Home Companies Guangzhou Rongtao Medical Tech LTD.

Toshiba Aplio 300 Ultrasound Repair Service Report Error BSM31-5629

Guangzhou Rongtao Medical Tech LTD.

Contact Us

[China] country

Trade Verify

Address: Room 1705,Office Building B1,Wanda Plaza,No.2707,Kaichuang Road,Guangzhou,Guangdong,China

Contact name:MileyZhu

Inquir Now

Guangzhou Rongtao Medical Tech LTD.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Toshiba Aplio 300 Ultrasound Repair Service Report Error BSM31-5629

Country/Region china
City & Province guangzhou guangdong
InquireNow

Product Details

 

Toshiba Aplio 300 Ultrasound Repair Service Report Error

 

1. Repair time: 2-4 days
2. Warranty: 60 days
3. Fault phenomenon:
Report Error

 

Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range.

 

 

Other ultrasound parts related to Toshiba  that we can offer:

 

BrandCompatible SystemDescription
ToshibaFamio 5 (SSA-510A)TFT board BSM31-5629
ToshibaFamio 8 SSA-530APCB board I/O TSB1-20-20226
ToshibaFamio 8 SSA-530ACPU board BSM31-5409E* B
ToshibaFamio 8 SSA-530Acontrol panel TSB1-20-20212
ToshibaFamio 8 SSA-530ATI board PM30-26840D BSM31-0369
ToshibaFamio 8 SSA-530Amonitor
ToshibaNemio SSA-550AA03 SWRG 2 power board BSM31-3063
ToshibaNemio SSA-550AA70 SYSC 1 board BSM31-3112
ToshibaNemio SSA-550AA07 HVPS 2 Assy BSM31-3069
ToshibaNemio SSA-550AA36 PSEL 3 TI board BSM31-3092
ToshibaNemio SSA-550AA10-1 CPCT BSM31-3070
ToshibaNemio SSA-550AA56 CFPR 2 BSM31-3708
ToshibaNemio SSA-550ATI board BSM31-3888
ToshibaNemio XG SSA-580AA45 FERX 2H400510-3 BSM31-6415
ToshibaNemio XG SSA-580Ahard disk version 3.7.0 and 2.0.0
ToshibaXario SSA-660Amonitor
ToshibaXario 100track board BSM34-0638
ToshibaXario 200numeric keyboard N860-7662-T759
ToshibaAplio XV SSA-770Amainboard bsm31-7083e
ToshibaAplio XV SSA-770AAC/DC power board BSM31-3739-D
ToshibaAplio XV SSA-770ALCD
ToshibaAplio XG SSA-790ALCD BSM31-7129-05
ToshibaAplioAC/DC power board BSM31-2013E-G
ToshibaApliocontrol panel N368--6305
ToshibaAplioCB board BSM31-4427
ToshibaAplio 400/Aplio 500track board BSM34-1630
ToshibaAplio 400LCD monitor BSM31-8627E
ToshibaAplio 500RX board ywm2056*a
ToshibaAplio 500monitor BSM34-3255

 

 

 

 

Importance of maintaining ultrasound machine

 

Paying attention to preventive maintenance is the basic requirement of medical equipment engineers and technicians. Perform regular checks on equipment to ensure safe and effective operation of equipment, reduce downtime and save maintenance costs. Eliminate minor faults and avoid causing major faults to affect the normal operation of the hospital. Attention should be paid to any abnormality that occurs during the operation of the equipment. Sometimes a small abnormal phenomenon may be a precursor to a failure. If it is not checked, it may cause a greater failure and bring unnecessary losses to the hospital. Do not let the equipment work with faulty. Do not wait until the equipment is completely paralyzed before repairing. Routine maintenance can extend the service life of the equipment and improve economic efficiency.

 

 

The solution of dealing with ultrasonic image interference

 

1. Probe interference: replace the probe

2. Equipment interference: replace the power supply or internal boards

3. External interference:

(1) Workstation interference: it is recommended to add several magnetic rings to the video cable, if it is not work, replace the ATX power supply, or add a filter to the host power input.

(2) Power input interference: add several magnetic rings to the power line.

 

If the above methods do not work, just try the method of eliminating the equipotentiality

, adding a shielding cloth on the bed, and connect a wire to the ground strap of the machine.

 

 

 

Precautions for Maintenance

 

Before delivery, we'd like to confirm the below details of your defective ultrasonic board.

 

Have your board ever repaired? ( Better to be never repaired)

Is the board original in complete condition?

What's the detailed faults? ( Send me fault description, fault image or video)

 

Your answers will help our repair engineers team to prejudge whether it's repairable.

 

Hot Products

Ultrasound Transducer Repair Service GE RIC5-9-D Repair 4D Replace Dome Model: GE RIC5-9-D Fault ...
Ultrasound Transducer Repair Service GE RM6C 4D Maintenance Model: GE RM6C Fault Phenomenon: 4D ...
GE Logiq E9 Ultrasound Machine Repair Displays Virtual Image Replace Power Supply 1. Repair time: 2...
GE Logiq S6 Ultrasound Machine Repair Displays Virtual Plot And No Echo Zone 1. Repair time: 2-4 ...
Toshiba Aplio 300 Ultrasound Repair Service Report Error 1. Repair time: 2-4 days 2. Warranty: 60 ...
EPIQ 7 Report Error 227 Ultrasound Machine Repair Replace ACB Board 1. Repair time: 2-4 days 2. ...