12KV Three Phase 50HZ Smart Grid Devices 1250A Electrical Protection Devices

 

1. General Features of 12KV Three Phase 50HZ Smart Grid Devices 1250A Electrical Protection Devices

ZN12 -40.5 series indoor high voltage vacuum circuit breaker applied to power system that of 35KV three-phase AC 50HZ. It is using the longitudinal magnetic field contacts for the ceramic structure,the proliferation of breaking arc generated when current distribution in the contact on the same local melting phenomenon does not occur, but also has a low arc energy voltage (20-200V) and low chopping current (4-5A), and operate with high reliability organizations.

 

2. Environmental Condition of 12KV Three Phase 50HZ Smart Grid Devices 1250A Electrical Protection Devices

  • Altitude:not exceed 2000m
  • Ambient temperature:not higher than +40°C, not less than -10°C
  • Relative humidity:daily average relative humidity:≤95%;monthly average relative humidity≤90%;daily average saturated vapor pressure ≤2.2KPa;monthly average value ≤1.8KPa
  • Earthquake intensity:≤8 degree
  • The installation should be free from fire,explosion,severe vibration,chemical corrosion and serious pollution

3. Technical Data of 12KV Three Phase 50HZ Smart Grid Devices 1250A Electrical Protection Devices

 

No.ItemUnitData
1Rated voltageKV40.5
2Rated currentA1250,1600,2000,2500,3150
3Rated frequencyHZ50
4Rated short time with stand currentKA25,31.5
5Rated short-circuit breaking current times 20
6Mechanical lifetimes30000
7Rated lightning impulse with stand voltageKV185
8Rated operating sequence O-0.3S-CO-180S-CO
9Raged voltage of closing and opening electromagnetVAC/DC220,110
10Rated voltage of no-voltage releaseVAC/DC220,110
11Rated short-duration power frequency withstand voltage (1min)KV95
12Opening timems30≤t≤75
13Closing timems30≤t≤65
14Energy storage times≤15

 

Hot Products

24VDC 220V Power Distribution Feeder Remote Terminal Unit Hanging FTU 24VDC 220V Power Distribution ...
220V 10 Ways 24VDC Smart Grid Devices Unit FTU Intelligent Power Distribution General of 220V 10 ...
2000m Altitude 12kV Electrical Protection Devices 1260kW Intelligent Power Generation 1. General ...
12KV Three Phase 50HZ Smart Grid Devices 1250A Electrical Protection Devices 1. General Features of ...
Low Voltage 35 Kv XGN Lightning Electrical Surge Arrester Low Voltage 35 Kv XGN Lightning Electrical ...
Power High Voltage 72.5kv 50Hz Electrical Surge Arrester 100A Main Characteristics of Power High ...