Home Companies Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

JLSW-200D 60dB R22 Water Cooled Screw Chiller For Large Commercial Buildings Easy To Maintain

Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: Add: No.19,Second Street,Huangling Road,Lubian Village,Chashan Town,Dongguan,Guangdong,China.

Contact name:Jlschiller

Inquir Now

Dongguan Jialisheng Refrigeration Equipment Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

JLSW-200D 60dB R22 Water Cooled Screw Chiller For Large Commercial Buildings Easy To Maintain

Country/Region china
City & Province dongguan guangdong
Categories Home Product Making Machinery Parts
InquireNow

Product Details

JLSW-200D Efficient And Easy-To-Maintain Water-Cooled Screw Chiller For Large Commercial Buildings
 

Product Description:


Water-cooled screw chiller is a type of refrigeration equipment that uses water cooling and uses a screw compressor as the main refrigeration method. It is mainly composed of screw compressor, condenser, evaporator and control system.
The screw compressor is the core component of the water-cooled screw chiller. It compresses the refrigerant through a rotating screw, increasing the temperature and pressure of the refrigerant. Screw compressors have efficient and stable refrigeration performance and are suitable for large-scale refrigeration systems.


 

 

Production Features:


A water-cooled screw twin-head chiller is a chiller configuration that has two independent screw compressor heads to provide refrigeration capacity. The following are some descriptions of water-cooled screw double-head chillers:
1. Double-head configuration: The water-cooled screw double-head chiller has two independent screw compressor heads. Each machine head includes a main screw and a slave screw, which can operate independently or simultaneously to provide refrigeration capacity according to actual needs.

 

2. Independent control: Each machine head has an independent control system and can be adjusted and controlled independently. This means that under different workload conditions, you can choose to use one machine head or two machine heads at the same time according to your needs to achieve better energy efficiency and precise cooling control.
 

3. Load balancing: Double head chillers are designed to achieve load balancing. When load demand is low, only one machine head can be used to reduce energy consumption. When load demand increases, both heads can be started simultaneously to meet higher cooling needs.
 

4. Reliability and backup: The dual-head configuration provides system redundancy and backup functions. If one machine head needs repair or fails, the other machine head can continue to operate to ensure system reliability and continuous cooling capacity.
 

5. Capacity adjustment: The double-head chiller also has a capacity adjustment function, which can be adjusted according to actual needs. By controlling the number and operating status of the machine heads, the refrigeration capacity can be flexibly adjusted to adapt to different process requirements or changing load demands.
 

Water-cooled screw double-head chillers are suitable for applications requiring higher cooling capacity and more flexible control. They are commonly used in large industrial productions, commercial centers, medical facilities and other places where stable, reliable refrigeration systems are required. This configuration provides increased cooling capacity and system redundancy to ensure continuous, efficient cooling operation.

 

 

Working Principle:


The working principle of the water-cooled screw chiller mainly includes four processes of compression, condensation, expansion and evaporation.
1.Compression process: Under the action of the screw compressor, the refrigerant is compressed into a high-temperature and high-pressure gas, while absorbing the surrounding heat.


2.Condensation process: High-temperature and high-pressure refrigerant enters the condenser, and through contact with cold water or surrounding air, it emits heat and cools into a high-pressure liquid.


3.Expansion process: The high-pressure liquid refrigerant enters the evaporator through the throttle valve, the pressure drops suddenly, and the liquid refrigerant expands into a low-pressure refrigerant while absorbing the surrounding heat.


4.Evaporation process: The low-pressure refrigerant enters the evaporator, absorbs surrounding heat through contact with water or air, turns into a low-temperature and low-pressure refrigerant, and returns to the compression process.


Through such a cycle process, the water-cooled screw chiller can deliver cold water to the area that needs to be cooled to achieve the effects of cooling, dehumidification and keeping the air fresh. At the same time, the water-cooled screw chiller will also emit a certain amount of heat, which needs to be dissipated through cooling towers or other heat dissipation equipment to ensure the normal operation of the system.

 

 

Techinical Parameters:

 

ModelJLSW-30DJLSW-40DJLSW-50DJLSW-60DJLSW-80DJLSW-100DJLSW-120DJLSW-150D
Cooling capacityKW/h100140180200260370430550
TR28.539.851.256.973.9105.2122.3156.4
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415 50HZ/60HZ
CompressorType Semi-hermetic screw
PowerKW22303641568093118
electric currentA3951657195135156198
RefrigerantType R22/R407c
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
filling volumeKg16.522.227.533.444.455.666.582.6
Evaporator  shell and tube
Flowm³/h17.222.429.33343.964.275.295.3
DiameterinchG2.5"G3"G3"G3"G3"G4"G4"G4"
CompressorType shell and tube
Flowm³/h22.429.235.242.957.884.3101.1123.9
DiameterinchG2.5"G3"G3"G3"G3"G4"G4"G4"
Protective deviceHigh and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine sizeLmm22002250235024502500290030003000
Wmm80080080090090090015001500
Hmm15001600165017501800185015001550
Unit weightKg960990126013801520183021502580

 

 

ModelJLSW-170DJLSW-200DJLSW-230DJLSW-260DJLSW-280DJLSW-310DJLSW-350DJLSW-400D
Cooling capacityKW/h6207108309301020113012701530
TR176.3201.9236264.4290321.3361.1435
Temperature range 5℃~35℃(Below 0℃ can be customized)
Power supply 3N-380V/415 50HZ/60HZ
CompressorType Semi-hermetic screw
PowerKW130150175200225250281325
electric currentA218253295335390432480553
RefrigerantType R22/R407c
Control method Temperature Sensing External Pressure Equalizing Expansion Valve
filling volumeKg93.8111.2126.8144.1155.4170.9193.2220.9
Evaporator  shell and tube
Flowm³/h108.6126.3144.9163.8176.4196.5222.4252.6
DiameterinchG5"G5"G6"G6"G8"G8"G8"G8"
CompressorType shell and tube
Flowm³/h141.1166.2190.9215.8232.4258.6290.8333.2
DiameterinchG5"G5"G6"G6"G8"G8"G8"G8"
Protective deviceHigh and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine sizeLmm36003600360036503650370037004200
Wmm15001500150016001650175017501750
Hmm16501650170017001700175018001800
Unit weightKg30503200345037804060433046004820

 

 

 


Application Industry:


Water-cooled screw twin-head chillers are suitable for many different applications. Here are some common application scenarios:
1. Large commercial buildings: Double-head chillers are often used in large commercial buildings, such as shopping malls, office buildings, hotels, and exhibition centers. These buildings often require high refrigeration capacity to meet the large cooling demands, such as central air conditioning systems, cooling towers and other refrigeration equipment.

 

2. Industrial production: Many applications in the industrial field require a large amount of cooling capacity, such as manufacturing, chemical plants, electronics factories, and pharmaceutical factories, etc. The double-head chiller can provide efficient refrigeration capacity to meet the cooling needs in these industrial production processes.

 

3. Medical facilities: Hospitals, laboratories and medical facilities often require precise temperature control and stable refrigeration systems. The dual-head chiller can provide reliable cooling capacity to ensure the normal operation of medical equipment and provide a comfortable environment for patients and medical staff.

 

4. Data Center: Data centers require powerful cooling capabilities to maintain normal operating temperatures of servers and network equipment. The dual-head chiller can meet the data center's need for efficient cooling and ensure equipment reliability and performance.

 

5. Refrigeration process: The double-head chiller can also be used in various refrigeration processes, such as food processing, beverage production and refrigeration storage. In these applications, precise temperature control and high refrigeration capacity are key to ensuring product quality and safety.

 

Overall, water-cooled screw twin-head chillers are suitable for applications that require large amounts of cooling capacity, flexible control, and reliability. They play an important role in large commercial buildings, industrial production, medical facilities, data centers and refrigeration processes. The specific application needs and size will determine the capacity and configuration of the dual-head chiller selected.

 

      
  Automotive Manufacturing           Chemical Engineering                  Electronics Industry                Electroplating Industry

 

     

  Injection Molding Industry           Pharmaceutical Industry           Plastic Packaging Industry               Printing Industry

 

 

Upport and Services:


Air Cooled Chiller technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables

 

 

Packing and Shipping:


Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.

 

 

When it comes to water-cooled screw double-head chillers, what are the advantages and features?


When it comes to water-cooled screw double-head chillers, what are the advantages and features:

1. High cooling capacity: Double-head chillers have higher cooling capacity, and they can provide greater cooling capacity than single-head chillers. This is useful for large buildings, factories or facilities that require large amounts of cooling.

 

2. Flexibility and adjustability: The dual-head chiller provides greater flexibility and adjustability. By controlling each machine head independently, the cooling capacity can be adjusted according to demand. This means that system operation can be flexibly adapted to changing load demands and environmental conditions to improve energy efficiency and responsiveness.

 

3. Energy saving and optimized operation: The dual-head chiller can achieve energy saving and optimized operation through the intelligent control system. Based on actual needs, the system can automatically choose to use one or two machine heads, and adjust the operating parameters of the machine heads to achieve optimal energy efficiency and performance.

 

4. Redundancy and reliability: The dual head configuration provides system redundancy. If one machine head fails or requires repair, the other machine head can continue to operate, ensuring system reliability and continuous cooling capacity. This redundant design helps reduce downtime and improves equipment reliability.

 

5. Control system and monitoring: Double-head chillers are usually equipped with advanced control systems and monitoring equipment. These systems can monitor and record key parameters such as temperature, pressure and energy consumption for real-time monitoring and fault diagnosis. This information can be used to optimize operations, predict maintenance and improve system performance.

 

6. Installation and Space Requirements: Double-head chillers generally require larger installation space because they have two independent heads. When planning and installing the system, factors such as its size, pipe connections and cooling water supply need to be taken into account.

 

The dual head chiller is an efficient, flexible and reliable refrigeration equipment suitable for large industrial and commercial applications. They offer the advantages of greater cooling capacity, flexible regulation and redundant operation to meet complex cooling needs. When selecting and operating a dual-head chiller, it is best to refer to the relevant product description and operating manual for accurate technical specifications and operating guidance.

Hot Products

Product Description: One of the key features of this Water-Cooled-Chiller is its protection system. ...
JLSF-75HP Air Cooled Water Chiller Using Denmark Danfoss Scroll Compressor Product Description: Air...
Product Description: Mold Cooling Water Chiller is a cooling equipment specially used in the mold ...
Product Description: Chillers are widely used in the beverage industry. As a common cooling ...
JLSF-100HP Air Cooled Water Chiller Using Denmark Danfoss Scroll Compressor Product Description: Air...
JLSF-25HP Air Cooled Water Chiller Space-Saving And Durable For Research Facilities Product ...