Three Phase Monitoring Electronic Overload Relay For Lifts Elevators

 

Setting method

 

1. First adjust the knob clockwise to the max. Start the motor until the motor is in normal operating condition.


2. Then slowly adjust the knob anti-clockwise till the overload indicatorlights up, so the protector is just in a critical state of overload.


3. After that slowly adjust the knob clockwise till the overload indicatorgoes out,setting completed.

 

 

Features

 

 

1) Integrative structure

 

2) Three-phase monitoring of overload, phase loss, phase unbalance

 

3) Powered by the measuring circuit

 

4) 1 NC SCR output contact

 

5) 4 LEDs for status indication

 

 

Protecive Functions

 

1) Overload

2) Phase Loss

3) Phase Unbalance

 

 

Technical data

 

ModelJDB-1
Input Circuit=Measuring CircuitL1,L2,L3
Current Range

2.5-5A,4-10A,8-20A,16-40A

32-80A,63-160A,150-320A,50Hz

Monitoring FunctionsOverload,Phase Loss,Phase Unbalance
Setting MethodBy Knob
Startup Delay5s,10s,20s(10s default)
Delay Time For OverloadInverse Time 80s~10s for 1.2~5 Times
Phase Unbalance Threshold≥50% Unbalance Ratio

Delay Time for Phase Loss and

Phase Unbalance

≤1s
Reset Time60±10s,Reset By Power Cycle
Applicable Voltage RangeAC24V~380V,50Hz
IndicatorsABC Overload and Phase Loss
Output Contacts1NC (SCR Output)
Contact Capacity1A 380VAC(Resistive Load)
Degree of ProtectionIP 20
Working Conditions-25℃~65℃,≤85%RH,Non-condensing
Mechanical Durability1000000 Cycles
Dielectric Strength>2KVAC 1Min
Weight200g
Dimension

2.5-40A:38*90*63mm

80~300A:44.5*123*67mm

MountingScrew Fixing
 

 

Hot Products

MOSFET Output 4 6 8 12 16 Channel Transistor Module NPN/PNP Input DC24V The transistor's response ...
0.1-10A Electronic Overload Relay Compressors motor protection relays Description Diemensions:70*67...
Undercurrent Electronic Overload Relay Current Protection Relays Specification The Appearance for ...
380VAC Electronic Overload Relay Motor Protective Meter Over Current Monitor Applications: 1. Pumps ...
Three Phase Monitoring Electronic Overload Relay For Lifts Elevators Setting method 1. First adjust ...
Separate Structure Electronic Overload Relay Earth Fault 4-20mA Analog Output Advantage 1) ...