Home Companies Shenzhen Veikong Electric Co., Ltd.

99% MPPT VFD Solar Pump Inverter 1.5kw To 11kw For Pumping System

Shenzhen Veikong Electric Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China

Contact name:Terry

Inquir Now

Shenzhen Veikong Electric Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

99% MPPT VFD Solar Pump Inverter 1.5kw To 11kw For Pumping System

Country/Region china
City & Province shenzhen
Categories Electrical Ceramics
InquireNow

Product Details

99% MPPT VFD Solar Pump Inverter 1.5kw To 11kw For Pumping System

 

DC AC MPPT Solar Pump Inverter 1.5kw 2.2kw 4kw 5.5kw 7.5kw 11kw VFD

 

 
VEIKONG VFD500-PV solar pumping inverter is specially designed for watering system. A high converting efficiency of 99% and advanced MPPT technology make the solar energy fully used. It converts DC power into AC to drive all kinds of motors. The intelligent design protects the pumps from many abnormal cases, such as over-loading, over-voltage, dry-running, over-heating,low frequency and et
 
● Easy to use
 
Simply connect the photovoltaic panel to the inverter, no need to set any parameters, and the PV pump can be automatically started after power-on
 
● Multiple protection measures It has protection functions such as PV over-voltage protection, PV polarity reverse connection alarm, over-temperature automatic derating, etc., which can effectively extend the life of the product
 
● Advanced MPPT algorithmEnsure solar power tracking efficiency can reach 99%
 
● GPRS remote monitoringSupports optional GPRS module, which can realize remote monitoring function of computer webpage and mobile APP
 
● AC/DC switching schemeAll series of products can realize automatic switching of PV DC input and grid AC input, which can meet 24 hours of no care work
 

1. How to achieve Automatic start after stop?

If it is controlled by keyboard no need to set any parameter. If you want to control by external switch

As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop

 

2.If pump is 60HZ frequency, how to set max frequency?

Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.

Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single phase with capacitor ,set P00.11=22;If your motor is single phase without capacitor ,set P00.11=32

 
 
 
 
 
 
 

Electrical Specifications

 

 

220V

380V

Max input DC voltage

450V

810V

DC voltage range

150~450VDC

300~810VDC

Normal working DC voltage

260V-400V

400V-650V

Recommended input mppt voltage

330V

550V

MPPT efficiency

>99%

Rated output voltage

1/3-phase 220VAC

3-phase 380-480VAC

Output frequency range

50/60Hz

Max efficiency of the machine

99%

Ambient temperature range

-10 °C~50 °C, derating if the temperature is above 40 °C

Cooling method

Air cooling

Protection degree

IP20/IP21

Altitude

Below 1000m; above 1% for every additional 100m.

Standard

CE/ROHS

 

 

 

Accessories:

 

1. GPRS (support 2g/3g/4g internet)

 

2. Output reactor

 

3. LCD keypad

 


 

VEIKONG study famous brands inverter advantages



 


 

 

For 220V single phase motor connection

1: Single phase asynchronous motor wiring method (without starting capacitor):

Notice: U is connected to the common end of the starting winding and the working winding, V is connected to the starting winding, and W is connected to the working winding;

 

Single-phase asynchronous motor if the rotary steering is not correct, you can change the V and W wiring or set P22.13=1.

 

First solution: Set parameter P11.01=1 (Single phase motor type without capacitor) or second solution: set P00.11=31 if your motor frequency is 50 hz or set P00.11=32 if your motor frequency is 60HZ

 

 

For 220V single phase motor connection

2: Single-phase asynchronous motor wiring method (with capacitor)

 

Notice1: First solution: Connect motor cable to power terminal U and V and enter BSC mode to Set parameter P23.15=0(output phase loss shielding protection) or second solution: set macro P00.11=21 if your motor frequency is 50HZ or set P00.11=22 if your motor frequency is 60HZ

 

 

 

 

Hot Products

AC 380v 220v IP20 OVP VFD Variable Frequency Drive Manufacturers 30kw 40hp variable frequency drive ...
VFD Variable Frequency Inverter For Heavy Load 30kw 37kw 45kw 55kw VFD ac drive frequency inverter ...
380V Input VFD Variable Frequency Drive 0.75kw To 710kw Three Phase AC drive vfd variable speed ...
7HP 10HP 15HP 25HP 30HP Frequency Inverter AC Drive With Vector Control Product Advantages 1, With ...
560KW 630KW 710KW Frequency Drive For AC Motor Crusher Machine High performance 1. More Accurate ...
400KW 450KW 500KW AC Drive VFD Work For Big Motor Automation Machines Performance features Advanced ...