Insulated Fixed 630A VS1 VCB Vacuum Circuit Breaker 12KV

Country/Region china
City & Province zhejiang
Categories Battery Chargers
InquireNow

Product Details

Factory insulated Fixed 630A VS1 vcb Vacuum Circuit Breaker

 

Intorduction:

 

It is an indoor switchgear with three-phase AC 50Hz rated voltage of 12KV power system. It is used as protection and control unit for power equipment and industrial and mining enterprises. Applicable to places that require frequent operation at rated operating current, or multiple times to break short-circuit current.

The circuit breaker adopts an integrated design of the operating mechanism and the circuit breaker body, and can be used as a fixed installation unit, or can be equipped with a special propulsion mechanism to form a hand truck unit.

Features: small size, light weight, suitable for frequent operation

Main structure: vacuum interrupter, electromagnetic or spring operating mechanism, bracket and other components.

The main technical parameters:

NOItemUnitsTechnical parameters
1Rated voltageKV12
2Rated short-duration power frequency withstand voltage42/48(Interphase, ground/fracture)
3Rated lightning impulse withstand voltage42/48(Interphase, ground/fracture)
4Rated frequencyHz50
5Rated currentA630 1250

630 1250 1600

2000 2500 3150

630 1250 1600

2000 2500 3150

6Rated short-circuit breaking currentKA20/2531.540
7Rated short-time withstand voltage20/2531.540
8Rated short circuit durationS4
9Rated peak withstand currentKA50/6380100
10Rated short circuit closing current50/6380100
11Secondary circuit power frequency withstand voltage (1min) 

 

2000

12Rated single / back to back capacitor group breaking currentA630/400(40kA:800/400)
13Rated capacitor bank closing current 12.5 (frequency is not greater than)
14Mechanical lifeKA20000
15Rated current breaking times (electrical life)20000
16Rated short circuit current breaking timestimes50(40KA≤30)
17Dynamic and static contacts allow wear cumulative thicknessmm3
18Energy storage times≤10
19Contact opening distance

mm

 

11±1
20Overtravel3.5±0.5
21Contact closing bounce time

ms

 

≤2(40KA≤3)
22Three-phase split/closed period≤2
23Average opening speed (contacts are separated by -8mm)

m/s

 

1.2±0.2
24Main conductive loop resistance0.6±0.2
25Main conductive loop resistanceμΩ

≤50(630A)≤45(1250A)

≤40 (1600,2000A)≤35 (2500A or more)

26Rated operation sequence 0-0.3s-Co-180s-Co

 


Hot Products
 

 

Certifications

 

Company Profile

 

Our Advantages

 

Contact Us

Contact us

 

Hot Products

ZN63 3 phase trolley draw-out AC 10kV 11kV 12kV VS1 VCB Vacuum Circuit Breaker Products VCB-12 ...
Eberry Zn63a-12 12kv 630a Withdraw VCB Vacuum Circuit Breaker Intorduction: It is an indoor ...
Factory insulated Fixed 630A VS1 vcb Vacuum Circuit Breaker Intorduction: It is an indoor switchgear ...
High Voltage Electric supplier VBI-24 Vacuum Circuit Breaker vcb 24kv lateral poles for indoor ...
Eberry ERM1 1p 2p 3p 4p series micro Moulded Case circuit breaker Mini Circuit Breakers • Applicatio...
2P 800 Volt DC MCCB for Moulded Case Circuit Breaker Mini Circuit Breaker #detail_decorate_root ...