Home Companies Willfar Information Technology Co. Ltd.

High Efficiency GPRS Module With Super Capacitor For Energy Storage CTY7

Willfar Information Technology Co. Ltd.
Active Member

Contact Us

[China] country

Address: Wasion Industrial Park, 468 West Tongzipo Road, Yuelu District, Changsha, Hunan Province, PRC

Contact name:Eric Yang

Inquir Now

Willfar Information Technology Co. Ltd.

High Efficiency GPRS Module With Super Capacitor For Energy Storage CTY7

Country/Region china
City & Province changsha hunan
Categories Solar Chargers
InquireNow

Product Details

Internal GPRS Communication Module for Smart Meter CTY7

 

Company Profile
Willfar Information Technology Co., Ltd.
- Established in 2004;
- Listed on the STAR Market of the Shanghai Stock Exchange in December 2019;
- Leading supplier of meter reading (AMI) equipment and operation service;
- The first company to develop "One DCU Reading Multi-meter" solution in China;
- The first company to have large-scale application of technologies and systems like "CPU smart-card Charge and Control", "One DCU Reading Multi-meter", LoRa-based RF Communication and "District Metering Area (DMA)”
 
Introduction

- The General Packet Radio Service (GPRS) is a GSM­based wireless packet switched technology used to provide end­to­end wide area wireless IP connections.

- Internal GPRS communication module CTY7 is a high­speed data processing technology which transfers data to users in “Packet” mode. Although the GPRS is a transitional solution from the GSM network to 3G, yet it has prominent advantages in many aspects such as the transfer rate, wireless resource management and billing.

- Users will have a statically or dynamically allocated IP address in addition to a phone number.

- This feature is ideal for a majority of mobile applications.


 
Technical Parameters
 

ItemParameter
Nominal Voltage16V DC
Idle Current1mA@16V
Communication Current62.5mA@16V
Maximum Current625mA
FrequencyEGSM 900/ DCS 1800 or GSM850/PCS 1900
Sensitivity<-108.5dBm
GPRS Connectivity

GPRS multi-slot class 10

GPRS mobile station class B

SIM Interface1.8V/3V
Electrostatic Discharge IEC61000-4-2

Contact discharge, 8kV, 10 cycles;

Air discharge, 15kV, 10 cycles

Specified Operating Temp. Range-25 °C ~ + 55 °C
Limit Operating Temp. Range-40 °C ~ + 70 °C
Limit Temp. Range for Storage & Transport-40 °C ~ + 85 °C
Relative Humidity≤95%, non-condensing

 

Note: Operation, storage and transport of the meter (GPRS Module) at the extreme of this temperature range (class 3K7) should only last for a maximum period of 6 hours.

 

 
Certificate
 
CE

Work Mechanism

 

The first step in the communication process is to have modules ‘online’ in the network (PDP context). Module can search network automatically when changing the SIM card and using public network. And it switch between the operating modes automatically based on the best network coverage. Module can automatic change of network settings is ensured when the SIM card is replaced.

Module continuously has PDP context in the mobile network. There can be data exchange ‘at any time’. In all wake-up scenario, the module will wait for TCP establishment from the Central System during a configurable time.

GPRS Module will be sever.it will create socket and connect to port, then listen the TCP connection from client. And MDM will be client. If it read data from sever, it will create socket to connect the socket of sever. When sever have listened the TCP connection from client, it will accept the connection. TCP connection are confirmed from both side, they could read and write data until end up by client. After they finish data changed, both of they will close TCP connection.

 

Function

 

1. User Interface

- NET LED

No SIM card or no registered to Internet,NET LED light blinks at the frequency of 64ms ON/800ms OFF;if registered on the network,NET LED light blinks at the frequency of 64ms ON/64ms OFF.

- PWR LED

The PWR LED will always blink when the module power on.

- RXD and TXD LED

During the data transmission RXD and TXD LED light blink.

 

2. Antenna Interface

If meter installation is very intensive in the metal box, it need to be used the long antenna. Screw the long antenna with SMA type on the connector by the hand. And the long antenna has to be put outside the meter box as far as possible from the meter.

 

3. RXD LED with red will be blink when it send data

4. TXD LED with green will be blink when it receive data

5. Antenna pedestal with SMA type

6. Main chip is a dual frequency GSM/GPRS chip

7. Super capacitor for energy storage

8. SIM card pedestal for installing SIM card 

 

Installation Requirement

ParameterRange
Temperature-40°C to +70°C
HumidityUp to 95% RH
Environmental protectionIP 54
 

 

Situation

 

For single phase/three phase meter GPRS Module. Pluggable.

 


 
Dimension

For Single Phase Meter

 

 

For Three Phase Meter

 

Hot Products

Communication Module LoRaWAN RF Communication Module WFCM-910LR Company Profile Willfar Information ...
NB Communication Module for Internet Smart Meter Company Profile Willfar Information Technology Co., ...
Communication Module CDMA Communication Module for Internet Smart Meter Company Profile Willfar ...
External GPRS Communication Module for Smart Meter GPRS Data Collection System Company Profile ...
Internal GPRS Communication Module for Smart Meter CTY7 Company Profile Willfar Information ...
RF Mesh AMI Communication Module for Three Phase Meter DC2-RTF1 Company Profile Willfar Information ...