Home Companies ERFA Industries Group

ERFA-24 Electrical VCB Circuit Breaker 3 Poles With Common Insulated Cylinder

ERFA Industries Group
Active Member

Contact Us

[China] country

Address: Modern enterprise Central (east zone)

Contact name:Linda Dong

Inquir Now

ERFA Industries Group

ERFA-24 Electrical VCB Circuit Breaker 3 Poles With Common Insulated Cylinder

Country/Region china
Categories Battery Chargers
InquireNow

Product Details

Basic Info.

 

Model NO.:ERFA-24
Breaking Capacity:High Voltage Circuit Breakers
Operation:Electric Type
Speed:High-Speed Circuit Breaker
Arc-extinguishing Medium:Vacuum
Installation:Insert
Structure:MCCB
Poles Number:3
Type:Circuit Breaker
Function:Circuit-Breaker Failure Protection
Certification:VDE, ISO9001-2000, CE, CCC
Rated Current:630/1250/1600/2000/2500/3150A
Rated Voltage:24kv
Rated Frequency:50Hz
Insulated Cylinder:Embedded Poles
Mechanism Type:Mkl
Export Markets:Global
 
 

Product Description

 

ERFA-24  Series of Indoor High Voltage Vacuum Circuit Breaker
                 with Common Insulated Cylinder 

General Description
ERFA-24 series of Indoor High Voltage Vacuum Circuit Breaker with Common Insulated 
Cylinder is threephase A.C.50Hz indoor power distribution equipment with the rated
 voltage of 24KV.It
's used for protecting and controlling the electrical equipment in the 
fileds of industry & minning enterprise,power plants and substation.This type Vacuum 
Circuit Breaker conforms to national standards and the stipulation of IEC standard,the 
capability reaches grade of M2-E2-C2.

The product adopt composite insulation way,spring charged operation and screw rod 
push mechanism, with the characeristics of small volume,compact design and reliable 
operation, it can easily match with the switchgear and meet the 
"Five Preventions"
demands.
This kind of Vacuum Circuit Breaker can be used for many kinds of switchgear like KYN28-24(GZS1),This series of products include:VCB truck,isolation truck and fuse truck etc.
Applying ambient conditions
1. Ambient temperature:-15ºC~+40ºC.
2. Ambient humidity:the average humidity of a day should be no more than 95%;the average humidity of a month should be no more than 90%.
3. Earthquake intensity:not exceed 8 degrees.
4. Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa;the average pressure of a month should be no more than 1.8kPa.
5. The height above sea level:1000m(besides the special requirements).
6. It should be installed in the places without fire,explosion,serious filth,chemical erosion and violent vibration.
Main Technical Specification
S.NNameUnitData
1Rated voltagekV24
2Rated currentA63012501600200025003150
3Rated frequencyHz50
4Rated short circuit breaking currentkA202531.5
5Rated short circuit making currentkA506380
6Rated short time withstand currentkA202531.5
7Rated peak withstand currentkA506380
8Rated power frequency withstand voltagekV65
9Rated lighting impulse withstand voltagekV125
10Rated short-circuit durations4
11Rated operating sequence O-0.3s-CO-180s-CO
12DC component 50%
13Mechanical enduranceCycle10000
Vib-24 Indoor Hv Vacuum Circuit Breaker with Common Insulated Cylinder

 






















Hot Products

Product Description ZN85 40.5 vacuum circuit breaker 1, indoor type 2, 3phase 3, rated voltage: 40...
Vacuum Circuit Breakers (ZN73-12 (VS1)) ZN73 indoor AC high-voltage vacuum breaker is applicable to ...
Vacuum Circuit Breakers (ZN73-12 (VS1)) ZN73 indoor AC high-voltage vacuum breaker is applicable to ...
VFC- 7.2/12kv Indoor High Vacuum contactor-Fuse Combinations VFC middle-placed vacuum Contactor-fuse ...
Basic Info. Model NO.:ERFA-24 Breaking Capacity:High Voltage Circuit Breakers Operation:Electric ...
Product Description ZN85 40.5 vacuum circuit breaker 1, indoor type 2, 3phase 3, rated voltage: 40...