Fused Outdoor 12kv 3000m Sea Level HV Disconnect Switch 50hz

Fused Outdoor 12kv 3000m Sea Level HV Disconnect Switch 50hz​ Using Environment 
1. The temperature in surrounding air: Max:+40°C~Min -15°C,The average:<=+35°C
2. Humidity: The average of relative temperature within 24hours is <=95%, The average of Water
vapour pressure within 24hours is <=2.2kpa.
3. Here is no serious pollution from dust, smoke,corrosive or combustible gas,
vapor or salt spray, and so on.


Fused Outdoor 12kv 3000m Sea Level HV Disconnect Switch 50hz​ Service Condition
1. The altitude does not exceed 1000m.
2. The ambient air temperature: Highest:+40oC, the lowest:-10oC
3. The relatire Humidity of air not bigger 90% (around the 25oC envirenment)
4. The working situation have no conductivity dust.
5. The working situation have no corrosive gas of affect insulation and destroy metal.
6. The working situation without violent vibration and striking.
7. The working situation have no explosive danger and fire.


Fused Outdoor 12kv 3000m Sea Level HV Disconnect Switch 50hz​ Technical Parameter

No.ItemunitParameter
1Rated VoltagekV12
2Max. Working VoltagekV12
3Rated FrequencyHz50
4Rated CurrentA100
5Rated Short-circuit Switch-off CurrentkA50
61min Power Frequency Withstand voltage(value), to ground, interphase/isolation breakkA42/48
7Lighting Impluse Resisting Voltage (peak) to ground, interphase/isolation breakkV75/85
8Fuse Link Striking Output EnergyKg≈5
Technical Parameter of load switch with fuse
No.ItemUnitParameter
1Rated VoltagekV12
2Max. Working VoltagekV12
3Rated FrequencyHz50
4Rated CurrentA630
5Rated Power load switch-off currentA630
65% rated power load switch-off currentA31.5
7Rated capacity switch-off currentA10
8Rated inductance switch-off currentA40
9Rated transfer currentkA1.3
10Rated short-time withstand currentkA20
11Rated peak withstand currentkA50
12Mechanical endurancecycle2000


 

 

Hot Products

GW4 Three - Phase Outdoor AC HV Disconnecting Switch 126KV with Earthing Switch Description of GW4 ...
35kv High Voltage Monopole Type Disconnect Switch / Power Isolator In Outdoor General GW4-40.5 ...
Fused Outdoor 12kv 3000m Sea Level HV Disconnect Switch 50hz Fused Outdoor 12kv 3000m Sea Level HV ...
35KV 3 Phase 630A 3000M Altitude 4S Outdoor Disconnect Switch Main Characteristics of 35KV 3 Phase ...
Electrical Anti Electrodynamic Space Saving GT10 HV Disconnect Switch 1250A Electrical Anti ...
Single Pole Fused Disconnect Switch Electricity Isolation Overview GW22 (GT8)-126D/1600-31.5 ...