 450/750V 1×951/19/2.481.615.89240.1932500340230205185250225200
60227 IEC 01(BV) 450/750V 1×1201/24/2.561.616.51,1520.1532500365270240215290260230
60227 IEC 01(BV) 450/750V 1×1501/30/2.561.818.31,4200.1242500425305275250330300265
60227 IEC 01(BV) 450/750V 1×1851/37/2.56220.61,7940.09912500490355310280380340300
60227 IEC 01(BV) 450/750V 1×2401/48/2.582.223.22,3460.07542500-------
60227 IEC 01(BV) 450/750V 1×3001/60/2.582.425.72,9230.06012500-------
60227 IEC 01(BV) 450/750V 1×4001/60/2.932.629.13,7820.0472500-------
 

Ordering Advice

Rated Voltage

Application Standard: IEC/BS/UL/GB

Number of Cores

Conductor Size & Construction

Type of Insulation

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

 

PACKING AND SHIPPING

We are capable of meeting the strictest delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.


Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self-adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

 

Product photo

 

Hot Products

H07V - U Solid Bare Copper Conductor Electrical Wires and House Wiring Cable Constructions Conductor ...
Low Voltage Flexible Conductor Electrical Cable Non - Sheathed House wire Description: Polyvinyl ...
PVC Insulated single core Non Sheated Solid Conductor Electrical Wire Ordering Advice Rated Voltage ...
Flexible Copper Conductor with Standard IEC 60227 Electrical Cable Wire Figure 1 Product structure ...
Flexible PVC Insulated Triple Cores Wire Cable RVV 0.5mm-0.75mm Standards International: IEC 60227-5...
PVC Insulated Single Core Wire cable flexible cores BVR 0.5mm-400mm Standards China: JB∕T 8734.2...