White Type 1 Surge Protection Device SPD Integral Structure Iimp 12.5kA

 

Uc(maximum continuous operating voltage)385V
Iimp(impulse discharge current for class I test)12.5kA
In(nominal discharge current for class II test)25kA
Up(voltage protection level)≤2.0kv
response time≤100ns
Signal deterioration indicationred: replace
green:ok
Housing Materialthermoplastic material
Housing self-extinguishing classUL94_V0
Temperature range-40℃+80℃
humidity range≤95%
Elevational≤3000m
Method of connecting wiremultiple
(Connect In Parallel )
Thread Dimensions6mm2~35mm2
Mounting method35mm standard rail installation
IP(degree of protection of enclosure)IP20
Remote communicationcan add
RS485 communicationcan add

 
 
Product features:
Switching type high energy SPD. It is mainly used in the first level lightning protection of power supply system below 400V.
Large discharge energy, fast response time, large flow capacity, residual voltage is lower .
Modular design, lightning protection module is suitable for different power grid system, easy to replace, beautiful appearance.
Imported high energy graphite, stable performance, safe use. No leakage current, no continuation current.
2 years quality guarantee, lifetime free technical support.
Optional communication alarm interface, external RS485 communication interface
 
set up method
1. The power supply shall be connected with multi-strand copper wires of no less than 6mm2, and the grounding wires shall be multi-strand copper wires of no less than 10mm. The connection line should be as short, straight and thick as possible.
2. The front end of lightning protection device should be connected in series with appropriate surge special circuit breaker(SCB), fuse or circuit breaker.
 
Installation precautions:
1, must be disconnected from the power supply when installed, it is strictly prohibited to live operation, the connecting wire must meet the requirements.
2, check the SPD works or not after the lighning protection device installed .
3, lightning protection device no need special maintenance, just regularly check whether the connection is loose, the state indication is normal
 
Special
accept OEM, can be customized according to customer requirements.
 
 

























Hot Products

500V 800V 1000V photovoltaic surge protective device SPD HJH2-PV SPD NameDC Power Supply LightningDC ...
760V 27mm Surge Protection Device With 25kA Current Capacity OBV-I25: Uc(maximum continuous ...
Mature Technology 40kA Surge Protection Device Traditional Products OBV-II40-3 data: Uc(maximum ...
White Type 1 Surge Protection Device SPD Integral Structure Iimp 12.5kA Uc(maximum continuous ...
Up 1.8kV Imax 40kA SPD Surge Protection Device In PA66 And PBT Combined Material Uc(maximum ...
Imax 65kA Surge Protection Device With Four PE Location Preventing Module Vibration Uc(maximum ...