Horizontal Concealed FCU specification table | Vertical coil three pipes system | ||||||||||||
Model FP WA*-3* | 200 | 300 | 400 | 500 | 600 | 700 | 800 | 1000 | 1200 | 1400 | |||
Air volume | H | m3/h | 340 | 510 | 680 | 850 | 1020 | 1200 | 1360 | 1700 | 2040 | 2380 | |
M | 280 | 380 | 515 | 660 | 705 | 910 | 1040 | 1280 | 1560 | 1800 | |||
L | 1B0 | 260 | 340 | 430 | 530 | 610 | 710 | 860 | 1060 | 1190 | |||
Cooling capacity | H | W | 2020 | 3010 | 3700 | 4560 | 5600 | 6400 | 7600 | 9000 | 10800 | 12600 | |
M | 1683 | 2742 | 3000 | 3716 | 4424 | 5630 | 6435 | 7470 | 9296 | 10623 | |||
L | 1561 | 2293 | 2479 | 2921 | 3793 | 4905 | 5606 | 7200 | 8543 | 8820 | |||
Heating capacity | H | W | 3500 | 5300 | 6700 | 8200 | 10100 | 10940 | 13500 | 15000 | 18900 | 20000 | |
M | 2526 | 3533 | 5153 | 5954 | 7099 | 8057 | 9906 | 11560 | 15163 | 18600 | |||
L | 1682 | 2321 | 3449 | 4258 | 4833 | S558 | 6774 | 7500 | 10085 | 14240 | |||
Motor | Input power(H) | Normal ESP (12Pa) | W | 37 | 52 | 62 | 76 | 96 | 113 | 134 | 152 | 189 | 228 |
High ESP (30Pa) | 44 | 69 | 72 | 87 | 108 | 134 | 156 | 174 | 212 | 253 | |||
Super High ESP (50Pa) |
49 | 66 | 84 | 100 | 118 | 158 | 174 | 210 | 250 | 300 | |||
Heat exchanger (3-pipe) | Cooling/ Heating |
Water flow | m3/h | 0.367 | 0.517 | 0.638 | 0 796 | 0.978 | 1.128 | 1.371 | 1.516 | 1 822 | 2.152 |
Water drop pressure | kPa | 17 | 22 | 18 | 20 | 30 | 20 | 30 | 30 | 30 | 40 | ||
Noise | H | Normal ESP (12Pa) | dB(A) | ≤37 | ≤39 | ≤41 | ≤43 | ≤45 | ≤47 | ≤46 | ≤48 | ≤50 | ≤52 |
High ESP (30Pa) | ≤40 | ≤42 | ≤44 | ≤46 | ≤47 | ≤49 | ≤48 | ≤50 | ≤52 | ≤54 | |||
Super High ESP (50Pa) |
≤42 | ≤44 | ≤46 | ≤47 | ≤49 | ≤51 | ≤50 | ≤52 | ≤54 | ≤56 | |||
Dimension | Length | mm | 655 | 785 | 885 | 945 | 1065 | 1185 | 1405 | 1525 | 1725 | 1925 | |
Width | 496 | 466 | 466 | 466 | 466 | 466 | 466 | 466 | 466 | 466 | |||
Height | 243 | 243 | 243 | 243 | 243 | 243 | 243 | 243 | 243 | 243 | |||
Unit weight | No return air box | KG | 12 | 14 | 16 | 17 | 18 | 19 | 26 | 29 | 32 | 35 |
*Cold water cooling condition: return air :DB 27℃/WB 19.5℃; fresh air DB35℃/WB28℃;cold water inlet/outlet 7℃/12℃.
*Heat water cooling condition: return air :DB 15℃/fresh air DB 7℃;inlet/outlet water: 60℃/50℃.
*Heating retur air condition: DB 15℃,fresh air:DB 7 ℃/vapor inlet:115℃,pressure:0.2Mpa.
Efficiency
This describes how much cooling the unit delivers for each watt of electricity. Efficiency is expressed as the seasonal energy-efficiency rating, or SEER. The minimum SEER for a split system central air conditioner allowed today is 14, so look for units with SEER ratings of 15 or greater. The higher the SEER, the more you can lower your energy costs.