YINGDE VENTECH AIR CONDITIONING CO.,LTD |
|
VENTECH(Vcare) Rooftop pacakge unit
Cooling,Heat pump, Electrical heating
Parameter | Cooling capacity | Heating capacity | Outdoor body size | Outdoor weight | Indoor body size | Indoor weight | Airflow | ESP | Consumed power (KW) |
Noise ≤dB(A) |
||||
Model | kW | kW | L | W | H | kg | L | W | H | kg | (m3/h) | (Pa) | Cooling | |
VWD-118F | 117.9 | 117.6 | 1800 | 1800 | 2230 | 1900 | 2500 | 1800 | 1800 | 450 | 20100 | 250 | 45.01 | 77 |
450 | 46.75 | 77 | ||||||||||||
VWD-126F | 125.9 | 128 | 1800 | 1800 | 2230 | 1900 | 2500 | 2000 | 1800 | 500 | 22800 | 250 | 51.04 | 7S |
450 | 52.82 | 78 | ||||||||||||
VWD-134F | 134.1 | 138.5 | 1800 | 1800 | 2230 | 1900 | 2500 | 2200 | 1800 | 650 | 25400 | 300 | 55.63 | 79 |
500 | 57.88 | 79 | ||||||||||||
VWD-144F | 143.9 | 149.1 | 1800 | 1800 | 2230 | 1900 | 2500 | 2400 | 1800 | 700 | 28100 | 300 | 59.67 | 79 |
500 | 61.94 | 80 | ||||||||||||
VWD-177F | 176.8 | 176.9 | 3000 | 1700 | 2230 | 2300 | 2500 | 2100 | 2200 | 1000 | 29900 | 350 | 69.07 | 80 |
550 | 71.94 | 80 | ||||||||||||
VWD-185F | 184.9 | 186.9 | 3000 | 1700 | 2230 | 2300 | 2500 | 2200 | 2200 | 1100 | 31600 | 350 | 74.82 | 80 |
550 | 77.75 | 81 | ||||||||||||
VWD-193F | 199 | 197.3 | 3000 | 1700 | 2230 | 2300 | 2500 | 2400 | 2300 | 1200 | 37700 | 350 | 82.51 | 81 |
550 | 85.66 | 81 | ||||||||||||
VWD-201F | 201.2 | 207.8 | 3000 | 1700 | 2230 | 2300 | 2500 | 2600 | 2300 | 1360 | 41300 | 350 | 85.66 | 82 |
550 | 89.33 | 82 | ||||||||||||
VWD-216F | 215.9 | 223.7 | 3000 | 1900 | 2230 | 2500 | 2600 | 2400 | 2500 | 1750 | 42100 | 350 | 89.81 | 83 |
550 | 93.49 | 83 | ||||||||||||
VWD-268F | 268.3 | 277 | 3050 | 2100 | 2340 | 3000 | 2600 | 2700 | 2600 | 1960 | 48600 | 450 | 118.14 | 84 |
650 | 122.07 | 85 | ||||||||||||
VWD-288F | 287.9 | 298.2 | 3550 | 2100 | 2340 | 3400 | 2600 | 2900 | 2500 | 2150 | 51400 | 500 | 124.52 | 85 |
700 | 129.37 | 85 | ||||||||||||
VWD-350F | 350 | 359.4 | 3550 | 2100 | 2340 | 3700 | 2600 | 2900 | 2800 | 2300 | 57400 | 500 | 150.58 | 86 |
700 | 155.5 | 86 | ||||||||||||
VWD-402F | 402.4 | 415.5 | 6000 | 1700 | 2230 | 4200 | 2600 | 3200 | 2800 | 2460 | 64000 | 500 | 168.57 | M |
700 | 174.93 | 87 | ||||||||||||
VWD-432F | 431.8 | 447.4 | 6000 | 1900 | 2230 | 5400 | 2600 | 3400 | 2800 | 2560 | 68400 | 550 | 180.09 | B7 |
850 | 184.84 | 8S | ||||||||||||
VWD-528F | 527.8 | 544.6 | 6000 | 2300 | 2230 | 6000 | 2600 | 4000 | 2900 | 2750 | 79300 | 550 | 214.36 | 88 |
850 | 222.37 | 89 | ||||||||||||
VWD-576F | 575,7 | 596.4 | 7100 | 2100 | 2340 | 6500 | 3300 | 4400 | 2900 | 3200 | 88600 | 600 | 245.3 | 89 |
900 | 253.92 | 89 |
Of the central AC systems covered in our survey, we predict that 36 percent will break or experience problems by the end of the eighth year of ownership. Find out the details from our reliability survey, and learn about the types of central air conditioning systems available and how to choose and maintain them. Plus, learn how to find a good contractor to do the work.
❤ Want to learn more about Vcare Wholehouse air conditioner,please contact us by email directly.
Email:karen@chinaventech.com