Home Companies Changzhou Victory Technology Co., Ltd

JP JN 0.12-8mm Custom J Type Thermocouple Bare Wire

Changzhou Victory Technology Co., Ltd

Contact Us

[China] country

Trade Verify

Address: NO.32 West Taihu Road, Xinbei District, Changzhou, Jiangsu

Contact name:Jane

Inquir Now

Changzhou Victory Technology Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

JP JN 0.12-8mm Custom J Type Thermocouple Bare Wire

Country/Region china
City & Province changzhou jiangsu
Categories Billets
InquireNow

Product Details

Introduction:


 

Type J thermocouple bare wire is a commonly used thermocouple type used for temperature measurement and control. Iron-copper-nickel thermocouple (J-type thermocouple) is also called iron-constantan thermocouple. The nominal chemical composition of its positive electrode (JP) is pure iron.
The negative electrode (JN) is a copper-nickel alloy, often vaguely called constantan. Its nominal chemical composition is 55% copper and 45% nickel, as well as a small but very important amount of cobalt, iron, manganese and other elements. Although it is called Constantan, but is different from nickel-chromium-constantan and copper-constantan, so it cannot be replaced by EN or TN.
Iron-Constantan thermocouples cover the measurement temperature range from -210 to 1200°C, but are typically used in the temperature range 0-750°C.


J-type thermocouple bare wire is widely used in industrial control fields, including heating equipment, furnace temperature monitoring and heat treatment processes. It is also widely used in environmental monitoring, such as weather stations, greenhouses and warehousing environments. In scientific research and laboratories, J-type thermocouple bare wires are often used to measure sample temperature and conduct thermodynamic experiments.

One of the advantages of Type J thermocouple bare wire is its corrosion resistance, enabling temperature measurement in some humid and corrosive environments. In addition, J-type thermocouple bare wire has fast temperature response capability and can quickly respond to temperature changes.

 

 

Characteristic:


  • Thermocouple material: J-type thermocouple bare wire is composed of ferritic stainless steel (Fe-Cr-Al alloy) and copper-nickel alloy (Constantan). Fe-Cr-Al alloy is the positive electrode of J-type thermocouple, and Constantan is the negative electrode.
  • Temperature range: Type J thermocouple bare wire is suitable for medium temperature ranges, typically measuring temperatures from -40°C to 750°C (-40°F to 1382°F).
  • Linear characteristics: J-type thermocouple bare wire has good linear characteristics within its operating temperature range and can provide relatively accurate temperature measurements.
  • Low drift: J-type thermocouple bare wire has low drift characteristics and can maintain relatively stable temperature measurements.

 

Advantage:


  • Widely used: J-type thermocouple bare wire is one of the commonly used thermocouple types and is widely used in industrial control and laboratory environments.
  • Corrosion resistance: J-type thermocouple bare wire has good corrosion resistance and is suitable for temperature measurement in some humid and corrosive environments.
  • Fast response: J-type thermocouple bare wire has fast temperature response capability and can quickly reflect temperature changes.

 

Relevant specific parameters:


  1. Temperature range: -40°C to 750°C (-40°F to 1382°F)
  2. Thermoemf output: Varies based on temperature changes, usually in the microvolt (μV) level.
  3. Linear characteristics: has good linear characteristics.
  4. Sensitivity: Varies based on specific model and manufacturer.
Code
Wire Component of the thermocouple
+Positive leg
- Negative Leg
N
Ni-Cr-Si(NP)
Ni-Si-magnesium (NN)
K
Ni-Cr(KP)
Ni-Al(Si) (KN)
E
Ni-Cr(EP)
Cu-Ni (EN)
J
Iron (JP)
Cu-Ni (JN)
T
Copper (TP)
Cu-Ni (TN)
B
Platinum Rhodium-30%
Platinum Rhodium -6%
R
Platinum Rhodium-13%
Platinum
S
Platinum Rhodium -10%
Platinum
  • ​Standards
ASTMANSIIECDINBSNFJISGOST
(American Society for Testing and Materials) E 230(American National Standard Institute) MC 96.1(European Standard by the International Electrotechnical Commission 584)-1/2/3(Deutsche Industrie Normen) EN 60584 -1/2(British Standards) 4937.1041, EN 60584 - 1/2(Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324(Japanese Industrial Standards) C 1602 - C 1610(Unification of the Russian Specifications) 3044

 

 

Using Occastion of Different Thermocouple
Thermocouple Type
Working Atmosphere
Working Temperature
Type K
KP
Oxidizing
-200 to +1200℃
KN
Inert
Type N
NP
Oxidizing
-200 to +1200℃
NN
Oxidizing
Type E
EP
Oxidizing
-200 to +900℃
EN
Oxidizing
Type J
JP
Oxidizing(use in high temp)
-40 to +750℃
JN
Reducing, Inert, Vacuum
Type T
TP
Oxidizing,Vacuum
-200 to +350℃
TN
Reducing, Vacuum

 

  • Working temperature:

 

Diameter/mmLong time WorkingShort period Working
temperature/°Ctemperature/°C
0.3,0.5300400
0.8,1.0,1.2400500
1.6,2.0500600
2.5,3.2600750

 

 

contact us

email:victory@dlx-alloy.com

Oem service:
Welcome customized size
We are experience factory for OEM&ODM service

 

Specific application areas:


  1. Industrial control: J-type thermocouple bare wire is widely used in industrial control fields, including heating equipment, furnace temperature monitoring, heat treatment processes, etc.
  2. Laboratory research: J-type thermocouple bare wire is widely used in scientific research and laboratories for measuring sample temperature, thermodynamic experiments, etc.
  3. HVAC system: J-type thermocouple bare wire can be used for temperature monitoring in HVAC systems, such as temperature control, environmental monitoring, etc.

 

 

Q&A:


What is the temperature range of J-type thermocouple bare wire?
Answer: The temperature range of J-type thermocouple bare wire is usually between -40°C and 750°C.

 

What are the advantages of J-type thermocouple bare wire?
Answer: J-type thermocouple bare wire has the advantages of wide application, corrosion resistance and fast response.

 

What applications are J-type thermocouple bare wire suitable for?
Answer: J-type thermocouple bare wire is suitable for applications such as industrial control, laboratory research, and HVAC systems.

Hot Products

The Thermocouple bare wire product series provides a variety of models and specifications, including ...
The Thermocouple bare wire product series provides a variety of models and specifications, including ...
The Thermocouple bare wire product line includes a variety of models (such as K-type, J-type, T-type ...
Introduction: K-type thermocouple bare wire is a commonly used thermocouple type, consisting of K...
Introduction: Type E thermocouple bare wire is a commonly used thermocouple type used for temperatur...
Introduction: Type J thermocouple bare wire is a commonly used thermocouple type used for temperatur...