Yuyao No. 4 Instrument Factory |
Verified Suppliers
|
|
ZW series 2-way semi direct acting ( NO ) solenoid valve
Water solenoid valve Features:
Simple structure, small size, good sealing performance, easy
maintenance.
working medium:water,liquid,air,light oil(viscosity≤20cst)
medium temperature:-5 ~ 80℃
working pressure:0 ~ 6 bar
working type:semi direct acting(NO)
valvebody material:forged brass SS304
sealing material:NBR
interface:G thread NPT thread
working voltage:AC220~240V AC110V 50/60Hz DC24/12V IP65 H degree
DN10~20 AC 28VA DC 18W DN25~50 AC 45VA DC 31W
options:EPDM(-10~130℃)
VITON(-10~120℃)
Rc thread Es low power energy saving coil lead wire iron coil
ZW-series(NO)solenoid valve specification table
model | orifice size ( mm ) | interface size | Cv | working pressure (bar | length×width×height ( mm ) | Weight (Kg) | ||
AC220V | DC24V | brass | SS304 | |||||
ZW-10NK | 15 | 3/8" | 3.5 | 0~6 | 0~6 | 60×45×109 | 0.75 | 0.7 |
ZW-15NK | 15 | 1/2" | 3.5 | 0~6 | 0~6 | 60×45×109 | 0.75 | 0.7 |
ZW-20NK | 20 | 3/4" | 7.6 | 0~6 | 0~6 | 67×50×119 | 0.8 | 0.75 |
ZW-25NK | 25 | 1" | 12 | 0~6 | 0~6 | 82×66×127 | 1.3 | 1.1 |
ZW-32NK | 32 | 11/4" | 24 | 0~6 | 0~6 | 102×82×162 | 2.2 | 2.0 |
ZW-40NK | 40 | 11/2" | 29 | 0~6 | 0~6 | 110×85×168 | 2.5 | 2.3 |
ZW-50NK | 50 | 2" | 48 | 0~6 | 0~6 | 134×108×182 | 3.3 | 3.1 |
Water solenoid valve use and maintenance:
1, it is recommended to use the unit to send the person responsible
for maintenance.
2, the solenoid valve is installed into the media need to pass
several experimental action shall be put into use after confirming
normal.
3, large internal and external valve should be cleaned regularly
and the title of the pull side of the dirt, careful not to damage
the sealing surface.
4, when the solenoid valve is a long time to do, should be closed
before the valve manual valve, when re-enabled, steam solenoid
valve should condensate removal and clean, and make trial action
several times, only to be put into use after the switch to normal.
5, when the solenoid valve from the pipeline do not remove, the
internal parts should be scrubbed and blowing with compressed air
storage.
6, when used for a long time, such as a seal between the piston and
the valve seat is bad, the piston sealing surface re-polished, and
now seat grinding.
7, in operation, should pay attention to before and after the valve
pressure gauge required working pressure must not exceed the rated
pressure, working pressure must be within the rated pressure range.
When the operating pressure exceeds the rated pressure or working
pressure exceeds the rated pressure, the solenoid valve to stop
using closed before and after manual valves, solenoid valves to
prevent explosions and leaks.