Home Companies XI'AN BEICHENG ELECTRONICS CO.,LTD

Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100

XI'AN BEICHENG ELECTRONICS CO.,LTD
Active Member

Contact Us

[China] country

Address: JINGYUAN 7 ROAD, JINGHE INDUSTRIAL PARK, NORTH DISTRICT,XI'AN,CHINA  710200

Contact name:sales

Inquir Now

XI'AN BEICHENG ELECTRONICS CO.,LTD

Digital Multimeter Process Calibrator Signal Source CAT IV 600V With 40MΩ Resistance RTD RSKEJTNB Cu50 Pt100

Country/Region china
Categories Solar Chargers
InquireNow

Product Details

VICTOR 79 Digital Multimeter 2 In 1 4-20mA Signal Output Multimeter Process Signal Source 40MΩ RTD RSKEJTNB Cu50 Pt100

 

Specifications

All the speculations apply to +18℃to +28℃, 10% to 70%RH unless stated otherwise.

All speculations assume a 5- minute warm- up period.

Standard speculation is valid for one year.

 

DC Voltage Measurement

Range(DC V)ResolutionAccuracy,+( % of reading +counts)
4.000V0.001V0.2%+4
40.00V0.01V0.2%+4
400.0V0.1V0.2%+4

Measuring Impedance:10 MΩ(nominal),<100pF

Common mode rejection ratio: 50Hz or 60Hz > 100dB

Normal mode rejection ratio: 50Hz or 60Hz > 45dB

Overvoltage protection: 600Vp-p

 

DC mV Measurement

Range(DC mV)ResolutionAccuracy,+( %reading +counts)
40.00mV0.01 mV0.5%+6
400.0mV0.1 mV0.2%+4

Measuring Impedance: 10 MΩ(nominal)

Overvoltage protection: 600Vp-p

 

TC Measurement

Range(type)Set RangeResolutionAccuracy+(%reading +counts)
R-40~1760℃1℃

0.5%+3(≤100℃)

0.5%+2(>100℃)

S-20~1760℃1℃

0.5%+3(≤100℃)

0.5%+2(>100℃)

B400~1800℃1℃

0.5%+3(≤600℃)

0.5%+2(>600℃)

E-200~500℃1℃

0.5%+2(≤-100℃)

0.5%+1(>-100℃)

K-200~950℃1℃

0.5%+2(≤-100℃)

0.5%+1(>-100℃)

J-200~700℃1℃

0.5%+2(≤-100℃)

0.5%+1(>-100℃)

T-200~400℃1℃

0.5%+2(≤-100℃)

0.5%+1(>-100℃)

N-200~1000℃1℃

0.5%+2(≤-100℃)

0.5%+1(>-100℃)

By using ITS-90 temperature scale

Note: The accuracy does not include the error of internal temperature compensation caused by a sensor. The range of the internal temperature compensation sensor is + 2℃.

 

AC Voltage Measurement

Range(ACV)Resolution

Accuracy,+( %reading +counts)

40~400Hz

400.0mV0.1mV1.0%+4
4.000V0.001V0.5%+4
40.00V0.01V0.5%+4
400.0V0.1V0.5%+4

Specifications are valid from 5% to 100% of amplitude range

400mV is only confined to manual range

AC conversion: average value

Measuring Impedance: 10 MΩ(nominal),<100pF

Common mode rejection ratio: 50Hz or 60Hz > 100dB

Overvoltage protection: 600Vp-p

DC Current Measurement

Range(DC mA)ResolutionAccuracy,+( %reading +counts)
40.00mA0.01 mA0.2%+4
400.0 mA0.1 mA0.2%+4

Overload protection: 0.5A,250V fast-blow fuse

Measuring Impedance: 1Ω

 

AC Current Measurement

Range(AC mA)Resolution

Accuracy,+( %reading +counts)

40~400Hz

40.00mA0.01 mA0.5%+4
400.0 mA0.1 mA0.5%+4

Specifications are valid from 5% to 100% of amplitude range

Overload protection: 0.5A,250V fast-blow fuse

Measuring Impedance: 1Ω

 

Resistance Measurement

RangeResolutionAccuracy,+( %reading +counts)
400.0Ω0.1Ω0.2%+4
4.000kΩ0.001kΩ0.2%+4
40.00kΩ0.01kΩ0.2%+4
400.0kΩ0.1kΩ0.2%+4
4.000MΩ0.001 MΩ0.5%+4
40.00 MΩ0.01 MΩ1%+4

Open circuit voltage:0.4v

Guide lead resistance is excluded in the accuracy

Overvoltage protection: 600Vp-p

 

 

RTD Measurement

Range(type)Input RangeResolutionAccuracy,+( %reading +counts)
Pt100-200~700℃1℃0.5%+2
Cu50-50~150℃1℃0.5%+4

By using Pt100-385 temperature scale

Measuring current 1 mA

Note: attached lead resistance is excluded

 

 

Frequency Count Accuracy

RangeResolutionAccuracy,+( %reading +counts)
50.00Hz0.01Hz0.1%+3
500.0Hz0.1Hz0.1%+3
5.000KHz1Hz0.1%+3
50.00KHz0.01KHz0.1%+3
100.0KHz0.1KHz0.1%+3
Display updates 3 times/second (at >10Hz)

Diode Test and Continuity Test

Diode test indication:

Displays voltage drop across device, open circuit voltage: 1.1v-1.6v; short circuit current:<0.2 mA(typical value). Accuracy+ (2%reading +1count)

Continuity test indication:

Continuous audible tone for test resistance<50

Open circuit voltage: <0.45v

Short circuit current:130μA typical

Overload protection: 600V(peak)

 

Technical Data 

 

ProjectVICTOR 77VICTOR 78VICTOR 79
MeasurementDC voltageRange±51V±400V±400V
The highest
resolution
10mV0.01mV0.01mV
Basic accuracy0.5%0.2%0.2%
AC voltageRange`510V400V400V
The highest
resolution
100mV0.1mV0.1mV
Basic accuracy1.5%0.5%0.5%
ResistanceRange5kΩ40MΩ40MΩ
The highest
resolution
0.1Ω0.1Ω
Basic accuracy0.5%0.2%0.2%
DC currentRange±22mA±400mA±400mA
The highest
resolution
1uA10uA10uA
Basic accuracy0.2%0.2%0.2%
AC currentRangeN/A400mA400mA
The highest
resolution
10uA10uA
Basic accuracy0.5%0.5%
ThermocoupleRangeN/AN/AR,S,B,E,K,J,T,N
The highest
resolution
1°C
Basic accuracy0.5%
RTDRangeN/AN/ACu50,Pt100
The highest
resolution
1°C
Basic accuracy0.5%
CAPRangeN/AN/AN/A
The highest
resolution
Basic accuracy
FrequencyN/A10Hz~100kHz10Hz~100kHz
Diode test
Continuity beeper
Data hold
Relative value measurementN/A
SourceDC voltageRangeN/A-50.0mV~550.0mV
-0.500V~5.500V
-10.00mV~110.00mV
-0.5000V~5.5000V
Resolution0.1mV,1mV0.01mV,0.1mV
Basic accuracy0.2%0.2%
ResistanceRangeN/AN/A0~400.0Ω
Resolution0.1Ω
Basic accuracy0.2%
DC currentRange22mA22mA22mA
Resolution0.001mA0.01mA0.001mA
Basic accuracy0.2%0.2%0.2%
Simulating transmitter
25%,100%Step output
Automatic rampN/A
Automatic stepN/A
Display current and % of span
Loop power24V15V15V
FrequencyN/A1.0Hz~11.0kHz1.0Hz~11.0kHz
ThermocoupleN/AN/AR,S,B,E,K,J,T,N
RTDN/AN/ACu50,Pt100
Loop detectionThe 24V loop power supply and measuring the currentN/AN/A
Built in 250 Ω
HART loop resistance
N/AN/A
Power Supply2×1.5V AA Alkaline battery4×1.5V AAA Alkaline battery4×1.5V AAA Alkaline battery
Auto Power-off
BacklightN/A
SafetyCAT Ⅳ 600V,
Pollution degree 2
CAT Ⅲ 600V ,
Pollution degree 2
CAT Ⅲ 600V,
Pollution degree 2
Size180×90×52205×95×42205×95×42
WeightAbout 400gAbout 500gAbout 500g
AccessoriesTest line, manual,fuseTest line, manual,fuseTest line, manual,fuse
Standard Quantity Per Carton10pcs10pcs10pcs
Standard Carton Measurement395mm*385mm*260mm395mm*385mm*260mm395mm*385mm*260mm
Standard Carton Cross Weight8.8Kg9.8Kg10.2Kg

 

Hot Products

VICTOR 10 Non-contact AC Voltage Detector meter LCD Display NCV Sensitivity Alarm Electric Circuit ...
VICTOR 88C Manual Range Digital Multimeter 1999 Counts large LCD Display With True RMS 1000V/20A AC ...
VICTOR 79 Digital Multimeter 2 In 1 4-20mA Signal Output Multimeter Process Signal Source 40MΩ RTD ...
2 In 1 Pocket Digital Multimeter Process Signal Source Voltage Current Frequency VICTOR 78 Digital ...
5999 Counts NCV VICTOR Digital Multimeter Flashlight Backlight Data Hold With Live Test VICTOR 890H ...
Digital Pocket Analog Multimeter 10A 1000V With Resistance Function VC3010 Analog Multimeter Large ...