Results forultrasound biopsy needle guide for ge transducerfrom 6203 Products.
|
Toshiba Aplio 300 Ultrasound Transducer Repair Toshiba Aplio 300 System Reports Error The parts with high failure rate&available in stock of this machine: 1.Motherboard (BV board)...
|
|
|
|
GE M5Sc-D Single-Crystal Matrix Array Ultrasound Probe 1.Type: Matrix 2.Frequency: 1.5-4.6 MHz 3.Compatible system: Vivid E9, Vivid S70, Vivid e95, Vivid e90 4.Application: Cardiac...
|
|
|
|
GE RAB4-8-D Wideband Curved Transducer Convex Array Ultrasound Probe Medical Scanner 1. Type: curved array 2. Frequency: 2-8 MHz 3. Compatible system: logiq e9/voluson e6/voluson ...
|
|
|
|
Ultrasound Transducer Probe GE 4C-D Convex Array Medical Equipment GE 4C-D Convex Array abdominal transducer 1. Type: convex array 2. Frequency: 1.6-6.0 MHz 3. Compatible system: ...
|
|
|
|
GE 3SC-RS Phased Array Ultrasound Transducer 1.Type:phased array 2.Compatible system: Logic V5, Logiq e, Logiq i, Logiq S8, Vivid e 3.Application: Vascular, Small Parts, Abdominal, ...
|
|
|
|
GE RIC5-9A-RS 3D 4D Endocavity Ultrasound Transducer Maintenance Dome and Crystal Array Replacement Model: GE RIC5-9A-RS Fault Phenomenon: 4D is broken; image missing, the crystal ...
|
|
|
|
GE RIC5-9-D 3D 4D Endovaginal Ultrasound Transducer Maintenance Repair 4D and Dome Replacement Model: GE RIC5-9-D Fault Phenomenon: 4D does not work Suggestion: Repair 4D, replace ...
|
|
|
|
GE RIC6-12-D Ultrasound Transducer Probe 4D Maintenance Model: GE RIC6-12-D Fault Phenomenon: 1. The cable is aging and hard. 2. The whole probe is aging. 3. 4D does not work. 4. ...
|
|
|
|
GE RAB2-6-RS Ultrasound Transducer Crystal Array Replacement 4D and Cable Repair Model: GE RAB2-6-RS Fault Phenomenon: Large missing images, aging and wrinkled cables, there is ...
|
|
|
|
GE RIC6-12-D Ultrasound Transducer Dome Replacement and 4D Maintenance Model: GE RIC6-12-D Fault Phenomenon: 4D error report, the Dome is off, the image and cable can be detected ...
|
|
|
|
GE L4-12T-RS Ultrasound Transducer Lens Replacement Model: GE L4-12-RS Fault Phenomenon: Cable and strain relief are aging, lens bubbling. Maintenance Plan: Replace lens (the ...
|
|
|
|
GE M5SC-D Ultrasound Transducer Crystal Array Replacement Cable and Strain Relief Repair Model: GE M5SC-D Fault Phenomenon: Cable and strain relief are aging, lens bubbling. ...
|
|
|
|
GE RAB4-8-D Convex Ultrasound Transducer 4D Repair and Dome Replacement Model: GE RAB4-8-D Fault Phenomenon: The dome is damaged and the oil leaks, and the 4D error is reported. ...
|
|
|
|
GE 8C-RS Micro Convex Ultrasound Transducer Cable and Crystal Array Replacement Model: GE 8C-RS Fault Phenomenon: The lens is damaged, the cable is yellow and aging, the image on ...
|
|
|
|
GE 4C-RS Convex Probe Ultrasound Transducer Lens Replacement Model: GE 4C-RS Fault Phenomenon: The cable is deformed, the image on the machine has dark shadow, and the lens is ...
|
|
|
|
GE RIC5-9A-RS Ultrasound Transducer Crystal Array and Dome Replacement 4D and Circuit Maintenance Model: GE RIC5-9A-RS Fault Phenomenon: The dome leaks oil, the 4D does not work, ...
|
|
|
|
4D Probe Maintenance GE RAB4-8-D Ultrasound Transducer Dome Replacement Model: GE RAB4-8-D Fault Phenomenon: The Dome is damaged and leaking oil, no other abnormalities Suggestion: ...
|
|
|
|
GE RIC5-9A-RS Ultrasound Transducer Crystal Array and Dome Replacement 4D and Circuit Maintenance Model: GE RIC5-9A-RS Fault Phenomenon: 4D error, and the image is missing. ...
|
|
|
|
Probe Maintenance for GE 4C Ultrasound Transducer Lens Replacement Model: GE 4C Fault Phenomenon: The cable and strain relief are aging, the image on the computer has dark shadows, ...
|
|
|
|
Probe Maintenance for GE 8C-RS Ultrasound Transducer Lens Replacement Model: GE 8C-RS Fault Phenomenon: The cable and strain relief are aging, the image on the computer has dark ...
|
|
|
You may also be interested in :