XBD electric fire pump unit and XBC diesel engine emergency pump unit comply with national standards GB6245-1998 "Fire Pump Performance Requirements and Test Methods" and GB/T1147-1987 "General Technical Conditions for Internal Combustion Engines". They can be equipped with NPS, KB, IS, ISG, DL, D, DG, LB and other pump types respectively. Various supporting forms such as horizontal split type, horizontal single-stage cantilever type, pipeline type, vertical multi-stage, horizontal multi-stage, vertical long axis and so on are formed to suit various places and conditions (different power, speed different water sources, etc.). XBD and XBC type units are mainly suitable for fire protection projects such as industrial and mining enterprises, hotels, high-rise buildings, gas stations, oil depots, ports, etc. Safety protection, cooling, emergency water supply, and other water supply projects that require high reliability and automated control. It mainly transports clean water without solids or liquids with a viscosity similar to that of clean water. If the medium transported by the user contains acid or alkali, it should be specifically mentioned when ordering. The temperature of the transported medium is 0°C ~ +80°C. If appropriate cooling measures are taken, higher temperature media can be transported.
Model Description:
Example: XBD5/100-250S
XB means fire pump
XBD means electric fire pump unit, XBC means diesel emergency pump unit.
5 means the rated lift of the pump is 50m or the rated pressure is 0.5Mpa.
100 means the rated flow rate of the pump is 100l/s.
250 represents the inlet diameter of the pump.
S represents the horizontal split type (I, G, D, L, and C represent horizontal single-stage cantilever type, pipeline type, horizontal multi-stage type, vertical multi-stage type, and vertical long axis respectively).
Characteristics and selection instructions of the pump unit:
XBD electric fire pump sets are powered by motors from major domestic manufacturers. At the same time, they can be equipped with low-voltage, high-voltage and explosion-proof motors of different protection levels according to the user's use environment and conditions. Its characteristics are simple operation and maintenance, low noise, and low equipment requirements. few. Automatic control cabinets can be provided in complete sets to achieve automatic control and remote control purposes.
The XBC series is our company's diesel emergency (fire) pump unit, equipped with a fully automatic control cabinet.
XBC diesel engine pump set is powered by various series of 10-1000kW diesel engines produced by Volvo, Cummins, Deutz and domestic diesel engine manufacturers. It is assembled with a high-elastic coupling, reducer, etc. and a water pump. It has the characteristics of quick start, reliability, strong emergency response, compact structure, and easy maintenance. In order to adapt to the characteristics of the use site, ensure its reliability, and adapt to its emergency characteristics, we recommend that users give priority to imported diesel engines such as Volvo, Deutz, and Cummins, which have beautiful appearance, good starting performance, reliable continuous operation, low noise, and are easy to maintain. Easy maintenance, etc.
The XBC series diesel engine emergency (fire) pump unit is a highly mechanical and electrically integrated automatic emergency system. It has manual emergency start function (when the automatic control and components fail, you can go to the machine to manually start the emergency start), automatic control function (you only need to set the oil temperature, oil pressure, speed, water temperature, water pressure, voltage, etc. in advance , the lower limit warning value, the system will enter the automatic control and warning state), quick start function (the time from start to rated load is about 7S), remote monitoring function (through the remote monitoring interface of the automatic control cabinet, the signal can be transmitted to the Control room, remote monitoring is carried out under instructions from the central control room), self-alarm function (the unit is equipped with various monitoring sensors, which monitor and issue audible and visual alarms when an abnormality occurs in the system), automatic charging function (the battery pack is charged by the mains during shutdown) Float charging, the diesel engine generator self-replenishes the battery pack after starting up), complete display function (all alarm indications, etc. can be displayed through indicator lights and digital meters for intuitive viewing).
The new generation XBC series diesel engine emergency (fire) pump unit intelligent control system not only has all the above functions, but also builds a self-built unit system within the emergency diesel engine automatic control part. The system will be connected to external events and combined with voice navigation and animation technology to realize automatic prompting and recording of unit hardware faults, and prompt users with specific fault points and details through a combination of images (8/10-inch TFT LCD display), text and voice. Instruct users how to troubleshoot. Through reasonable settings of the system, it can also be used to automatically prompt users to perform timely and effective unit maintenance to ensure that it is always in a good standby state.
The new generation of intelligent control system can also be equipped with GPRS wireless communication interface. For example, connecting the GPRS wireless communication interface with the internal electronic secretary code segment can meet the remote wireless timely query, reporting and operation requirements, and realize the remote monitoring of the unit through the wireless network. (The operation and abnormal status of the unit can be immediately reported to relevant personnel, which is especially suitable for occasions with high timeliness requirements). This function needs to be specifically mentioned when ordering.
XBC series emergency (firefighting) diesel engine pump unit There are two ways to connect the diesel engine and the pump unit: directly connected through a rubber elastic coupling, and the other is connected through a gearbox.
Cooling method: water cooling and air cooling. In order to ensure that the unit can work normally in cold climates below 5℃, the unit can be equipped with a preheating function according to user needs. When ordering, please specify the above characteristics.
XBD electric fire pump unit performance parameter table
Unit Type | flow | Lift | Rotating speed | Pump efficiency | Shaft power | Matching motor | Diameter of impeller | Pump diameter | weight | Matching pump model | ||
Q | H | n | η | Pa | import | exit | ||||||
m3/h | l/s | m | r/min | % | kw | mm | mm | mm | Kg | |||
XBD5/14-I | 50.4 | 14 | 50 | 2900 | 69 | 9.9 | Y160M2-2/15KW | 197 | 80 | 50 | 225 | KB80-50-200 |
XBD5/14-G | 50.4 | 14 | 50 | 2900 | 67 | 10.2 | Y160M2-2B5/15KW | 197 | 80 | 80 | 177 | ISG80-200 |
XBD5/14-L | 50.4 | 14 | 60 | 1450 | 70 | 11.8 | Y160L-4B5/15KW | 255 | 80 | 65 | 784 | 80DL-20×3 |
XBD8/14-I | 50.4 | 14 | 80 | 2900 | 63 | 17.4 | Y180M-2/22KW | 243 | 80 | 50 | 346 | KB80-50-250 |
XBD8/14-G | 50.4 | 14 | 80 | 2900 | 59 | 18.6 | Y180M-2B5/22KW | 243 | 80 | 80 | 245 | ISG80-250 |
XBD8/14-L | 50.4 | 14 | 80 | 1450 | 70 | 15.7 | Y180L-4B5/22KW | 255 | 80 | 65 | 951 | 80DL-20×4 |
XBD12.5/14-80I | 50.4 | 14 | 125 | 2950 | 54 | 31.8 | Y200L2-2/37KW | 307 | 80 | 50 | 369 | KB80-50-315 |
XBD12.5/14-G | 50.4 | 14 | 125 | 2950 | 54 | 31.8 | Y200L2-2B5/37KW | 307 | 80 | 80 | 360 | ISG80-315 |
XBD12.5/14-L | 50.4 | 14 | 120 | 1450 | 70 | 23.5 | Y200L-4B5/30KW | 255 | 80 | 65 | 1205 | 80DL-20×6 |
XBD3.2/28-I | 100.8 | 28 | 32 | 2900 | 78 | 11.3 | Y160M2-2/15KW | 165 | 100 | 80 | 265 | KB100-80-160 |
XBD3.2/28-G | 100.8 | 28 | 32 | 2900 | 76 | 11.6 | Y160M2-2B5/15KW | 165 | 100 | 100 | 195 | ISG100-160 |
XBD3.2/28-L | 100.8 | 28 | 40 | 1450 | 72 | 15.3 | Y180M-4B5/18.5KW | 267 | 100 | 80 | 944 | 100DL-20×2 |
XBD5/28-G | 100.8 | 28 | 50 | 2900 | 74 | 18.5 | Y180M-2B5/22KW | 198 | 100 | 100 | 216 | ISG100-200 |
XBD5/28-L | 100.8 | 28 | 60 | 1450 | 72 | 22.9 | Y200L-4B5/30KW | 267 | 100 | 80 | 1160 | 100DL-20×3 |
XBD5/28-I | 100.8 | 28 | 50 | 1450 | 65 | 21.1 | Y200L-4/30KW | 387 | 125 | 100 | 516 | KB125-100-400 |
XBD8/28-I | 100.8 | 28 | 80 | 2950 | 72 | 30.5 | Y200L2-2/37KW | 248 | 100 | 65 | 355 | KB100-65-250 |
XBD8/28-G | 100.8 | 28 | 80 | 2950 | 69 | 31.8 | Y200L2-2B5/37KW | 248 | 100 | 100 | 332 | ISG100-250 |
XBD8/28-L | 100.8 | 28 | 80 | 1450 | 72 | 30.5 | Y225S-4B5/37KW | 267 | 100 | 80 | 1300 | 100DL-20×4 |
XBD8.6/28-D | 100.8 | 28 | 86 | 2950 | 77.5 | 30.5 | Y200L2-2/37KW | 156 | 125 | 125 | 715 | 125D25×4 |
XBD12.5/28-I | 100.8 | 28 | 125 | 2950 | 66 | 52.0 | Y280S-2/75KW | 307 | 100 | 65 | 819 | KB100-65-315 |
XBD12.5/28-G | 100.8 | 28 | 125 | 2950 | 66 | 52.0 | Y280S-2B5/75KW | 307 | 100 | 100 | 552 | ISG100-315 |
XBD12/28-L | 100.8 | 28 | 120 | 1450 | 72 | 45.8 | Y250M-4B5/55KW | 267 | 100 | 80 | 1661 | 100DL-20×6 |
XBD12.9/28-D | 100.8 | 28 | 129 | 2950 | 77.5 | 45.7 | Y250M-2/55KW | 156 | 125 | 125 | 745 | 125D25×6 |
XBD5.2/45-S | 162 | 45 | 52 | 2950 | 81 | 28.3 | Y200L2-2/37KW | 206 | 150 | 100 | 529 | NPS150-210 |
XBD5/45-I | 162 | 45 | 50 | 2950 | 81 | 27.2 | Y200L2-2/37KW | 210 | 125 | 100 | 451 | KB125-100-200 |
XBD5/45-G | 162 | 45 | 50 | 2950 | 77 | 28.6 | Y200L2-2B5/37KW | 210 | 125 | 125 | 385 | ISG125-200 |
XBD5/45-L | 162 | 45 | 50 | 1450 | 76 | 29.0 | Y225S-4B5/37KW | 301 | 150 | 125 | 1130 | 150DL-25×2 |
XBD7.9/45-S | 162 | 45 | 79 | 2950 | 77 | 45.3 | Y250M-2/55KW | 245 | 150 | 100 | 719 | NPS150-240 |