60HZ 220V R410a R22 Slim Wall Mounted Air Conditioner 12000BTU
Cooling Heating
CA Panel 60HZ 220V R410a/R22 12000BTU Cooling Heating High Quality
Wifi Control PCB 3 Year Warranty
Dehumidification
The air conditioner is accompanied by dehumidification during the
refrigeration process. The relative humidity of the environment
that people feel comfortable should be around 40-60%. When the
relative humidity is too high, such as above 90%, even if the
temperature is within a comfortable range, people still feel bad.
Purifying air
The air contains a certain amount of harmful gases such as NH3,
SO2, etc., as well as various odors such as sweat, body odor and
bathroom odor.
| | | | 12000BTU |
Model No. | TAC-12CS/Z | TAC-12CHS/Z |
| KF-35GW | KFR-35GW |
| 内820(Φ7×2)+780(Φ7.94×1) | indoor 820(Φ7×2)+outdoor 780(Φ7.94×1) |
Type | cooling only | Heating Pump |
Control type | | |
Rated cooling capacity | Btu/h;W | 12,000 | 11535;3381 |
Rated heating capacity | Btu/h;W | N.A | 12552;3679 |
EER for cooling | Btu/h.w; W/W | 10,2.9 | 2.7 |
COP for heating | W/W | N.A | 3.67 |
Moisture removal | Liters/h | 1 | 1.3 |
Pressure | High(DP) | MPa | 2.8 | 2.6 |
Low(SP) | MPa | 1.2 | 1 |
Indoor noise level at cooling | High | dB(A) | 41 | 41 |
Med. | dB(A) | 37 | 37 |
Low | dB(A) | 24 | 24 |
Outdoor noise level | dB(A) | 52 | 52 |
| | | | |
Power supply | | |
Voltage Range | V | 198~242 | 198~242 |
Rated current | Cooling | A | 5.6 | 5.8 |
Heating | A | N.A | 5.3 |
Rated input | Cooling | W | 1200 | 1253 |
Heating | W | N.A | 1163 |
Annual energy consumption | kwh (cooling) | | |
Max Current | Cooling | A | 7.3 | 9.8 |
Heating | A | N.A | N.A |
Max Power input | Cooling | W | 1560 | 1790 |
Heating | W | N.A | N.A |
| | | | |
Refrigerant/Charge | Gram | R22 | R22 |
Compressor | Type | Rotary | Rotary |
Model | / | C-RV212H92CB/QX-B217E030A |
LRA | A | / | / |
MFG | / | SANYO/GREE |
| | | | |
Indoor air circulation(Cooling/Heating) | m3/h | 530 | 530/530 |
Indoor fan type | Cross Flow | Cross flow |
Indoor fan speed H/M/L | Cooling | rpm | 1270/1170/1000 | 1290/1150/900 |
Heating | rpm | N.A | 1290/1150/900 |
Dry | rpm | 1000 | 900 |
Sleep | rpm | 1000 | 900 |
Indoor fan motor output | W | 12 | 13 |
Outdoor fan type | Propeller | Propeller |
Outdoor fan speed | rpm | 860 | 850 |
Outdoor fan motor output | W | 45 | 30 |
| | | | |
Connecting Pipe | Gas | mm | Φ12(1/2'') | Φ12 |
Liquid | mm | Φ6(1/4'') | Φ6 |
Connecting Wiring | Size x Core number | 1.0x3; 0.75x2 | 1.0*5 |
Drainage Pipe | | |
| | | | |
Suitable area | m2 | 15~23 | 12~23 |
Net dimensions (W x H x D) | Indoor | mm | 820x250x205 | 820x250x205 |
Outdoor | mm | 780x540x255 | 780x540x255 |
Net weight | Indoor | kg | 8 | 10.5 |
Outdoor | kg | 34 | 36 |
Packing dimensions (W x H x D) | Indoor | mm | 855x305x255 | 880*315*269 |
Outdoor | mm | 863x598x376 | 870*340*590 |
Gross weight | Indoor | kg | 10 | 11.5 |
Outdoor | kg | 38 | 38 |
Maintenance
Maintenance before starting up
Generally, household air conditioners are turned off in September
and then turned on from May to June of the following year. They
will not be used for more than half a year. Therefore, a
comprehensive "diagnosis" must be done before the air conditioner
is turned on to check whether the air conditioner is "faulty".
According to the results of the inventory, under the guidance of
professional and technical personnel, do a good job of maintenance
and cleaning. This time, the maintenance and cleaning should be
more in place. Including the casing, body, and filter of the
outdoor unit and the indoor unit, and then start trial operation to
observe the cooling speed and effect.
cleaning method
The cleaning of the air conditioner should include three parts:
First, the casing and exposed parts of the air conditioner body,
which are easily contaminated parts;
Second, filter cleaning is the most important part of the core;
Third, the condenser and evaporator part