Home Companies Guangdong Uchi Technology Co.,Ltd

AC 180V Surge Box Protector Imax 200kA Wire Connection 350x260x130mm

Guangdong Uchi Technology Co.,Ltd
Active Member

Contact Us

[China] country

Address: Floor 4, NO.25-29,Power Station Road, Xihu , Shilong Town , Dongguan 523325, China.

Contact name:Amy

Inquir Now

Guangdong Uchi Technology Co.,Ltd

AC 180V Surge Box Protector Imax 200kA Wire Connection 350x260x130mm

Country/Region china
City & Province dongguan
Categories Solar Chargers
InquireNow

Product Details

AC 180V/320V Power Lightning Protection Box For Solar Power System , Industrial

 

 

Product Category(GB/IEC) Class I+II/ Type 1+2
Protection mode Full protection mode
Product technologies ESG technology (pre-stage) + VTD technology (post-stage); LC filter technology; thermal trip technology; built-in series overcurrent protection
Applicable power distribution systemUn120/208V to 127/220V Three-phase (TN/TT)220/380V to 277/480V Three-phase (TN/TT)
Maximum sustainable working voltage (AC)Uc180V320V
Rated load currentIL400A
Nominal discharge currentIn50kA (8/20μs)
Pre-stage surge protection capabilityL-N Iimp: 50kA (10/350μs), Imax: 150kA (8/20μs)
N-PE Iimp: 100kA (10/350μs), Imax: 200kA (8/20μs)
Post-level surge protection capabilityL-NImax50kA (8/20μs)
Surge discharge capacity (each phase)Imax200kA (8/20μs)
Voltage protection levelL-N@6kV/3kAVPR≤ 0.4kV≤ 0.5kV
L-N@In(50kA, 8/20μs)Up≤ 0.8kV≤ 1.0kV
N-PE@1.2/50μsUp≤ 1.0kV≤ 1.5kV
Working currentIPE<0.1mA
Pressure drop < 2V,At rated load current
Temporary overvoltage characteristics-withstand modeUtov230V/120min440V/120min

 

Scope of application:


The second-level lightning protection box is mainly installed in the floor power distribution, computer room power distribution and other environments, as the second-level lightning protection of the power distribution system, discharges the remaining surge, and cooperates with the first-level lightning protection box to meet the lightning protection acceptance Requirements and protection needs.

 

The main parameters:


Maximum continuous working voltage Uc: 385VAC
Nominal discharge current In(8/20μs): 20kA or 40kA
Maximum discharge current Imax (8/20μs): 40kA or 80kA
Protection level Up: 1.8kV or 2.1kV
Protection mode: three-phase 4P, single-phase 2P
Product size: 350*260*130mm

 

Product Description:


Adopting Class II SPD to combine “3+1” circuit, protecting low voltage equipment from surge damages, applied in TT system, designed according to IEC61643-1/GB 18802.1
Main character:
1. Green light indicates normal and red light indicates fault for operation

2. Built-in circuit breaker, and thermal disconnection device, when the fault occurred, the thermal disconnection device will cut off the SPD from the power net, the green window will change
3. Impulse counter function, recording the lightning events
4. External wiring terminal, easy for connection, suitable for indoor application

 

Type BT 5L CM 275/40 4PBT 5L CM 385/40 4PBT 5L CM 275/40 3+1BT 5L CM 385/40 3+1
Order No. 840 883840 887840 884840 888
Norminal a.c. voltageUN230V/400V230V/400V230V/400V230V/400V
Rated voltage (max. continuous a.c voltage) L/NUc275V385V275V385V
Rated voltage (max. continuous a.c voltage) N/PEUc275V385V255V255V
Nominal discharge current (8/20µs) L/NIn20KA20KA20KA20KA
Nominal discharge current (8/20µs) N/PEIn20KA20KA40KA40KA
Max. discharge current (8/20µs) L/NImax40KA40KA40KA40KA
Max. discharge current (8/20µs) N/PEImax40KA40KA65KA65KA
Voltage protection level L/NUp≤1.25KV≤1.8KV≤1.25KV≤1.8KV
Voltage protection level N/PEUp≤1.25KV≤1.8KV≤1.5KV≤1.5KV
Follow current extinguishing capability at Uc (N/E)IL  100Arms100Arms
Operating temperature range -40℃…+80℃
Cross-sectional area 25mm2 solid/35mm2 flexible
Enclosure material black metal housing (die-casting Aluminum)
Test standards YD/T 1235.1; GB 18802.1; IEC 61643-1
Certification CE (LVD, EMC)

 


 

Hot Products

500V 800V 1000V photovoltaic surge protective device SPD HJH2-PV SPD NameDC Power Supply LightningDC ...
760V 27mm Surge Protection Device With 25kA Current Capacity OBV-I25: Uc(maximum continuous ...
Mature Technology 40kA Surge Protection Device Traditional Products OBV-II40-3 data: Uc(maximum ...
White Type 1 Surge Protection Device SPD Integral Structure Iimp 12.5kA Uc(maximum continuous ...
Up 1.8kV Imax 40kA SPD Surge Protection Device In PA66 And PBT Combined Material Uc(maximum ...
Imax 65kA Surge Protection Device With Four PE Location Preventing Module Vibration Uc(maximum ...