400KW 450KW 500KW AC Drive VFD Work For Big Motor Automation Machines

 

 

 

Performance features
 
  • Advanced motor control algorithm
  •  
  • High performance open loop vector control
  •  
  • Optimal V/F,and vector control mode
  •  
  • Excellent ramp slope control
  •  
  • Fast autotune (less than one minute)
  •  
  • Overload: 150% rated output current, one minute

 

Hardware features

 

  • Dual CPU processing, more precise control
  •  
  • Using the latest generation IGBT
  •  
  • 0.4k~22kW with standard inner brake unit
  •  
  • Inner EMC C3 filter with breakpoint design, convenient for access and disconnection, meet different
  •  
  • PCBA coating process, increase environment adaptability
  •  
  • Unique control terminals: simple electronic switch set to complete the conversion between source and sink of I/O terminals
  •  
  • Reference (current) loose, trip or not could be selected
  •  
  • IGBT thermal design
  •  
  • Wireless fan block design, easy to replace or maintain
  •  
  • Connecting auxiliary fan makes the drive suitable for worse environment

 

Technical Specifications

 

ItemSpecification
InputInput Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

Allowed Voltage fluctuation range-15%~10%
Input frequency50Hz / 60Hz,fluctuation less than 5%
OutputOutput Voltage3phase:0~input voltage
Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

ControlControl mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

Operating modeSpeed control,Torque control(SVC and VC)
Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

Frequency range

0.00~600.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

V/f curve

V / f curve type: straight line, multi point, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

DC bus voltage control

Over-voltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;

 

Under-voltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure

 

VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

Vdc Min control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump under-voltage fault

Carrier frequency1kHz~12kHz(Varies depending on the type)
Startup methodDirect start (can be superimposed DC brake); speed tracking start
Stop methodDeceleration stop (can be superimposed DC braking); free to stop
Main control functionJog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN
FunctionKeypadLED Digital keyboard and LCD keypad(option)
Communication

Standard:

MODBUS communication

CAN OPEN AND PROFINET( IN DEVELOPMENT)

PG cardIncremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card
Input terminal

Standard:

5 digital input terminals, one of which supports high-speed pulse input up to 50kHz;

2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input;

Option card:

4 digital input terminals

2 analog input terminals.support-10V-+10V voltage input

Output terminal

standard:

1 digital output terminal;

1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output;

1 relay output terminal(second relay is an option )

2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output;

Option card: 4 digital output terminals

ProtectionRefer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function
EnvironmentInstallation locationIndoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
Altitude0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m
Ambient temperature-10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C
HumidityLess than 95%RH, without condensing
VibrationLess than 5.9 m/s2 (0.6 g)
Storage temperature-20°C ~ +60°C
OthersInstallationWall-mounted, floor-controlled cabinet, transmural
Protection levelIP20
cooling methodForced air cooling
EMCCE ROHS

Internal EMC filter

Complies with EN61800-3

Category C3

3rd Environment

 

 

Model Range

 

Model

Power capacity

(KVA)

Input current

(A)

Output current(A)

Adaptable Motor

(KW)

SIZEBrake Unit
Heavy loadLight load
Three phase: 380-480V,50/60Hz
VFD500-R75GT4B1.53.42.54.20.75SIZE AInternal
VFD500-1R5GT4B354.25.61.5
VFD500-2R2GT4B45.85.69.42.2
VFD500-4R0G/5R5PT4B5.910.59.413.03.7
VFD500-5R5G/7R5PT4B8.914.613.017.05.5SIZE B
VFD500-7R5G/011PT4B1120.517.023.07.5
VFD500-011G/015PT4B1726.025.031.011SIZE CInternal
VFD500-015G/018PT4B2135.032.037.015
VFD500-018G/022PT4B2438.537.045.018.5SIZE D
VFD500-022G/030PT4B3046.545.057.022
VFD500-030G/037PT44062.060.075.030SIZE Eoption
VFD500-037G/045PT45076.075.087.037
VFD500-045G/055PT46092.090.0110.045SIZE F
VFD500-055G/075PT475113.0110.0135.055
VFD500-075G/090PT4104157.0152.0165.075SIZE G
VFD500-090G/110PT4112170.0176.0210.090External
VFD500-110G/132PT4145220.0210.0253.0110SIZE H
VFD500-132G/160PT4170258.0253.0304.0132SIZE I
VFD500-160G/185PT4210320.0304.0360.0160
VFD500-185G/200PT4245372.0360.0380.0185SIZE J
VFD500-200G/220PT4250380.0380.0426.0200
VFD500-220G/250PT4280425.0426.0465.0220SIZE K
VFD500-250G/280PT4315479.0465.0520.0250
VFD500-280G/315PT4350532.0520.0585.0280SIZE L
VFD500-315G/355PT4385585.0585.0650.0315
VFD500-355G/400PT4420638.0650.0725.0355SIZE M
VFD500-400G/450PT4470714.0725.0820.0400
VFD500-450G/500PT4530800.0820.0/450SIZE N
VFD500-500G/560PT4580880.0900.0/500
VFD500-560G/630PT4630950.0980.0/560SIZE O
VFD500-630GT471010801120./630SIZE O
VFD500-710GT479012001260/710SIZE O
Single phase :220V ,50/60HZ
VFD500-R40GS21.36.03.25.60.4SIZE AInbuilt
VFD500-R75GS22.411.05.68.00.75SIZE A
VFD500-1R5GS23.515.08.010.61.5SIZE A
VFD500-2R2GS25.525.010.614.02.2SIZE A
VFD500-4R0GS27.735.017.023.04.0SIZE B
VFD500-5R5GS28.953.025.031.05.5SIZE C
VFD500-7R5GS21167.032.037.07.5SIZE C
 

Product Application

 

 

 

Hot Products

7HP 10HP 15HP 25HP 30HP Frequency Inverter AC Drive With Vector Control Product Advantages 1, With ...
560KW 630KW 710KW Frequency Drive For AC Motor Crusher Machine High performance 1. More Accurate ...
400KW 450KW 500KW AC Drive VFD Work For Big Motor Automation Machines Performance features Advanced ...
IP20 VFD 280KW 315KW 355KW Frequency Inverter With LCD Keyboard Multifunctional and user friendly ...
VFD variable frequency inverter For Heavy Load 55kw 75kw 90kw 110kw VEIKONG hot selling VFD VFD500M ...
22KW 30KW 37KW 45KW VFD AC Drive Manufacturer Vector Control Shenzhen Veikong Electric CO.,Ltd. a ...